{"product_id":"allen-bradley-1783-etap-stratix-2000-ethernet-ip-tap","title":"Allen-Bradley 1783-ETAP Stratix 2000 EtherNet\/IP Tap","description":"\u003cp\u003eThe \u003cstrong\u003e1783-ETAP\u003c\/strong\u003e is a three-port discrete physical layer networking component featuring \u003cstrong\u003eEmbedded Switch Technology\u003c\/strong\u003e to integrate non-switched industrial automation devices directly into linear or Device Level Ring (DLR) network topologies. It provides raw physical layer packet steering and conversion over three copper Ethernet ports, eliminating the need for dedicated multi-port managed switches in basic control zones. The device establishes direct deterministic node aggregation over \u003cstrong\u003eEtherNet\/IP\u003c\/strong\u003e infrastructures to interconnect remote logic chassis, motor control centers, or human-machine interfaces. Powered by a regulated 24 VDC circuit, it features solid-state basic electrical insulation from network-to-power and network-to-network pathways to preserve operational data integrity in high-interference automated manufacturing environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice Level Ring Integration\u003c\/strong\u003e: Enables standard point-to-point hardware terminal nodes to participate directly within single-fault tolerant DLR automation rings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree-Port Copper Grid\u003c\/strong\u003e: Equipped with three independent RJ45 copper ports to route concurrent field signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRigid Signal Isolation\u003c\/strong\u003e: Implements continuous basic type insulation to guard inner control logic against communication channel spikes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Thermal Footprint\u003c\/strong\u003e: Operates efficiently with a maximum power consumption rating of 3 W, reducing internal enclosure heat generation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Temperature Code\u003c\/strong\u003e: Rated with North American and IEC T5 temperature codes for stable execution under restricted environmental parameters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Open Housing\u003c\/strong\u003e: Designed with a space-saving, open-style profile to optimize spatial footprints inside main bay control panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLinear and ring-configured Device Level Ring (DLR) segments in manufacturing zones.\u003c\/li\u003e\n\u003cli\u003eInter-chassis communication bridging for distributed industrial control networks.\u003c\/li\u003e\n\u003cli\u003eDedicated field-level extraction of diagnostic telemetry over discrete copper lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1783-ETAP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnology Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmbedded Switch Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP tap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Copper Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 copper ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTap Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 mA @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Power Supply Input Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC (20.4 to 27.6V DC) Class 2 \/ SELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Isolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30V (continuous), basic insulation type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Boundary Mapping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNetwork channels to power, and network channels to network channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Type Testing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTested at 1250V AC for 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Type Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (open-style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNorth American Temp Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC Temp Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Port Wiring Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Port Wiring Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Specification \/ Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ45 connector compliant with IEC 60603-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Media Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pair or 4-pair Category 5e minimum cable according to TIA 568-B.1, or Category 5 cable according to ISO\/IEC 24702\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Power Connection (Single Wire)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne 0.33 to 3.3 mm2 (22 to 12 AWG) solid or stranded copper wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Power Connection (Dual Wire)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo 0.33 to 1.3 mm2 (22 to 16 AWG) solid or stranded copper wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Conductor Insulation Spec\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRated at 75 degC (167 degF) or greater, 1.2 mm (3\/64 in.) maximum insulation thickness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Screw Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 to 0.8 N m (5 to 7 lb in) on power connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Routing Strategy\u003c\/strong\u003e: Use the designated conductor category rankings (Category 1 for power ports, Category 2 for communication ports) to isolate and plan independent internal cable tray routing paths, minimizing electromagnetic crosstalk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Terminal Torque Bounds\u003c\/strong\u003e: Fasten terminal connection screws strictly within the 0.6 to 0.8 N m window to avoid fracturing copper wire strands or stripping terminal block threads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Environmental Shielding\u003c\/strong\u003e: Because this unit features an open-style enclosure rating, it must be mounted inside a secondary industrial enclosure that provides appropriate environmental protection against dust, humidity, and atmospheric contaminants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Restrictions\u003c\/strong\u003e: Power lines must derive exclusively from a certified 24 VDC Class 2 or Safety Extra-Low Voltage (SELV) rated power supply to prevent overvoltage breakdown.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the minimum cable specification required to establish network connections on this device?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Communication interfaces require a minimum of 2-pair or 4-pair Category 5e cabling conforming to TIA 568-B.1, or standard Category 5 cabling conforming to ISO\/IEC 24702.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can two independent wires be landed into a single terminal point on the DC power block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the power terminal block can accept two solid or stranded copper wires simultaneously, provided their individual cross-sectional sizes fall between 0.33 and 1.3 mm2 (22 to 16 AWG).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What isolation metrics are verified between the internal communication channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The tap is factory type-tested at 1250V AC for 60 seconds, maintaining a continuous 30V basic insulation barrier between network channels and power, as well as between separate network channels.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695183098219,"sku":"1783-ETAP","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1783-etap-3-port-ethernet-jg35wr3d5py_d5c62f4a-8ea1-467a-80de-703eb98bf4d8.jpg?v=1766114365","url":"https:\/\/www.plcprotech.com\/products\/allen-bradley-1783-etap-stratix-2000-ethernet-ip-tap","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}