{"product_id":"allen-bradley-1756-oa16i-controllogix-16-point-ac-isolated-output-module","title":"Allen-Bradley 1756-OA16I ControlLogix 16 Point AC Isolated Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1756-OA16I\u003c\/strong\u003e is a ControlLogix digital AC output module designed to control field-side industrial actuators, motor starters, and solenoids. Operating across a broad output voltage range of 74 to 265 V AC, the \u003cstrong\u003e1756-OA16I\u003c\/strong\u003e features 16 individually isolated channels to prevent cross-channel interference and ensure reliable system operation. Equipped with a 36-pin removable terminal block interface, this module integrates seamlessly into standard ControlLogix chassis architectures and supports minimum firmware revisions 1.0, 2.0, and 3.0 alongside Studio 5000 \/ RSLogix 5000 design software version V20 or higher.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 individually isolated output channels\u003c\/li\u003e\n\u003cli\u003eWide operating voltage range of 74 to 265 V AC\u003c\/li\u003e\n\u003cli\u003eHigh continuous channel-to-channel isolation rating of 250 V\u003c\/li\u003e\n\u003cli\u003e36-pin Removable Terminal Block (RTB) connection architecture\u003c\/li\u003e\n\u003cli\u003eCompatible with standard ControlLogix chassis and backplanes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndividual AC load switching and actuator control\u003c\/li\u003e\n\u003cli\u003eSolenoid valve and motor starter control\u003c\/li\u003e\n\u003cli\u003eIsolated field device interfacing in power distribution systems\u003c\/li\u003e\n\u003cli\u003eIndustrial process automation across diverse voltage domains\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-OA16I, 1756-OA16IK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUPC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e612598164516\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMalaysia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutputs \/ Number of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 individually isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePilot Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e74...265V AC, 47...63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage and Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 A per point @ 74...265V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Per Point, Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 A @ 30 C (86 F) linear derating\u003c\/p\u003e\n\u003cp\u003e1 A @ 60 C (140 F) linear derating\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Per Module, Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5 A @ 30 C (86 F) linear derating\u003c\/p\u003e\n\u003cp\u003e4 A @ 60 C (140 F) linear derating\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Current Per Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A for 43 ms per point, repeatable every 2 s @ 60 C (140 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Current, Min\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mA per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Delay Time (Off to On)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e9.3 ms @ 60 Hz\u003c\/p\u003e\n\u003cp\u003e11 ms @ 50 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Delay Time (On to Off)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e9.3 ms @ 60 Hz\u003c\/p\u003e\n\u003cp\u003e11 ms @ 50 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw @ 5.1V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw @ 24V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Backplane Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.59 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation, Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 W @ 60 C (140 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.76 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff-State Leakage Current, Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 mA per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-State Voltage Drop, Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1.5V peak @ 2 A\u003c\/p\u003e\n\u003cp\u003e6V peak @ load current \u0026lt; 50 mA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommutating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4 V\/us for loads \u0026gt; 50 mA\u003c\/p\u003e\n\u003cp\u003e0.2 V\/us for loads \u0026lt; 50 mA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScheduled Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSynchronization within 16.7 s max, reference to Coordinated System Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStates in Fault Mode Per Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHold last state, On or Off (Off is default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStates in Program Mode Per Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHold last state, On or Off (Off is default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250V continuous, basic insulation type, outputs-to-backplane, and output-to-output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInhibit Voltage, Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZero crossing 60V peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Module Firmware Revision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 \/ 2.0 \/ 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Design Software Revision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Keying\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic, software configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFusing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot protected. A fused IFM is recommended to help protect outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Terminal Block (RTB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-TBCH, 1756-TBS6H (36-pin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRTB Keying\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUser-defined mechanical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlot Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (open style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNorth American Temp Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 99.9009%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 39.1134%;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 60.5628%;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1134%;\"\u003e\u003cstrong\u003eTemperature, Operating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.5628%;\"\u003e0...60 C (32...140 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1134%;\"\u003e\u003cstrong\u003eTemperature, Surrounding Air, Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.5628%;\"\u003e60 C (140 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1134%;\"\u003e\u003cstrong\u003eTemperature, Nonoperating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.5628%;\"\u003e-40...+85 C (-40...+185 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1134%;\"\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.5628%;\"\u003e5...95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1134%;\"\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.5628%;\"\u003e2 g @ 10...500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1134%;\"\u003e\u003cstrong\u003eShock, Operating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.5628%;\"\u003e30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1134%;\"\u003e\u003cstrong\u003eShock, Nonoperating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.5628%;\"\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1134%;\"\u003e\u003cstrong\u003eEmissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.5628%;\"\u003eIEC 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1134%;\"\u003e\u003cstrong\u003eESD Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.5628%;\"\u003e\n\u003cp\u003e6 kV contact discharges\u003c\/p\u003e\n\u003cp\u003e8 kV air discharges\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1134%;\"\u003e\u003cstrong\u003eRadiated RF Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.5628%;\"\u003e\n\u003cp\u003e10V\/m with 1 kHz sine-wave 80% AM from 80...2000 MHz\u003c\/p\u003e\n\u003cp\u003e10V\/m with 200 Hz 50% Pulse 100% AM @ 900 MHz\u003c\/p\u003e\n\u003cp\u003e10V\/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz\u003c\/p\u003e\n\u003cp\u003e3V\/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1134%;\"\u003e\u003cstrong\u003eEFT\/B Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.5628%;\"\u003e±4 kV at 5 kHz on signal ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1134%;\"\u003e\u003cstrong\u003eSurge Transient Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.5628%;\"\u003e±1 kV line-line (DM) and ±2 kV line-earth (CM) on signal ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1134%;\"\u003e\u003cstrong\u003eConducted RF Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.5628%;\"\u003e10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1134%;\"\u003e\u003cstrong\u003eOscillatory Surge Withstand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.5628%;\"\u003e3 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 99.9009%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 19.1361%;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 80.5401%;\"\u003e\u003cstrong\u003eRating \/ Standards\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 19.1361%;\"\u003e\u003cstrong\u003eUL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80.5401%;\"\u003eUL Listed Industrial Control Equipment. See UL File E65584.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 19.1361%;\"\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80.5401%;\"\u003e\n\u003cp\u003eCSA Certified Process Control Equipment. See CSA File LR54689C.\u003c\/p\u003e\n\u003cp\u003eCSA Certified Process Control Equipment for Class I, Division 2 Group A,B,C,D Hazardous Locations. See CSA File LR69960C.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 19.1361%;\"\u003e\u003cstrong\u003eCE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80.5401%;\"\u003e\n\u003cp\u003eEuropean Union 2014\/30\/EU EMC Directive, compliant with:\u003c\/p\u003e\n\u003cp\u003e* EN 61326-1; Meas.\/Control\/Lab., Industrial Requirements\u003c\/p\u003e\n\u003cp\u003e* EN 61000-6-2; Industrial Immunity\u003c\/p\u003e\n\u003cp\u003e* EN 61000-6-4; Industrial Emissions\u003c\/p\u003e\n\u003cp\u003e* EN 61131-2; Programmable Controllers (Clause 8, Zone A \u0026amp; B)\u003c\/p\u003e\n\u003cp\u003eEuropean Union 2014\/35\/EU LVD, compliant with:\u003c\/p\u003e\n\u003cp\u003e* EN 61131-2; Programmable Controllers (Clause 11)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 19.1361%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80.5401%;\"\u003e\n\u003cp\u003eAustralian Radiocommunications Act, compliant with:\u003c\/p\u003e\n\u003cp\u003e* EN 61000-6-4; Industrial Emissions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 19.1361%;\"\u003e\u003cstrong\u003eFM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80.5401%;\"\u003eFM Approved Equipment for use in Class I Division 2 Group A,B,C,D Hazardous Locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 19.1361%;\"\u003e\u003cstrong\u003eKC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80.5401%;\"\u003e\n\u003cp\u003eKorean Registration of Broadcasting and Communications Equipment, compliant with:\u003c\/p\u003e\n\u003cp\u003e* Article 58-2 of Radio Waves Act, Clause 3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 19.1361%;\"\u003e\u003cstrong\u003eEAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80.5401%;\"\u003e\n\u003cp\u003eRussian Customs Union TR CU 020\/2011 EMC Technical Regulation\u003c\/p\u003e\n\u003cp\u003eRussian Customs Union TR CU 004\/2011 LV Technical Regulation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Mounting:\u003c\/strong\u003e Securely seat the module into any available slot of a ControlLogix chassis until the top and bottom latches catch firmly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring \u0026amp; Connection:\u003c\/strong\u003e Connect field wiring to a compatible 36-pin Removable Terminal Block (RTB) housing (such as 1756-TBCH or 1756-TBS6H) before attaching the RTB to the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Grounding:\u003c\/strong\u003e Ensure proper chassis grounding according to standard industrial automation wiring and grounding guidelines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeying:\u003c\/strong\u003e Utilize user-defined mechanical RTB keying and software-configurable electronic keying to prevent incorrect module placement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed Industrial Control Equipment\u003c\/li\u003e\n\u003cli\u003eCSA Certified Process Control Equipment\u003c\/li\u003e\n\u003cli\u003eCE Compliant (EMC \u0026amp; LVD Directives)\u003c\/li\u003e\n\u003cli\u003eRCM (Australian Radiocommunications Act)\u003c\/li\u003e\n\u003cli\u003eFM Approved for Class I, Division 2 Hazardous Locations\u003c\/li\u003e\n\u003cli\u003eKC (Korean Registration of Broadcasting and Communications Equipment)\u003c\/li\u003e\n\u003cli\u003eEAC (Russian Customs Union TR CU)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695178215787,"sku":"1756-OA16I","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-oa16i-ac-digital-output-module-afek2zj2pts_a61528b8-e82b-402d-ba27-f0c7d4ccaf61.jpg?v=1766114198","url":"https:\/\/www.plcprotech.com\/products\/allen-bradley-1756-oa16i-controllogix-16-point-ac-isolated-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}