{"product_id":"allen-bradley-1747-l514-slc-500-fixed-hardware-controller-processor","title":"Allen-Bradley 1747-L514 SLC 500 Fixed Hardware Controller Processor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1747-L514 is a reliable controller processor from the well-established SLC 500 modular hardware family. Engineered for small to medium-scale industrial automation tasks, this processor delivers dependable execution speed and flexible communication capabilities to handle demanding discrete control requirements. It integrates seamlessly into standard SLC 500 modular chassis configurations, providing plant operators with a robust platform for machine and process automation.\u003c\/p\u003e\n\u003cp\u003eDesigned to support structured programming via RSLogix 500, the 1747-L514 facilitates straightforward logic development, troubleshooting, and system maintenance. The unit incorporates onboard DH-485 communication interfaces for network connectivity and programming support, making it an enduring solution for legacy system upgrades and discrete manufacturing applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eModular SLC 500 controller processor designed for small and medium industrial control applications\u003c\/li\u003e\n  \u003cli\u003eSupports up to 7,880 maximum digital I\/O points across expanded architectures\u003c\/li\u003e\n  \u003cli\u003eCompatible with a maximum of 3 local chassis and 30 total local slots\u003c\/li\u003e\n  \u003cli\u003eOnboard DH-485 communication channel for programming and slave device connectivity\u003c\/li\u003e\n  \u003cli\u003eFlash\/EEPROM memory module compatibility for secure user program backup\u003c\/li\u003e\n  \u003cli\u003eProgram execution supported by RSLogix 500 programming software\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDiscrete manufacturing and assembly lines\u003c\/li\u003e\n  \u003cli\u003ePackaging and material handling systems\u003c\/li\u003e\n  \u003cli\u003ePumping stations and water treatment control panels\u003c\/li\u003e\n  \u003cli\u003eOEM machinery automation and legacy system retrofits\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003e1747-L514\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Family\u003c\/td\u003e\n      \u003ctd\u003eSLC 500\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBackplane Current Draw\u003c\/td\u003e\n      \u003ctd\u003e90 mA at 5 VDC; 0 mA at 24 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCommunication Port\u003c\/td\u003e\n      \u003ctd\u003eDH-485 (Channel 0)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Digital I\/O Capacity\u003c\/td\u003e\n      \u003ctd\u003e7,880 max digital I\/O\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eChassis Capacity\u003c\/td\u003e\n      \u003ctd\u003e3 local chassis \/ 30 local slots max\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProgramming Software\u003c\/td\u003e\n      \u003ctd\u003eRSLogix 500\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBit Execution Time (XIC)\u003c\/td\u003e\n      \u003ctd\u003e4 microseconds\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTypical Scan Time\u003c\/td\u003e\n      \u003ctd\u003e8 ms per K\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eAlways disconnect power to the SLC 500 chassis before installing or removing the 1747-L514 processor module to prevent equipment damage or personal injury. Ensure the module is firmly seated in the designated slot and secured with its retaining screws. The controller battery may be replaced while system power is active, provided standard electrostatic discharge (ESD) precautions are observed.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53770308682091,"sku":"1747-L514","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1747-L514_1200x1200_1336453c-44fb-4118-ad14-715ca64160f9.jpg?v=1787740939","url":"https:\/\/www.plcprotech.com\/products\/allen-bradley-1747-l514-slc-500-fixed-hardware-controller-processor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}