{"product_id":"allen-bradley-1756-l63-controllogix-8-mb-memory-controller","title":"Allen-Bradley 1756-L63 ControlLogix 8 MB Memory Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1756-L63\u003c\/strong\u003e ControlLogix controller is a programmable automation controller designed for industrial automation systems. It features \u003cstrong\u003e8 MB\u003c\/strong\u003e of data and logic memory. The \u003cstrong\u003e1756-L63\u003c\/strong\u003e executes control logic, communicates with I\/O configuration devices, and handles Message (MSG) instructions along with OPC\/DDE tags via RSLinx software. Nonvolatile memory capabilities are supported via an optional 1784-CF64 Industrial CompactFlash card. Serial RS-232 communications are integrated via an onboard point-to-point interface. The module installs into any slot of a ControlLogix chassis.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 MB\u003c\/strong\u003e memory capacity for data and logic execution\u003c\/li\u003e\n\u003cli\u003eOptional nonvolatile memory storage using a 1784-CF64 Industrial CompactFlash card\u003c\/li\u003e\n\u003cli\u003eIntegrated RS-232 serial port interface for programming and communications\u003c\/li\u003e\n\u003cli\u003eDynamic status indication LEDs for RUN, I\/O, FORCE, RS232, BAT, and OK operating modes\u003c\/li\u003e\n\u003cli\u003eThree-position front keyswitch for PROG, REM, and RUN mode selection\u003c\/li\u003e\n\u003cli\u003eSupport for chassis-based insertion and removal under backplane power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial Process Control Systems\u003c\/li\u003e\n\u003cli\u003eFactory Automation and Machine Control\u003c\/li\u003e\n\u003cli\u003eDistributed I\/O Architectures\u003c\/li\u003e\n\u003cli\u003eMulti-Controller Chassis Configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData and Logic Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current (5.1V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current (24V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.9 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32 kg (11.3 oz) (Series A) \/ 0.35 kg (12.4 oz) (Series B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC (32 to 140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 degC (-40 to 185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration (Operating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 g @ 10 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock (Operating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock (Nonoperating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEmissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCISPR 11: Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESD Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV contact discharges, 8 kV air discharges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadiated RF Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10V\/m (80 to 2000 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEFT\/B Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±4 kV at 5 kHz on communications ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Transient Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±2 kV line earth (CM) on communications ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConducted RF Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10V rms (150 kHz to 80 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30V (continuous), Basic Insulation Type, RS232 to system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplacement Battery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-BA1 (Series A) \/ 1756-BA2 (Series B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramming Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-CP3 or 1747-CP3 serial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Type Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePin 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCD (Carrier Detect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePin 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRXD (Receive Data)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePin 3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTXD (Transmit Data)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePin 4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDTR (Data Terminal Ready)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePin 5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGND \/ COMMON (Signal Ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePin 6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDSR (Data Set Ready)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePin 7\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTS (Request To Send)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePin 8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCTS (Clear To Send)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePin 9\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/C (Not Connected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Must be installed in an open-style enclosure appropriate for specific environmental conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Wear a grounded wriststrap and avoid touching connectors, pins, or internal circuit components prior to handling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Mounting:\u003c\/strong\u003e Align the circuit board with top and bottom guides inside the chassis, sliding the controller until top and bottom latches lock securely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Cable:\u003c\/strong\u003e Limit custom-built RS-232 serial cables to a maximum distance of 15.2 m (50 ft) and connect shielding to both ends.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Location:\u003c\/strong\u003e Do not connect or disconnect cables, batteries, or CompactFlash cards unless power is removed or the area is known to be nonhazardous.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ec-UL-us:\u003c\/strong\u003e UL Listed Industrial Control Equipment for US and Canada (UL File E65584)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ec-UL-us Class I Div 2:\u003c\/strong\u003e Certified for Class I Division 2 Groups A, B, C, D Hazardous Locations (UL File E194810)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e CSA Certified Process Control Equipment (File LR54689C) and Class I Division 2 (File LR69960C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFM:\u003c\/strong\u003e FM Approved Equipment for Class I Division 2 Groups A, B, C, D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Union 2004\/108\/IEC EMC Directive (EN 61326-1, EN 61000-6-2, EN 61000-6-4, EN 61131-2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC-Tick:\u003c\/strong\u003e Compliant with AS\/NZS CISPR 11 Industrial Emissions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEEx \/ ATEX:\u003c\/strong\u003e European Union 94\/9\/EC ATEX Directive (EN 60079-15, Zone 2)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695179460971,"sku":"1756-L63","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-l63-controllogix-standard-controller-i3sotcyhilk_450ec930-f0ac-4d71-890b-5973335af23d.jpg?v=1766114247","url":"https:\/\/www.plcprotech.com\/products\/allen-bradley-1756-l63-controllogix-8-mb-memory-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}