{"product_id":"allen-bradley-1761-l32awa-micrologix-1000-32-point-programmable-controller","title":"Allen-Bradley 1761-L32AWA MicroLogix 1000 32-Point Programmable Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e1761-L32AWA\u003c\/strong\u003e is a fixed-I\/O \u003cstrong\u003eMicroLogix 1000 programmable controller\u003c\/strong\u003e for standalone machine and process control. It integrates an AC power supply, processor, memory, discrete I\/O, and serial communication functions.\u003c\/p\u003e\n\u003cp\u003eThe controller provides 20 digital inputs for 120V AC field signals and 12 relay outputs. The relay contacts can switch supported AC or DC loads used by contactors, motor starters, solenoids, indicators, and other control devices.\u003c\/p\u003e\n\u003cp\u003eA built-in \u003cstrong\u003eRS-232 interface\u003c\/strong\u003e supports \u003cstrong\u003eDF1 communication\u003c\/strong\u003e for programming, monitoring, and controller communication. The control program is retained in nonvolatile EEPROM memory.\u003c\/p\u003e\n\u003cp\u003eThe compact controller supports DIN rail or screw mounting inside an industrial enclosure. Horizontal mounting provides the full specified operating temperature range.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFixed controller architecture with integrated processor, power supply, and discrete I\/O\u003c\/li\u003e\n\u003cli\u003eNonvolatile EEPROM program storage\u003c\/li\u003e\n\u003cli\u003eRelay outputs for supported AC and DC loads\u003c\/li\u003e\n\u003cli\u003eDF1 serial communication through the RS-232 interface\u003c\/li\u003e\n\u003cli\u003eDIN rail or mounting-screw installation\u003c\/li\u003e\n\u003cli\u003eHorizontal or vertical enclosure mounting\u003c\/li\u003e\n\u003cli\u003eFunctional earth connection for noise immunity\u003c\/li\u003e\n\u003cli\u003eReplaceable wiring without separate plug-in I\/O modules\u003c\/li\u003e\n\u003cli\u003eSurge suppression support for inductive output loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandalone machine control\u003c\/li\u003e\n\u003cli\u003eConveyor sequencing\u003c\/li\u003e\n\u003cli\u003eMotor starter control\u003c\/li\u003e\n\u003cli\u003eSolenoid valve control\u003c\/li\u003e\n\u003cli\u003ePump and fan control\u003c\/li\u003e\n\u003cli\u003ePackaging equipment\u003c\/li\u003e\n\u003cli\u003eMaterial handling systems\u003c\/li\u003e\n\u003cli\u003eRelay-based equipment interlocking\u003c\/li\u003e\n\u003cli\u003eSmall production machinery\u003c\/li\u003e\n\u003cli\u003eEquipment status monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eInformation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e1761-L32AWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnique Product Identifier\u003c\/td\u003e\n\u003ctd\u003e1761-L32AWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e662468368704\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Description\u003c\/td\u003e\n\u003ctd\u003eMicroLogix 1000, 120\/240V AC power, 20 120V AC digital inputs, and 12 relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Class\u003c\/td\u003e\n\u003ctd\u003eController\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e1761-L32AWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eMicroLogix 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFixed-I\/O Programmable Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Digital I\/O\u003c\/td\u003e\n\u003ctd\u003e32 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e120V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eRelay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eDF1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e1K EEPROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram and Data Capacity\u003c\/td\u003e\n\u003ctd\u003eApproximately 737 instruction words and 437 data words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003ePower Requirements\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Power Supply\u003c\/td\u003e\n\u003ctd\u003e120\/240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85...264V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47...63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Usage at 120V AC\u003c\/td\u003e\n\u003ctd\u003e19 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Usage at 240V AC\u003c\/td\u003e\n\u003ctd\u003e25 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inrush Current\u003c\/td\u003e\n\u003ctd\u003e30 A for 8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Power Cycles\u003c\/td\u003e\n\u003ctd\u003e50,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eDigital Input Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Controller Class\u003c\/td\u003e\n\u003ctd\u003e100...120V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e79...132V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency Range\u003c\/td\u003e\n\u003ctd\u003e47...63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum On-State Voltage\u003c\/td\u003e\n\u003ctd\u003e79V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum On-State Voltage\u003c\/td\u003e\n\u003ctd\u003e132V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n\u003ctd\u003e20V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum On-State Current\u003c\/td\u003e\n\u003ctd\u003e5.0 mA at 79V AC, 47 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal On-State Current\u003c\/td\u003e\n\u003ctd\u003e12.0 mA at 120V AC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum On-State Current\u003c\/td\u003e\n\u003ctd\u003e16.0 mA at 132V AC, 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Off-State Current\u003c\/td\u003e\n\u003ctd\u003e2.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Impedance at 50 Hz\u003c\/td\u003e\n\u003ctd\u003e12K ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Impedance at 60 Hz\u003c\/td\u003e\n\u003ctd\u003e10K ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Inrush\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eRelay Output Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eRelay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Current\u003c\/td\u003e\n\u003ctd\u003e10.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load per Controller\u003c\/td\u003e\n\u003ctd\u003e1440 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per Common\u003c\/td\u003e\n\u003ctd\u003e8.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Off-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-to-On Response\u003c\/td\u003e\n\u003ctd\u003e10 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-to-Off Response\u003c\/td\u003e\n\u003ctd\u003e10 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Relay Life\u003c\/td\u003e\n\u003ctd\u003e20,000,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eRelay Contact Ratings\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Voltage\u003c\/th\u003e\n\u003cth\u003eMake Current\u003c\/th\u003e\n\u003cth\u003eBreak Current\u003c\/th\u003e\n\u003cth\u003eContinuous Current\u003c\/th\u003e\n\u003cth\u003eMake Rating\u003c\/th\u003e\n\u003cth\u003eBreak Rating\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e240V AC\u003c\/td\u003e\n\u003ctd\u003e7.5 A\u003c\/td\u003e\n\u003ctd\u003e0.75 A\u003c\/td\u003e\n\u003ctd\u003e2.5 A\u003c\/td\u003e\n\u003ctd\u003e1800 VA\u003c\/td\u003e\n\u003ctd\u003e180 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120V AC\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003ctd\u003e1.5 A\u003c\/td\u003e\n\u003ctd\u003e2.5 A\u003c\/td\u003e\n\u003ctd\u003e1800 VA\u003c\/td\u003e\n\u003ctd\u003e180 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e125V DC\u003c\/td\u003e\n\u003ctd\u003e0.22 A\u003c\/td\u003e\n\u003ctd\u003e0.22 A\u003c\/td\u003e\n\u003ctd\u003e1.0 A\u003c\/td\u003e\n\u003ctd\u003e28 VA\u003c\/td\u003e\n\u003ctd\u003e28 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003ctd\u003e1.2 A\u003c\/td\u003e\n\u003ctd\u003e1.2 A\u003c\/td\u003e\n\u003ctd\u003e2.0 A\u003c\/td\u003e\n\u003ctd\u003e28 VA\u003c\/td\u003e\n\u003ctd\u003e28 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eDo not exceed the specified current per common. For DC applications, relay make and break ratings depend on the applied voltage.\u003c\/p\u003e\n\u003ch4\u003eMechanical Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e200 mm (7.87 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e80 mm (3.15 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e73 mm (2.87 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Methods\u003c\/td\u003e\n\u003ctd\u003eDIN rail or mounting screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Minimum Clearance\u003c\/td\u003e\n\u003ctd\u003e50.8 mm (2 in.) at the top, bottom, and sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Terminal Screw Torque\u003c\/td\u003e\n\u003ctd\u003e0.9 N.m (8.0 in.lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eWiring Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolid Wire Size\u003c\/td\u003e\n\u003ctd\u003e14...22 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStranded Wire Size\u003c\/td\u003e\n\u003ctd\u003e16...22 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Conductors per Terminal Screw\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Spade Lug for 22...16 AWG\u003c\/td\u003e\n\u003ctd\u003eAMP 53120-1 or equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Spade Lug for 16...14 AWG\u003c\/td\u003e\n\u003ctd\u003eAMP 53123-1 or equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Screw Head Diameter\u003c\/td\u003e\n\u003ctd\u003e5.5 mm (0.220 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature, Horizontal Mounting\u003c\/td\u003e\n\u003ctd\u003e0...55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature, Vertical Mounting\u003c\/td\u003e\n\u003ctd\u003e0...40 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40...85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5...95%, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Vibration, Panel Mounted\u003c\/td\u003e\n\u003ctd\u003e5 Hz...2 kHz, 0.381 mm peak-to-peak, 2.5g, 1 hour per axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonoperating Vibration\u003c\/td\u003e\n\u003ctd\u003e5 Hz...2 kHz, 0.762 mm peak-to-peak, 5g, 1 hour per axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Shock\u003c\/td\u003e\n\u003ctd\u003e10g peak acceleration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Shock, DIN Rail Mounted\u003c\/td\u003e\n\u003ctd\u003e7.5g peak acceleration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonoperating Shock\u003c\/td\u003e\n\u003ctd\u003e20g peak acceleration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrostatic Discharge\u003c\/td\u003e\n\u003ctd\u003eEN 61000-2 at 8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFast Transient\u003c\/td\u003e\n\u003ctd\u003eEN 61000-4 at 2 kV on power supply and I\/O; 1 kV on communication circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eRelay-equipped 32-point controllers require an additional 2.5g derating for the specified shock rating.\u003c\/p\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Power Input\u003c\/td\u003e\n\u003ctd\u003eSupplies operating power from a 120\/240V AC source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs I\/0...I\/19\u003c\/td\u003e\n\u003ctd\u003eAccept 20 discrete 120V AC input signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs O\/0...O\/11\u003c\/td\u003e\n\u003ctd\u003eSwitch 12 supported AC or DC output loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Common Terminals\u003c\/td\u003e\n\u003ctd\u003eProvide common connections for relay output groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS-232 Port\u003c\/td\u003e\n\u003ctd\u003eSupports DF1 programming and controller communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Earth Terminal\u003c\/td\u003e\n\u003ctd\u003eProvides a low-impedance earth path for noise immunity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the controller inside an enclosure.\u003c\/li\u003e\n\u003cli\u003eMount the controller horizontally when the full operating temperature range is required.\u003c\/li\u003e\n\u003cli\u003eUse either a DIN rail or mounting screws for horizontal installation.\u003c\/li\u003e\n\u003cli\u003eUse mounting screws for greater stability when mounting vertically.\u003c\/li\u003e\n\u003cli\u003ePosition the nameplate downward for vertical mounting.\u003c\/li\u003e\n\u003cli\u003eMaintain at least 50.8 mm of clearance at the top, bottom, and sides.\u003c\/li\u003e\n\u003cli\u003eKeep the protective wrap installed while drilling and wiring.\u003c\/li\u003e\n\u003cli\u003ePrevent metal chips and wire fragments from entering the controller.\u003c\/li\u003e\n\u003cli\u003eRemove the protective wrap after wiring to prevent overheating.\u003c\/li\u003e\n\u003cli\u003eConnect the functional earth terminal directly to the ground bus.\u003c\/li\u003e\n\u003cli\u003eUse the heaviest permitted conductor for the ground connection.\u003c\/li\u003e\n\u003cli\u003eTighten terminal screws to no more than 0.9 N.m.\u003c\/li\u003e\n\u003cli\u003eInstall surge suppression directly across inductive loads.\u003c\/li\u003e\n\u003cli\u003ePosition suppression devices as close as possible to the controlled load.\u003c\/li\u003e\n\u003cli\u003eDo not connect or disconnect equipment while energized in a hazardous location.\u003c\/li\u003e\n\u003cli\u003eUse only approved communication cables in Class I, Division 2 installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eC-UL\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 2, Groups A, B, C, and D, when marked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\u003c\/td\u003e\n\u003ctd\u003eUL Listed for Class I, Division 2, Groups A, B, C, and D, when marked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003ctd\u003eCompliant with applicable directives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRCM\u003c\/td\u003e\n\u003ctd\u003eCompliant with applicable directives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAC\u003c\/td\u003e\n\u003ctd\u003eCompliant with applicable directives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location Suitability\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 2, Groups A, B, C, and D, or nonhazardous locations when marked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695180280171,"sku":"1761-L32AWA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1761-l32awa-micrologix-1000-controller-unit-e1jpiuuvanz_75ec0d24-6a5e-457a-9e1b-10c2ffa523ed.jpg?v=1766114259","url":"https:\/\/www.plcprotech.com\/products\/allen-bradley-1761-l32awa-micrologix-1000-32-point-programmable-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}