{"product_id":"allen-bradley-1756-pa75-controllogix-ac-power-supply","title":"Allen-Bradley 1756-PA75 ControlLogix AC Power Supply","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1756-PA75\u003c\/strong\u003e is a standard \u003cstrong\u003eControlLogix\u003c\/strong\u003e AC power supply designed to mount directly onto the left side of a \u003cstrong\u003e1756 ControlLogix\u003c\/strong\u003e chassis. It converts standard alternating current input into regulated DC power to supply the backplane, supporting system controllers, I\/O modules, and communication modules. The \u003cstrong\u003e1756-PA75\u003c\/strong\u003e delivers up to 75 W of total output power at surrounding operating temperatures up to 60 degC.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMounts on the left side of compatible 1756 ControlLogix chassis.\u003c\/li\u003e\n\u003cli\u003eWide input voltage capability supporting nominal 120V\/240V AC ranges.\u003c\/li\u003e\n\u003cli\u003eMulti-voltage DC backplane power distribution providing 1.2V DC, 3.3V DC, 5.1V DC, and 24V DC outputs.\u003c\/li\u003e\n\u003cli\u003eReinforced insulation isolation between power input and the chassis backplane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial Control Systems using ControlLogix PAC platforms.\u003c\/li\u003e\n\u003cli\u003eFactory automation backplane power distribution.\u003c\/li\u003e\n\u003cli\u003eProcess control cabinet installations requiring high-reliability AC power inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-PA75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85...265V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage, Nominal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120V\/240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Frequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47...63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Power, Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100VA \/ 100 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Power, Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 W @ 0...60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current, Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Capacity @ 1.2V DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Capacity @ 3.3V DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Capacity @ 5.1V DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Capacity @ 24V DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250V (continuous), Reinforced Insulation Type, Power Input to Backplane (Type tested at 3500V DC for 60 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLeft side of 1756 chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17 (Series B, Series C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 mm2 (14 AWG) solid or stranded copper wire rated at 90 degC or greater, 1.2 mm insulation max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-on power ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Screw Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.565 N-m (5 lb-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Type Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (open-style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNonoperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 g @ 10...500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNonoperating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (Approx.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.0 x 11.2 x 14.5 cm (5.51 x 4.41 x 5.71 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (Approx.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.95 kg (2.10 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Position:\u003c\/strong\u003e Install directly on the far-left slot position of the 1756 ControlLogix chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Requirements:\u003c\/strong\u003e Use 2.5 mm2 (14 AWG) solid or stranded copper wire rated at 90 degC or higher, with maximum insulation thickness of 1.2 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque Specifications:\u003c\/strong\u003e Tighten field-wiring conductor screws to 0.565 N-m (5 lb-in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Considerations:\u003c\/strong\u003e Ensure adequate cabinet ventilation so surrounding air temperature does not exceed 60 degC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e UL Listed Industrial Control Equipment (File E65584)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ec-UL-us:\u003c\/strong\u003e UL Listed Industrial Control Equipment for US and Canada (File E65584); Class I, Division 2 Group A, B, C, D Hazardous Locations (File E194810)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e CSA Certified Process Control Equipment (File LR54689C); Class I, Division 2 Group A, B, C, D (File LR69960C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFM:\u003c\/strong\u003e FM Approved Equipment for Class I Division 2 Group A, B, C, D Hazardous Locations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Union 2014\/30\/EU EMC Directive (EN 61326-1, EN 61000-6-2, EN 61000-6-4, EN 61131-2) and 2014\/35\/EU LVD Directive (EN 61010-2-201, EN 61131-2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e Compliance with Electromagnetic Compatibility, Electrical Equipment Safety, and Explosive Atmospheres Regulations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCM:\u003c\/strong\u003e Australian Radiocommunications Act compliant (EN 61000-6-4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC:\u003c\/strong\u003e Korean Registration of Broadcasting and Communications Equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAC:\u003c\/strong\u003e Russian Customs Union TR CU 020\/2011 EMC and TR CU 004\/2011 LV Technical Regulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e CNCA-C23-01 Implementation Rule Explosion-Proof Electrical Products\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695177232747,"sku":"1756-PA75","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-pa75-controllogix-ac-power-supply-gmm1lbqhwmx_e2429603-94a7-4bb6-b70b-48d4ebf57be3.jpg?v=1766114153","url":"https:\/\/www.plcprotech.com\/products\/allen-bradley-1756-pa75-controllogix-ac-power-supply","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}