{"product_id":"allen-bradley-1756-iv16-controllogix-digital-dc-input-module","title":"Allen-Bradley 1756-IV16 ControlLogix Digital DC Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen Bradley 1756-IV16\u003c\/strong\u003e is a ControlLogix digital DC sourcing input module. Designed for compatibility with the ControlLogix 1756 chassis system, this module receives discrete signal inputs from field devices and transfers input status to the system backplane. It requires a removable terminal block housing (RTB)—either the 1756-TBNH or 1756-TBSH—prior to mounting into the chassis. The \u003cstrong\u003e1756-IV16\u003c\/strong\u003e provides 16 sourcing input channels configured in 2 groups of 8 points each, operating across a nominal supply voltage of 12\/24V DC.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 digital sourcing inputs organized into two groups of 8 points.\u003c\/li\u003e\n\u003cli\u003eOperating DC voltage range from 10V DC to 30V DC.\u003c\/li\u003e\n\u003cli\u003eConfigurable off-to-on hardware input delay plus user-selectable digital filter options.\u003c\/li\u003e\n\u003cli\u003eOptical isolation rating up to 250V continuous.\u003c\/li\u003e\n\u003cli\u003eCompatible with 1756-TBNH and 1756-TBSH removable terminal blocks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFactory automation discrete sensing and position detection.\u003c\/li\u003e\n\u003cli\u003eMachine tool limit switch and proximity switch monitoring.\u003c\/li\u003e\n\u003cli\u003eMaterial handling equipment status feedback.\u003c\/li\u003e\n\u003cli\u003eProcess control interlock and discrete event monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControlLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-IV16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUPC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e612598264346\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital DC Sourcing Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 (8 points per group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\/24V DC source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10...30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff-State Voltage (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff-State Current (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-State Current (Min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mA @ 10V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-State Current (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mA @ 30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 kohm @ 30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Delay Time (Off to On)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardware delay: 280 us nom \/ 1 ms max + filter time (0 ms, 1 ms, or 2 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Delay Time (On to Off)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardware delay: 540 us nom \/ 2 ms max + filter time (1 ms, 2 ms, 9 ms, or 18 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current @ 5.1V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current @ 24V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Backplane Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.61 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.1 W @ 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.47 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250V continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Terminal Block Housing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-TBNH, 1756-TBSH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.09 kg (0.19 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure system power and backplane power are removed before installing or removing the module.\u003c\/li\u003e\n\u003cli\u003eSecurely wire field devices to the compatible 1756-TBNH or 1756-TBSH Removable Terminal Block (RTB) according to standard industrial wiring practices.\u003c\/li\u003e\n\u003cli\u003eAlign the module with the chassis slot guides and push firmly until the module latches into the ControlLogix backplane.\u003c\/li\u003e\n\u003cli\u003eRoute signal wiring away from high-voltage AC lines and high-frequency noise sources to mitigate EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eMaintain proper panel ventilation to prevent operating ambient temperatures from exceeding 60 degC.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695185228139,"sku":"1756-IV16","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-iv16-digital-input-module-vdmlvg5ogjl_a7c6640c-191f-4fed-b2cc-ca804f5e0a19.jpg?v=1766114432","url":"https:\/\/www.plcprotech.com\/products\/allen-bradley-1756-iv16-controllogix-digital-dc-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}