{"product_id":"allen-bradley-2094-bc02-m02-m-kinetix-6200-integrated-axis-power-module","title":"Allen-Bradley 2094-BC02-M02-M Kinetix 6200 Integrated Axis Power Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e2094-BC02-M02-M\u003c\/strong\u003e is a \u003cstrong\u003eKinetix 6200 Integrated Axis Power Module\u003c\/strong\u003e combining converter and inverter circuitry within one drive assembly. It operates on 400V AC class input power and is designed to function with one control module.\u003c\/p\u003e\n\u003cp\u003eThe module provides integrated motion control for servo motor and drive applications. Its integrated safety architecture supports Safe Torque-Off and Safe Speed Monitoring functions without requiring a separate external safety monitor.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eIntegrated Axis Module\u003c\/strong\u003e can operate with Kinetix 6200 axis modules and the Kinetix 600M integrated drive-motor system. The supplied technical information also identifies compatibility with Kinetix 6000 servo-drive migration applications.\u003c\/p\u003e\n\u003cp\u003eThe module supports SERCOS-based motion architecture and EtherNet\/IP network integration. Diagnostic functions display fault messages to assist troubleshooting and system maintenance.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated converter and inverter circuitry\u003c\/li\u003e\n\u003cli\u003eDesigned for one control module\u003c\/li\u003e\n\u003cli\u003eIntegrated Safe Speed Monitor\u003c\/li\u003e\n\u003cli\u003eSafe Torque-Off operating mode\u003c\/li\u003e\n\u003cli\u003eSafe Maximum Speed monitoring\u003c\/li\u003e\n\u003cli\u003eSafe Maximum Acceleration monitoring\u003c\/li\u003e\n\u003cli\u003eSafe Direction monitoring\u003c\/li\u003e\n\u003cli\u003eZero Speed monitoring\u003c\/li\u003e\n\u003cli\u003eEnabling Switch Control\u003c\/li\u003e\n\u003cli\u003eDoor monitoring and control\u003c\/li\u003e\n\u003cli\u003eSolid-state motor short-circuit protection\u003c\/li\u003e\n\u003cli\u003eFault-message diagnostic display\u003c\/li\u003e\n\u003cli\u003eModular drive-system construction\u003c\/li\u003e\n\u003cli\u003eCompatible with Kinetix 600M integrated drive-motor systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-axis servo motion systems\u003c\/li\u003e\n\u003cli\u003eAutomated production machinery\u003c\/li\u003e\n\u003cli\u003ePackaging and material-handling equipment\u003c\/li\u003e\n\u003cli\u003eMachine-tool motion control\u003c\/li\u003e\n\u003cli\u003ePrinting and converting machinery\u003c\/li\u003e\n\u003cli\u003eAssembly-line positioning systems\u003c\/li\u003e\n\u003cli\u003eSafety-monitored maintenance operations\u003c\/li\u003e\n\u003cli\u003eKinetix 6000 drive-system migration projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e2094-BC02-M02-M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eKinetix 6200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIntegrated Axis Power Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e884951092518\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e13.00 lb (5.90 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Module Requirement\u003c\/td\u003e\n\u003ctd\u003eOne control module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e400\/460V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Drive Input\u003c\/td\u003e\n\u003ctd\u003e360-480V AC, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Power\u003c\/td\u003e\n\u003ctd\u003e6.6 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Section Output\u003c\/td\u003e\n\u003ctd\u003e15 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Bus Capacitance\u003c\/td\u003e\n\u003ctd\u003e8955 microfarads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e36-75 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Section Heat Dissipation\u003c\/td\u003e\n\u003ctd\u003e44 W at 20% loading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Section Heat Dissipation\u003c\/td\u003e\n\u003ctd\u003e72 W at 40% loading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnvironmental and Installation\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0-50 degC (32-122 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Clearance\u003c\/td\u003e\n\u003ctd\u003e80 mm (3.10 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Enclosure Depth\u003c\/td\u003e\n\u003ctd\u003e302 mm (11.9 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eCircuit Protection\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Available Fault Current with Fuse Protection\u003c\/td\u003e\n\u003ctd\u003e200,000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Available Fault Current with Circuit-Breaker Protection\u003c\/td\u003e\n\u003ctd\u003e65,000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Input Fuse\u003c\/td\u003e\n\u003ctd\u003eFNQ-R-10, 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternative Control Input Fuse\u003c\/td\u003e\n\u003ctd\u003eFNQ-R-7.5, 7.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Two-Pole Circuit Breaker\u003c\/td\u003e\n\u003ctd\u003e1492-SPM2D060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Single-Pole Circuit Breaker\u003c\/td\u003e\n\u003ctd\u003e1492-SPM1D150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended DC Bus Fuse\u003c\/td\u003e\n\u003ctd\u003eFWJ-40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternative DC Bus Fuse\u003c\/td\u003e\n\u003ctd\u003eA70QS40-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eAC Line Filter\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended AC Line Filter\u003c\/td\u003e\n\u003ctd\u003e2090-XXLF-X330B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Input Voltage\u003c\/td\u003e\n\u003ctd\u003e500V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Current\u003c\/td\u003e\n\u003ctd\u003e30 A at 50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Weight\u003c\/td\u003e\n\u003ctd\u003e2.7 kg (5.9 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module with the specified branch-circuit protection.\u003c\/li\u003e\n\u003cli\u003eMaintain at least 80 mm (3.10 in.) of installation clearance.\u003c\/li\u003e\n\u003cli\u003eUse an enclosure with a minimum depth of 302 mm (11.9 in.).\u003c\/li\u003e\n\u003cli\u003eSelect the control-input fuse according to the specified circuit arrangement.\u003c\/li\u003e\n\u003cli\u003eApply the recommended DC bus fuse where DC bus protection is required.\u003c\/li\u003e\n\u003cli\u003eUse the specified AC line filter when line filtering is required.\u003c\/li\u003e\n\u003cli\u003eVerify that the supply voltage remains within the stated 360-480V AC, 3-phase range.\u003c\/li\u003e\n\u003cli\u003eProvide suitable panel ventilation for operation between 0 and 50 degC.\u003c\/li\u003e\n\u003cli\u003eConfirm that the available fault current does not exceed the stated fuse or circuit-breaker rating.\u003c\/li\u003e\n\u003cli\u003eFollow the applicable Kinetix installation procedures for grounding, power wiring, and control-module attachment.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695173169515,"sku":"2094-BC02-M02-M","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-2094-bc02-m02-m-integrated-axis-module-f2neplzdsex_9da588e2-896e-439f-ae7a-16ac93008314.jpg?v=1766114119","url":"https:\/\/www.plcprotech.com\/products\/allen-bradley-2094-bc02-m02-m-kinetix-6200-integrated-axis-power-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}