{"product_id":"allen-bradley-1756-pb75r-controllogix-dc-redundant-power-supply","title":"Allen-Bradley 1756-PB75R ControlLogix DC Redundant Power Supply","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e1756-PB75R\u003c\/strong\u003e is a \u003cstrong\u003eControlLogix DC redundant power supply\u003c\/strong\u003e for redundant chassis power configurations. Two power supplies operate together through a redundant power supply chassis adapter.\u003c\/p\u003e\n\u003cp\u003eThe paired supplies automatically share the chassis load during normal operation. This arrangement maintains backplane power when one supply experiences an operational anomaly.\u003c\/p\u003e\n\u003cp\u003eThe module accepts a nominal 24V DC input. It provides regulated 1.2V DC, 3.3V DC, 5.1V DC, and 24V DC outputs to the ControlLogix backplane.\u003c\/p\u003e\n\u003cp\u003eVisual status indicators show the operating condition of the supply pair. A solid-state annunciator relay supports external status monitoring through an input module.\u003c\/p\u003e\n\u003cp\u003eThe redundant system requires two power supplies, two redundant power cables, and one chassis adapter. The redundancy design covers power supply anomalies but excludes the chassis adapter and power cables.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRedundant operation with two matched power supplies\u003c\/li\u003e\n\u003cli\u003eAutomatic chassis load sharing\u003c\/li\u003e\n\u003cli\u003eVisual status indication for the supply pair\u003c\/li\u003e\n\u003cli\u003eSolid-state relay for external supply-status monitoring\u003c\/li\u003e\n\u003cli\u003eSeparate annunciator connection for system diagnostics\u003c\/li\u003e\n\u003cli\u003eCompatible with ControlLogix redundant power supply chassis adapters\u003c\/li\u003e\n\u003cli\u003eSupports one-chassis and two-chassis redundant configurations\u003c\/li\u003e\n\u003cli\u003eOpen-style construction for enclosure installation\u003c\/li\u003e\n\u003cli\u003eRedundancy coverage limited to power supply operational anomalies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRedundant ControlLogix chassis power\u003c\/li\u003e\n\u003cli\u003eContinuous process control systems\u003c\/li\u003e\n\u003cli\u003eProduction line control systems\u003c\/li\u003e\n\u003cli\u003eMachine control requiring power supply redundancy\u003c\/li\u003e\n\u003cli\u003eCritical controller and I\/O chassis\u003c\/li\u003e\n\u003cli\u003eProcess monitoring and supervisory control\u003c\/li\u003e\n\u003cli\u003eIndustrial systems requiring power status annunciation\u003c\/li\u003e\n\u003cli\u003eControl cabinets requiring automatic load sharing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eInformation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e1756-PB75R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnique Product Identifier\u003c\/td\u003e\n\u003ctd\u003e1756-PB75R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e612598274246\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Description\u003c\/td\u003e\n\u003ctd\u003eControlLogix DC Redundant Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEstimated Lead Time\u003c\/td\u003e\n\u003ctd\u003e5 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eMexico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eRedundant System Components\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eRequired Quantity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1756-PB75R\/A\u003c\/td\u003e\n\u003ctd\u003eRedundant DC power supply\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1756-CPR2, 1756-CPR2D, or 1756-CPR2U\u003c\/td\u003e\n\u003ctd\u003eRedundant power supply cable, 0.91 m (3 ft)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1756-PSCA2, 1756-PSCA2K, or 1756-PSCA2XT\u003c\/td\u003e\n\u003ctd\u003eRedundant power supply chassis adapter\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser-supplied wiring\u003c\/td\u003e\n\u003ctd\u003eOptional annunciator wiring, 10 m (32.8 ft) maximum\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e1756-PB75R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eControlLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDC Redundant Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Type\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant Operation\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Load Sharing\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type Rating\u003c\/td\u003e\n\u003ctd\u003eNone, open-style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eMexico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable for Safety Functions\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eInput and Output Ratings\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18...32V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Power\u003c\/td\u003e\n\u003ctd\u003e110 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inrush Current\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Power\u003c\/td\u003e\n\u003ctd\u003e75 W at 0...60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-Up Time\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current at 1.2V DC\u003c\/td\u003e\n\u003ctd\u003e1.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current at 3.3V DC\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current at 5.1V DC\u003c\/td\u003e\n\u003ctd\u003e13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current at 24V DC\u003c\/td\u003e\n\u003ctd\u003e2.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnnunciator Power\u003c\/td\u003e\n\u003ctd\u003e90V DC for ATEX\/IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnnunciator Pilot Duty\u003c\/td\u003e\n\u003ctd\u003eNot rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eElectrical Isolation\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e250V continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Type\u003c\/td\u003e\n\u003ctd\u003eReinforced insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Paths\u003c\/td\u003e\n\u003ctd\u003ePower input to backplane, power input to annunciator, and annunciator to backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Type Test\u003c\/td\u003e\n\u003ctd\u003e3250V DC for 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eMechanical Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e17.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e14.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e13.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Weight\u003c\/td\u003e\n\u003ctd\u003e1.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTop Mounting Hole Diameter\u003c\/td\u003e\n\u003ctd\u003e1.1 cm and 0.55 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBottom Mounting Hole Diameter\u003c\/td\u003e\n\u003ctd\u003e0.55 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Screw Torque\u003c\/td\u003e\n\u003ctd\u003e0.565 N.m (5 lb.in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eChassis Compatibility\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Chassis\u003c\/td\u003e\n\u003ctd\u003e1756-A4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Chassis\u003c\/td\u003e\n\u003ctd\u003e1756-A7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Chassis\u003c\/td\u003e\n\u003ctd\u003e1756-A10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Chassis\u003c\/td\u003e\n\u003ctd\u003e1756-A13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Chassis\u003c\/td\u003e\n\u003ctd\u003e1756-A17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eWiring Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Conductor\u003c\/td\u003e\n\u003ctd\u003e2.5 mm2 (14 AWG) solid or stranded copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Conductor Temperature Rating\u003c\/td\u003e\n\u003ctd\u003e90 degC or greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Conductor Insulation\u003c\/td\u003e\n\u003ctd\u003e1.2 mm (3\/64 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnnunciator Conductor\u003c\/td\u003e\n\u003ctd\u003e0.25...2.5 mm2 (22...14 AWG) solid or stranded copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnnunciator Conductor Temperature Rating\u003c\/td\u003e\n\u003ctd\u003e90 degC or greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Annunciator Conductor Insulation\u003c\/td\u003e\n\u003ctd\u003e1.2 mm (3\/64 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Port Wire Category\u003c\/td\u003e\n\u003ctd\u003eCategory 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnnunciator Port Wire Category\u003c\/td\u003e\n\u003ctd\u003eCategory 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1756-CPR2 Connection Wire Category\u003c\/td\u003e\n\u003ctd\u003eCategory 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0...60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Surrounding Air Temperature\u003c\/td\u003e\n\u003ctd\u003e60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonoperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40...+85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5...95%, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Vibration\u003c\/td\u003e\n\u003ctd\u003e2 g at 10...500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Shock\u003c\/td\u003e\n\u003ctd\u003e30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonoperating Shock\u003c\/td\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNorth American Temperature Code\u003c\/td\u003e\n\u003ctd\u003eT4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX Temperature Code\u003c\/td\u003e\n\u003ctd\u003eT4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIEC Temperature Code\u003c\/td\u003e\n\u003ctd\u003eT4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eElectromagnetic Compatibility\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissions\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESD Immunity\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-4-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESD Contact Discharge\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESD Air Discharge\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiated RF Immunity\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-4-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiated RF, 80...2000 MHz\u003c\/td\u003e\n\u003ctd\u003e10 V\/m with 1 kHz sine wave, 80% AM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiated RF at 900 MHz\u003c\/td\u003e\n\u003ctd\u003e10 V\/m with 200 Hz, 50% pulse, 100% AM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiated RF at 1890 MHz\u003c\/td\u003e\n\u003ctd\u003e10 V\/m with 200 Hz, 50% pulse, 100% AM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiated RF, 2000...2700 MHz\u003c\/td\u003e\n\u003ctd\u003e3 V\/m with 1 kHz sine wave, 80% AM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEFT\/B Immunity\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-4-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEFT\/B on Power Ports\u003c\/td\u003e\n\u003ctd\u003e+\/-4 kV at 5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEFT\/B on Annunciator Ports\u003c\/td\u003e\n\u003ctd\u003e+\/-4 kV at 5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Transient Immunity\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-4-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge on Power Ports\u003c\/td\u003e\n\u003ctd\u003e+\/-1 kV line-line and +\/-2 kV line-earth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConducted RF Immunity\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-4-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConducted RF Level\u003c\/td\u003e\n\u003ctd\u003e15 V rms from 150 kHz...80 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eDC Supply Voltage Variation\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-4-29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Interruption\u003c\/td\u003e\n\u003ctd\u003e10 ms on DC supply ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Dip\u003c\/td\u003e\n\u003ctd\u003e60% for 100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Dip\u003c\/td\u003e\n\u003ctd\u003e100% for 50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Fluctuation\u003c\/td\u003e\n\u003ctd\u003e+\/-20% for 15 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong Interruption\u003c\/td\u003e\n\u003ctd\u003e5 s on DC supply ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eSustainability\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLCA Method\u003c\/td\u003e\n\u003ctd\u003eISO 14040\/44 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpact Assessment Method\u003c\/td\u003e\n\u003ctd\u003eEF 3.0 Environmental Footprint, ESPR aligned\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDatabase\u003c\/td\u003e\n\u003ctd\u003eEcoinvent 3.10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUse-Phase Electricity\u003c\/td\u003e\n\u003ctd\u003eEuropean Average Grid Mix, EU-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCradle-to-Grave Impact\u003c\/td\u003e\n\u003ctd\u003e1.58E+03 kg CO2 eq\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCradle-to-Gate Impact\u003c\/td\u003e\n\u003ctd\u003e6.17E+01 kg CO2 eq\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecycled Product Material\u003c\/td\u003e\n\u003ctd\u003e3.98%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndependent Review\u003c\/td\u003e\n\u003ctd\u003eThird-party reviewed under ISO 14071 and the EU Product Environmental Footprint framework\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input Ports\u003c\/td\u003e\n\u003ctd\u003eAccept the 18...32V DC supply input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnnunciator Ports\u003c\/td\u003e\n\u003ctd\u003eConnect the solid-state status relay to an input module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1756-CPR2 Connection\u003c\/td\u003e\n\u003ctd\u003eConnects the redundant power supply to the chassis adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1756-PSCA2 Interface\u003c\/td\u003e\n\u003ctd\u003eFunnels power from two redundant supplies to the chassis backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Output\u003c\/td\u003e\n\u003ctd\u003eSupplies regulated 1.2V DC, 3.3V DC, 5.1V DC, and 24V DC rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe standard \u003cstrong\u003e1756-CPR2\u003c\/strong\u003e cable has a 0.91 m length and a 12.7 cm bend radius. The 1756-CPR2D and 1756-CPR2U require 10.16 cm clearance beside the chassis adapter.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall two redundant power supplies for each redundant supply pair.\u003c\/li\u003e\n\u003cli\u003eConnect each power supply to the chassis adapter with a separate redundant power cable.\u003c\/li\u003e\n\u003cli\u003eInstall one compatible chassis adapter for each redundant chassis power connection.\u003c\/li\u003e\n\u003cli\u003eUse the 1756-PSCA2, 1756-PSCA2K, or 1756-PSCA2XT chassis adapter.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified bend radius or clearance for the selected power cables.\u003c\/li\u003e\n\u003cli\u003eUse Category 1 routing for power conductors.\u003c\/li\u003e\n\u003cli\u003eUse Category 3 routing for annunciator and 1756-CPR2 connections.\u003c\/li\u003e\n\u003cli\u003eUse copper conductors rated for at least 90 degC.\u003c\/li\u003e\n\u003cli\u003eTighten conductor screws to 0.565 N.m.\u003c\/li\u003e\n\u003cli\u003eInstall the open-style supply inside a suitable industrial enclosure.\u003c\/li\u003e\n\u003cli\u003eConnect optional annunciator wiring to an input module for remote status monitoring.\u003c\/li\u003e\n\u003cli\u003eLimit annunciator wiring length to 10 m.\u003c\/li\u003e\n\u003cli\u003eConfirm both supply status indicators before placing the system into service.\u003c\/li\u003e\n\u003cli\u003eDo not treat the chassis adapter or power cables as redundant fault-covered components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ec-UL-us\u003c\/td\u003e\n\u003ctd\u003eUL Listed Industrial Control Equipment for the United States and Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location Listing\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 2, Groups A, B, C, and D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSA\u003c\/td\u003e\n\u003ctd\u003eCSA Certified Process Control Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFM\u003c\/td\u003e\n\u003ctd\u003eFM Approved for Class I, Division 2, Groups A, B, C, and D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUKCA\u003c\/td\u003e\n\u003ctd\u003eConforms to applicable UK EMC, electrical safety, explosive atmosphere, and restricted substance regulations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003ctd\u003eEU EMC and Low Voltage Directive compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRCM\u003c\/td\u003e\n\u003ctd\u003eAustralian Radiocommunications Act compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX\u003c\/td\u003e\n\u003ctd\u003eII 3 G Ex ec IIC T4 Gc, UL 22 ATEX 2819X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIECEx\u003c\/td\u003e\n\u003ctd\u003eII 3 G Ex ec IIC T4 Gc, IECEx UL 22.0064X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUKEX\u003c\/td\u003e\n\u003ctd\u003eIncreased safety \"e\", UL22UKEX2605X, Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKC\u003c\/td\u003e\n\u003ctd\u003eKorean broadcasting and communications equipment registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAC\u003c\/td\u003e\n\u003ctd\u003eTR CU 020\/2011 and TR CU 004\/2011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCC\u003c\/td\u003e\n\u003ctd\u003eCCC 2020122309111830, 2020122309111998, and 2020122309113868\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695182705003,"sku":"1756-PB75R","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-pb75r-dc-redundant-power-supply-eybi0pw1y1a_08de55c4-b822-4633-8bef-fa7a482bdf01.jpg?v=1766114351","url":"https:\/\/www.plcprotech.com\/products\/allen-bradley-1756-pb75r-controllogix-dc-redundant-power-supply","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}