{"product_id":"allen-bradley-1771-ife-plc-5-analog-input-module","title":"Allen-Bradley 1771-IFE PLC-5 Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1771-IFE\u003c\/strong\u003e is an intelligent block transfer analog input module designed to interface analog input signals with Allen-Bradley programmable controllers that feature block transfer capability within the 1771 I\/O structure. The \u003cstrong\u003e1771-IFE\u003c\/strong\u003e senses up to 16 single-ended or 8 differential analog inputs, converting input signals into proportional four-digit BCD or 12-bit binary values for transfer to the controller data table.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports up to 16 single-ended or 8 differential analog inputs per module.\u003c\/li\u003e\n\u003cli\u003ePer-channel program selectable input ranges for voltage and current.\u003c\/li\u003e\n\u003cli\u003eSelectable data format including BCD, two's complement binary, and signed magnitude binary.\u003c\/li\u003e\n\u003cli\u003eProgrammable digital filtering to reduce process noise effects on input signals.\u003c\/li\u003e\n\u003cli\u003eSelectable Real Time Sampling (RTS) for time-based control functions.\u003c\/li\u003e\n\u003cli\u003eSoftware scaling to engineering units on an individual channel basis.\u003c\/li\u003e\n\u003cli\u003eInternal configuration jumpers for selecting voltage or current mode.\u003c\/li\u003e\n\u003cli\u003eFront panel green RUN and red FAULT status indicator lights.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProcess control systems utilizing PLC-2, PLC-3, or PLC-5 processors.\u003c\/li\u003e\n\u003cli\u003eIndustrial monitoring of voltage and current loop transmitters.\u003c\/li\u003e\n\u003cli\u003eTime-based process calculations such as PID control loops and totalization.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1771-IFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500mA at 5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 single-ended or 8 differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Ranges (Voltage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 5V DC, 0 to 5V DC, -5 to +5V DC, -10 to +10V DC, 0 to 10V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Ranges (Current)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 20mA, 0 to 20mA, -20 to +20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit binary or 4-digit BCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Formats\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBCD, Two's complement binary, Signed magnitude binary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Common Mode Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+14.25V DC referenced to module common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Filter Time Constant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 0.99 seconds (BCD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReal Time Sampling Period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100ms to 3.1s (in 100ms increments)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Arm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCat. No. 1771-WG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScan Time (8 Differential)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.7ms (no scaling or digital filter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScan Time (16 Single-ended)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.4ms (no scaling or digital filter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRUN (Green), FAULT (Red)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003ch4\u003eSingle-Ended Input Wiring Assignments (1771-WG)\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 1\u003c\/td\u003e\n\u003ctd\u003eChannel 1 Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 2\u003c\/td\u003e\n\u003ctd\u003eChannel 2 Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 3\u003c\/td\u003e\n\u003ctd\u003eChannel 3 Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 4\u003c\/td\u003e\n\u003ctd\u003eChannel 4 Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 5\u003c\/td\u003e\n\u003ctd\u003eModule Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 6\u003c\/td\u003e\n\u003ctd\u003eChannel 5 Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 7\u003c\/td\u003e\n\u003ctd\u003eChannel 6 Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 8\u003c\/td\u003e\n\u003ctd\u003eChannel 7 Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 9\u003c\/td\u003e\n\u003ctd\u003eChannel 8 Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 10\u003c\/td\u003e\n\u003ctd\u003eModule Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 11\u003c\/td\u003e\n\u003ctd\u003eChannel 9 Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 12\u003c\/td\u003e\n\u003ctd\u003eChannel 10 Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 13\u003c\/td\u003e\n\u003ctd\u003eChannel 11 Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 14\u003c\/td\u003e\n\u003ctd\u003eChannel 12 Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 15\u003c\/td\u003e\n\u003ctd\u003eModule Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 16\u003c\/td\u003e\n\u003ctd\u003eChannel 13 Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 17\u003c\/td\u003e\n\u003ctd\u003eChannel 14 Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 18\u003c\/td\u003e\n\u003ctd\u003eChannel 15 Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 19\u003c\/td\u003e\n\u003ctd\u003eChannel 16 Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 20\u003c\/td\u003e\n\u003ctd\u003eModule Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 21\u003c\/td\u003e\n\u003ctd\u003eModule Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eDifferential Input Wiring Assignments (1771-WG)\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 1\u003c\/td\u003e\n\u003ctd\u003eChannel 1+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 2\u003c\/td\u003e\n\u003ctd\u003eChannel 1-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 3\u003c\/td\u003e\n\u003ctd\u003eChannel 2+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 4\u003c\/td\u003e\n\u003ctd\u003eChannel 2-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 5\u003c\/td\u003e\n\u003ctd\u003eNot used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 6\u003c\/td\u003e\n\u003ctd\u003eChannel 3+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 7\u003c\/td\u003e\n\u003ctd\u003eChannel 3-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 8\u003c\/td\u003e\n\u003ctd\u003eChannel 4+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 9\u003c\/td\u003e\n\u003ctd\u003eChannel 4-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 10\u003c\/td\u003e\n\u003ctd\u003eNot used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 11\u003c\/td\u003e\n\u003ctd\u003eChannel 5+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 12\u003c\/td\u003e\n\u003ctd\u003eChannel 5-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 13\u003c\/td\u003e\n\u003ctd\u003eChannel 6+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 14\u003c\/td\u003e\n\u003ctd\u003eChannel 6-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 15\u003c\/td\u003e\n\u003ctd\u003eNot used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 16\u003c\/td\u003e\n\u003ctd\u003eChannel 7+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 17\u003c\/td\u003e\n\u003ctd\u003eChannel 7-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 18\u003c\/td\u003e\n\u003ctd\u003eChannel 8+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 19\u003c\/td\u003e\n\u003ctd\u003eChannel 8-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 20\u003c\/td\u003e\n\u003ctd\u003eModule Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 21\u003c\/td\u003e\n\u003ctd\u003eModule Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Location:\u003c\/strong\u003e The module can be installed in any slot of a 1771 I\/O chassis except the leftmost slot, which is reserved for the processor or adapter module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Keying:\u003c\/strong\u003e Mount plastic keying bands on the backplane connector between pins 10 and 12, and between pins 24 and 26.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Use shielded cable (e.g., Belden 8761) and ground the foil shield and drain wire at the 1771 I\/O chassis ground stud or mounting bolt only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Arm:\u003c\/strong\u003e Connect field signal wiring using the 1771-WG Field Wiring Arm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnused Channels:\u003c\/strong\u003e Jumper unused channel inputs (+ and -) together and connect them to module common to minimize electrical noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Voltage Limit:\u003c\/strong\u003e Ensure all analog input signals remain within +14.25V DC relative to module common to prevent channel crosstalk.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive (89\/336\/EEC):\u003c\/strong\u003e EN 50081-2 Industrial Emission, EN 50082-2 Industrial Immunity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Voltage Directive (73\/23\/EEC):\u003c\/strong\u003e EN 61131-2 Programmable Controllers.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695193190763,"sku":"1771-IFE","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1771-IFE_003_1200x1200_c9c91a4a-e796-4d4a-8f79-ff2468c24fd2.jpg?v=1786193475","url":"https:\/\/www.plcprotech.com\/products\/allen-bradley-1771-ife-plc-5-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}