{"product_id":"allen-bradley-1756-l72-controllogix-5570-4-mb-controller","title":"Allen-Bradley 1756-L72 ControlLogix 5570 4 MB Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e1756-L72\u003c\/strong\u003e is a \u003cstrong\u003eControlLogix 5570 controller\u003c\/strong\u003e for logic execution, I\/O coordination, motion control, and system communication. It provides 4 MB of user memory and 0.98 MB of dedicated I\/O memory.\u003c\/p\u003e\n\u003cp\u003eThe controller processes local and remote I\/O through the ControlLogix chassis and installed communication modules. It supports digital, analog, specialty, and motion modules without integrated onboard I\/O.\u003c\/p\u003e\n\u003cp\u003eA front-panel USB port provides temporary programming, configuration, firmware update, and online editing access. The controller has no embedded industrial network port. Network communication requires a compatible module installed in the local chassis.\u003c\/p\u003e\n\u003cp\u003eNonvolatile storage uses a removable Secure Digital card. A capacitor-based energy storage module supports memory retention and WallClockTime operation without a replaceable lithium battery.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eControlLogix 5570 architecture for coordinated logic, I\/O, and motion applications\u003c\/li\u003e\n\u003cli\u003eContinuous, periodic, and event task execution\u003c\/li\u003e\n\u003cli\u003eRelay ladder, structured text, function block, and sequential function chart programming\u003c\/li\u003e\n\u003cli\u003eCommunication through modular ControlLogix network interfaces\u003c\/li\u003e\n\u003cli\u003eController redundancy support\u003c\/li\u003e\n\u003cli\u003eIntegrated motion support through EtherNet\/IP, SERCOS, and analog motion interfaces\u003c\/li\u003e\n\u003cli\u003eSecure Digital project storage and automatic fault-data capture\u003c\/li\u003e\n\u003cli\u003eCapacitor-based energy storage instead of battery-backed memory\u003c\/li\u003e\n\u003cli\u003eFour-character scrolling status display\u003c\/li\u003e\n\u003cli\u003eRUN, FORCE, SD, and OK status indicators\u003c\/li\u003e\n\u003cli\u003eDouble Data Rate backplane communication with supported modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachine and production line control\u003c\/li\u003e\n\u003cli\u003eProcess control systems\u003c\/li\u003e\n\u003cli\u003eDistributed I\/O coordination\u003c\/li\u003e\n\u003cli\u003eIntegrated motion applications\u003c\/li\u003e\n\u003cli\u003eMaterial handling systems\u003c\/li\u003e\n\u003cli\u003ePackaging and assembly equipment\u003c\/li\u003e\n\u003cli\u003eController redundancy systems\u003c\/li\u003e\n\u003cli\u003ePlant-wide communication architectures\u003c\/li\u003e\n\u003cli\u003eSupervisory control and data acquisition\u003c\/li\u003e\n\u003cli\u003eMulti-controller automation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eInformation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e1756-L72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnique Product Identifier\u003c\/td\u003e\n\u003ctd\u003e1756-L72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e612598876020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Description\u003c\/td\u003e\n\u003ctd\u003eControlLogix 5570 Controller with 4 MB Memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEstimated Lead Time\u003c\/td\u003e\n\u003ctd\u003e5 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Status\u003c\/td\u003e\n\u003ctd\u003eActive Mature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eMultiple countries, based on manufacturing location\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eIncluded Components\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1756-ESMCAP\u003c\/td\u003e\n\u003ctd\u003eCapacitor-based energy storage module, installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1784-SD1\u003c\/td\u003e\n\u003ctd\u003e1 GB Secure Digital card, installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1747-KY\u003c\/td\u003e\n\u003ctd\u003eController key\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral and Memory\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e1756-L72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Family\u003c\/td\u003e\n\u003ctd\u003eControlLogix 5570\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProgrammable Automation Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e4 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Memory\u003c\/td\u003e\n\u003ctd\u003e0.98 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonvolatile Storage\u003c\/td\u003e\n\u003ctd\u003e1 GB Secure Digital card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstalled SD Card\u003c\/td\u003e\n\u003ctd\u003e1784-SD1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmbedded Network Port\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Display\u003c\/td\u003e\n\u003ctd\u003eFour-character scrolling display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eRUN, FORCE, SD, and OK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eTask and Programming Capacity\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Tasks\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTask Types\u003c\/td\u003e\n\u003ctd\u003eContinuous, periodic, and event\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrograms per Task before Version 15.01\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrograms per Task from Version 15.01\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrograms per Task from Version 24.00\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Ladder Logic\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStructured Text\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction Block Diagram\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSequential Function Chart\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eI\/O and Control Capacity\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Digital I\/O\u003c\/td\u003e\n\u003ctd\u003e128,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Analog I\/O\u003c\/td\u003e\n\u003ctd\u003e4,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Total I\/O\u003c\/td\u003e\n\u003ctd\u003e128,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Controller Connections\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Redundancy\u003c\/td\u003e\n\u003ctd\u003eFull support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Motion\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP, SERCOS, and analog motion options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Motion Interfaces\u003c\/td\u003e\n\u003ctd\u003eEncoder input, LDT input, and SSI input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eCommunication\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-In Communication Port\u003c\/td\u003e\n\u003ctd\u003eOne USB port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Standard\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eType B receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Communication Rate\u003c\/td\u003e\n\u003ctd\u003eFull speed, 12 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Functions\u003c\/td\u003e\n\u003ctd\u003eProgramming, configuration, firmware updates, and online edits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEtherNet\/IP\u003c\/td\u003e\n\u003ctd\u003eSupported through a communication module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControlNet\u003c\/td\u003e\n\u003ctd\u003eSupported through a communication module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeviceNet\u003c\/td\u003e\n\u003ctd\u003eSupported through a communication module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Highway Plus\u003c\/td\u003e\n\u003ctd\u003eSupported through a communication module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote I\/O\u003c\/td\u003e\n\u003ctd\u003eSupported through a communication module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSERCOS\u003c\/td\u003e\n\u003ctd\u003eSupported through an interface module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThird-Party Networks\u003c\/td\u003e\n\u003ctd\u003eSupported through compatible communication modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnergy Storage\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Energy Storage Module\u003c\/td\u003e\n\u003ctd\u003e1756-ESMCAP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Storage Type\u003c\/td\u003e\n\u003ctd\u003eRemovable capacitor-based ESM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWallClockTime Hold-Up at 20 degC\u003c\/td\u003e\n\u003ctd\u003e12 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWallClockTime Hold-Up at 40 degC\u003c\/td\u003e\n\u003ctd\u003e10 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWallClockTime Hold-Up at 60 degC\u003c\/td\u003e\n\u003ctd\u003e7 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternative ESM without WallClockTime Backup\u003c\/td\u003e\n\u003ctd\u003e1756-ESMNSE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity ESM\u003c\/td\u003e\n\u003ctd\u003e1756-ESMNRM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Initial Charging Time\u003c\/td\u003e\n\u003ctd\u003e2 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eBackplane Power Requirements\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw at 1.2V DC\u003c\/td\u003e\n\u003ctd\u003e5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw at 5.1V DC\u003c\/td\u003e\n\u003ctd\u003e800 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e8.5 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e30V continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Type\u003c\/td\u003e\n\u003ctd\u003eBasic insulation, USB port-to-system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety Standard\u003c\/td\u003e\n\u003ctd\u003eIEC\/UL 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eMechanical Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Weight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg (0.55 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Width\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Location\u003c\/td\u003e\n\u003ctd\u003eChassis-based, any slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type Rating\u003c\/td\u003e\n\u003ctd\u003eNone, open-style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Code\u003c\/td\u003e\n\u003ctd\u003eT4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eSystem Compatibility\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Chassis\u003c\/td\u003e\n\u003ctd\u003e1756-A4, 1756-A7, 1756-A10, 1756-A13, and 1756-A17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal-Coated Chassis\u003c\/td\u003e\n\u003ctd\u003e1756-A4K, 1756-A7K, 1756-A10K, 1756-A13K, and 1756-A17K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard AC Power Supplies\u003c\/td\u003e\n\u003ctd\u003e1756-PA50, 1756-PA72, and 1756-PA75 families\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard DC Power Supplies\u003c\/td\u003e\n\u003ctd\u003e1756-PB50, 1756-PB72, 1756-PB75, 1756-PC75, and 1756-PH75 families\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant Power Supplies\u003c\/td\u003e\n\u003ctd\u003e1756-PA75R and 1756-PB75R families\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant Chassis Adapter\u003c\/td\u003e\n\u003ctd\u003e1756-PSCA2 or 1756-PSCA2K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0...60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonoperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40...+85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5...95%, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Standard\u003c\/td\u003e\n\u003ctd\u003eIEC 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Shock Standard\u003c\/td\u003e\n\u003ctd\u003eIEC 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonoperating Shock Standard\u003c\/td\u003e\n\u003ctd\u003eIEC 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissions Standard\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESD Immunity\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-4-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiated RF Immunity\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-4-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConducted RF Immunity\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-4-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Type B Port\u003c\/td\u003e\n\u003ctd\u003eTemporary local programming, configuration, firmware update, and online editing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecure Digital Card Slot\u003c\/td\u003e\n\u003ctd\u003eStores controller projects, firmware, and diagnostic fault information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControlLogix Backplane\u003c\/td\u003e\n\u003ctd\u003eConnects the controller to local I\/O and communication modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Storage Module Interface\u003c\/td\u003e\n\u003ctd\u003eAccepts the removable capacitor-based ESM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode Switch\u003c\/td\u003e\n\u003ctd\u003eSelects Run, Remote, or Program operating modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Display\u003c\/td\u003e\n\u003ctd\u003eReports firmware, project, SD card, ESM, and controller fault information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe USB cable must not exceed 3.0 m and must not contain hubs. The USB port is not intended for permanent communication.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the ControlLogix chassis and power supply before inserting the controller.\u003c\/li\u003e\n\u003cli\u003eMount the open-style controller inside a suitable industrial enclosure.\u003c\/li\u003e\n\u003cli\u003eObserve electrostatic discharge precautions during handling.\u003c\/li\u003e\n\u003cli\u003eWear an approved grounding wrist strap.\u003c\/li\u003e\n\u003cli\u003eAvoid touching connectors, pins, and internal circuit components.\u003c\/li\u003e\n\u003cli\u003eInstall the controller in any available compatible chassis slot.\u003c\/li\u003e\n\u003cli\u003eAlign the circuit board with the upper and lower chassis guides.\u003c\/li\u003e\n\u003cli\u003eSlide the controller into the chassis until it snaps into place.\u003c\/li\u003e\n\u003cli\u003eVerify that the controller sits flush with adjacent modules.\u003c\/li\u003e\n\u003cli\u003eRemove backplane power before installation in a hazardous location.\u003c\/li\u003e\n\u003cli\u003eLeave the Secure Digital card installed during normal operation.\u003c\/li\u003e\n\u003cli\u003eVerify that the SD indicator is off before removing the card.\u003c\/li\u003e\n\u003cli\u003eDo not insert or remove the SD card in an energized hazardous location.\u003c\/li\u003e\n\u003cli\u003eAllow the ESM to finish charging before removing controller power.\u003c\/li\u003e\n\u003cli\u003eConfirm that CHRG or ESM Charging is no longer displayed.\u003c\/li\u003e\n\u003cli\u003eDo not use the USB port in hazardous locations.\u003c\/li\u003e\n\u003cli\u003eLimit USB cable length to 3.0 m and do not use USB hubs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eCertifications apply when the corresponding marking appears on the product.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ec-UL-us\u003c\/td\u003e\n\u003ctd\u003eUL Listed Industrial Control Equipment for the United States and Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Locations\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 2, Groups A, B, C, and D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003ctd\u003eEU EMC Directive compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRCM\u003c\/td\u003e\n\u003ctd\u003eAustralian Radiocommunications Act compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX\u003c\/td\u003e\n\u003ctd\u003eII 3 G Ex ec IIC T4 Gc, UL 22 ATEX 2817X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIECEx\u003c\/td\u003e\n\u003ctd\u003eII 3 G Ex ec IIC T4 Gc, IECEx UL 22.0062X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUKEx\u003c\/td\u003e\n\u003ctd\u003eIncreased safety \"e\", UL22UKEX2601X, Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUKCA\u003c\/td\u003e\n\u003ctd\u003eUK EMC, explosive atmosphere, and restricted substance regulations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKC\u003c\/td\u003e\n\u003ctd\u003eKorean broadcasting and communications equipment registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCC\u003c\/td\u003e\n\u003ctd\u003eCCC 2020122309111998\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eIEC\/UL 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695172579691,"sku":"1756-L72","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-l72-controllogix-4-mb-controller-qghuecexrhm_ca057c7b-a888-48ea-9397-d33c761181f7.jpg?v=1766114094","url":"https:\/\/www.plcprotech.com\/products\/allen-bradley-1756-l72-controllogix-5570-4-mb-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}