{"product_id":"allen-bradley-1783-ms06t-stratix-8000-6-port-managed-switch","title":"Allen-Bradley 1783-MS06T Stratix 8000 6 Port Managed Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1783-MS06T\u003c\/strong\u003e is a Stratix 8000 Layer 2 6-port managed Ethernet switch engineered for industrial networking applications. The \u003cstrong\u003e1783-MS06T\u003c\/strong\u003e switch provides secure, high-performance connectivity within plant-floor environments and industrial control networks.\u003c\/p\u003e\n\u003cp\u003eDesigned with an open-style enclosure, the device supports DC power inputs ranging from 18 to 60V DC (Class 2\/SELV) with a maximum input rating of 2 A and maximum power dissipation of 15.7 W. It features RJ45 Ethernet connectors compliant with IEC 60603-7, supporting Category 5e minimum or Category 5 cabling. The module also provides basic isolation rated at 75V continuous between power and ground, power to network channels, and power to alarm ports.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLayer 2 managed switch functionality with 6 Ethernet ports.\u003c\/li\u003e\n\u003cli\u003eOperating power input rating of 2 A max at 18...60V DC, Class 2\/SELV.\u003c\/li\u003e\n\u003cli\u003eMaximum power dissipation of 15.7 W.\u003c\/li\u003e\n\u003cli\u003eAlarm relay output rated at 1 A max at 30V DC, Class 2\/SELV.\u003c\/li\u003e\n\u003cli\u003eRJ45 Ethernet connection using Category 5e minimum (TIA 568-B.1) or Category 5 (ISO\/IEC 24702) cabling.\u003c\/li\u003e\n\u003cli\u003eDedicated terminal connections for DC power, alarm relay, and functional ground.\u003c\/li\u003e\n\u003cli\u003eOpen-style enclosure with T4 North American and IEC temperature codes.\u003c\/li\u003e\n\u003cli\u003eCompatible with optional Stratix expansion modules (such as 1783-MX08T, 1783-MX08F, 1783-MX04S, 1783-MX08S, 1783-MX04E, and 1783-MX04T04E).\u003c\/li\u003e\n\u003cli\u003eCompatible with optional SFP modules (1783-SFP100FX, 1783-SFP1GSX, 1783-SFP100LX, 1783-SFP1GLX) and memory cards (1783-RMCF, 1783-MCF).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial EtherNet\/IP control networks.\u003c\/li\u003e\n\u003cli\u003ePlant-floor automation and distributed control systems.\u003c\/li\u003e\n\u003cli\u003eHarsh industrial environments requiring wide operating temperature ranges.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1783-MS06T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitch Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStratix 8000 Managed Switch, Layer 2 (6 ports)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitch Input Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A max @ 18...60V DC, Class 2\/SELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Relay Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 A max @ 30V DC, Class 2\/SELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75V (continuous), basic insulation type (power to ground, power to network channels, power to alarm); Type tested at 1000V AC for 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ45 connector per IEC 60603-7; 2- or 4-pair Cat 5e minimum (TIA 568-B.1) or Cat 5 (ISO\/IEC 24702)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Power \u0026amp; Alarm Wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5...0.8 mm² (20...18 AWG) solid or stranded copper wire rated at 90 degC or greater, 1.2 mm insulation max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Ground Wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3...5.3 mm² (12...10 AWG) solid or stranded copper wire rated at 75 degC or greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.23 N-m (2.0 lb-in) on power and alarm connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-on alarm ports, 2-on power ports, 2-on Ethernet ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Type Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (open-style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNorth American Temp Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC Temp Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...60 degC (-40...140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Surrounding Air Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 degC (140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNonoperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...85 degC (-40...185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 g @ 10...500 Hz (IEC 60068-2-6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 g (IEC 60068-2-27)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNonoperating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 g (IEC 60068-2-27)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEmissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCISPR11 (IEC 61000-6-4) Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESD Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV contact discharges, 15 kV air discharges (IEC 61000-4-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadiated RF Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20V\/m (80...1000 MHz), 10V\/m (900 MHz, 1890 MHz, 1000...2700 MHz) (IEC 61000-4-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEFT\/B Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±4 kV @ 2.5 kHz and ±2 kV @ 5 kHz on power, alarm, and Ethernet ports (IEC 61000-4-4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Transient Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1 kV DM \/ ±2 kV CM on power \u0026amp; alarm ports; ±2 kV CM on Ethernet ports (IEC 61000-4-5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConducted RF Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz (IEC 61000-4-6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMagnetic Field Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 A\/m long duration, 300 A\/m short duration at 50\/60 Hz (IEC 61000-4-8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOscillatory Surge Withstand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kV (IEEE C37.90.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Variation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ms interruption on DC supply ports (IEC 61000-4-29)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.8 cm x 15.3 cm x 11.75 cm (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain unrestricted airflow around the switch by adhering to the minimum clearance distances: top and bottom 105 mm (4.13 in.), left and right 90 mm (3.54 in.), and front 65 mm (2.56 in.).\u003c\/li\u003e\n\u003cli\u003eConnect functional ground using 3.3...5.3 mm² (12...10 AWG) copper wire rated for at least 75 degC.\u003c\/li\u003e\n\u003cli\u003eConnect DC power supply and alarm wiring using 0.5...0.8 mm² (20...18 AWG) copper wire rated for at least 90 degC.\u003c\/li\u003e\n\u003cli\u003eTighten power and alarm connector screws to a torque specification of 0.23 N-m (2.0 lb-in).\u003c\/li\u003e\n\u003cli\u003eFor panel-mounting, ensure tab hole center-to-center spacing on the base unit is 6.83 cm (2.69 in.).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ec-UL-us:\u003c\/strong\u003e UL Listed Industrial Control Equipment (File E65584); UL Listed for Class I, Division 2 Group A, B, C, D Hazardous Locations (File E194810).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Union EMC Directive (2004\/108\/EC) compliant with EN 61326-1, EN 61000-6-2, EN 61000-6-4, EN 61131-2; RoHS Directive (2011\/65\/EU) compliant with EN 50581.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC-Tick:\u003c\/strong\u003e Australian Radiocommunications Act compliant with AS\/NZS CISPR 11.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEx (ATEX):\u003c\/strong\u003e European Union ATEX Directive (94\/9\/EC) compliant with EN 60079-15, EN 60079-0 (II 3 G Ex nA nC IIC T4 Gc).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC:\u003c\/strong\u003e Korean Certification of Broadcasting and Communications Equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP:\u003c\/strong\u003e ODVA conformance tested to EtherNet\/IP specifications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53685400469867,"sku":"1783-MS06T","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1783-MS06T_001_1200x1200_f984cc9d-2dfd-4ef7-83f9-8078af1e0f5b.jpg?v=1786189182","url":"https:\/\/www.plcprotech.com\/products\/allen-bradley-1783-ms06t-stratix-8000-6-port-managed-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}