{"product_id":"allen-bradley-2094-bl10s-kinetix-line-interface-module","title":"Allen-Bradley 2094-BL10S Kinetix Line Interface Module","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 2094-BL10S\u003c\/strong\u003e is a Kinetix line interface module designed to replace multiple common-input power devices required for servo drive systems. Operating with an input voltage of 460V AC and a current rating of 10A, this module integrates essential branch circuit protection, power outputs, and filtering capabilities into a single unit. The \u003cstrong\u003e2094-BL10S\u003c\/strong\u003e simplifies system installation and panel layouts by providing customer-configurable branch-circuit protection and an internal step-down transformer for control power. It provides 24V DC power output with a 20A current capacity for I\/O and brake functions, an internal 24V DC I\/O line filter, and an internal 230V AC control line filter to ensure electrical noise isolation.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to replace multiple common-input power components in servo drive systems.\u003c\/li\u003e\n\u003cli\u003eCustomer-configurable branch-circuit protection allowing connection of CB2 and CB3 before or after the main disconnect.\u003c\/li\u003e\n\u003cli\u003eIntegrated 24V DC power supply with a 20A current capacity for I\/O and motor brake applications.\u003c\/li\u003e\n\u003cli\u003eEquipped with internal step-down transformer to derive control power from the 460V AC main input.\u003c\/li\u003e\n\u003cli\u003eContains internal 24V DC I\/O line filter and internal 230V AC control line filter for noise conditioning.\u003c\/li\u003e\n\u003cli\u003eFeatures safety-rated, positively-guided, and mechanically-latched auxiliary contacts on the line contactor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMotion control systems utilizing Bulletin 2093 or 2094 power rails.\u003c\/li\u003e\n\u003cli\u003eIndustrial servo drive systems requiring integrated line interface and power distribution.\u003c\/li\u003e\n\u003cli\u003eAutomated machinery requiring safety-rated main power disconnection and contactor monitoring.\u003c\/li\u003e\n\u003cli\u003eMulti-axis drive systems needing electrical noise zone segregation and filter management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2094-BL10S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKinetix Line Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e460V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Power Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC (20 A current capacity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Line Filter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal 230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Line Filter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Filter (3-Phase)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal (customer supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor Coil Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC via internal DC interface module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 normally-closed (NC) safety-rated auxiliary contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-Safety Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 normally-open (NO) auxiliary contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Make (ALRM_M), 1 Break (ALRM_B), 1 Common (ALRM_COM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit Breakers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB1 (Main Disconnect), CB2 (Control\/AUX), CB3 (24V Supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUPC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e820919707841\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ch4\u003eIOL (21-pin) Status I\/O Connector\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSignal\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIO 24V supply\u003c\/td\u003e\n\u003ctd\u003eIO_PWR1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIO 24V common\u003c\/td\u003e\n\u003ctd\u003eIO_COM1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIO 24V supply\u003c\/td\u003e\n\u003ctd\u003eIO_PWR1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIO 24V common\u003c\/td\u003e\n\u003ctd\u003eIO_COM1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIO 24V supply\u003c\/td\u003e\n\u003ctd\u003eIO_PWR1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIO 24V common\u003c\/td\u003e\n\u003ctd\u003eIO_COM1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e7\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V contactor coil positive\u003c\/td\u003e\n\u003ctd\u003eCOIL_E1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V contactor coil negative\u003c\/td\u003e\n\u003ctd\u003eCOIL_E2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e9\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm make contact (CB1)\u003c\/td\u003e\n\u003ctd\u003eALRM_M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShield\u003c\/td\u003e\n\u003ctd\u003eSHIELD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e11\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm break contact (CB1)\u003c\/td\u003e\n\u003ctd\u003eALRM_B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm common (CB1)\u003c\/td\u003e\n\u003ctd\u003eALRM_COM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e13\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor auxiliary contact (NC) #1 IN\u003c\/td\u003e\n\u003ctd\u003eCONSTAT_11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e14\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor auxiliary contact (NC) #1 OUT\u003c\/td\u003e\n\u003ctd\u003eCONSTAT_12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e15\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor auxiliary contact (NC) #2 IN\u003c\/td\u003e\n\u003ctd\u003eCONSTAT_21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e16\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor auxiliary contact (NC) #2 OUT\u003c\/td\u003e\n\u003ctd\u003eCONSTAT_22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e17\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor auxiliary contact (NC) #3 IN\u003c\/td\u003e\n\u003ctd\u003eCONSTAT_31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e18\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor auxiliary contact (NC) #3 OUT\u003c\/td\u003e\n\u003ctd\u003eCONSTAT_32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e19\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor auxiliary contact (NO) #5 IN\u003c\/td\u003e\n\u003ctd\u003eCONSTAT_53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor auxiliary contact (NO) #5 OUT\u003c\/td\u003e\n\u003ctd\u003eCONSTAT_54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e21\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShield\u003c\/td\u003e\n\u003ctd\u003eSHIELD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eIPL (4-pin) VAC LINE Input Power Connector\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSignal\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChassis ground\u003c\/td\u003e\n\u003ctd\u003ePE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-phase input power L3\u003c\/td\u003e\n\u003ctd\u003eL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-phase input power L2\u003c\/td\u003e\n\u003ctd\u003eL2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-phase input power L1\u003c\/td\u003e\n\u003ctd\u003eL1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eOPL (4-pin) VAC LOAD Output Power Connector\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSignal\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChassis ground\u003c\/td\u003e\n\u003ctd\u003ePE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-phase output power L3\u003c\/td\u003e\n\u003ctd\u003eL3'\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-phase output power L2\u003c\/td\u003e\n\u003ctd\u003eL2'\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-phase output power L1\u003c\/td\u003e\n\u003ctd\u003eL1'\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eP1L (6-pin) Brake and I\/O Power Output Connector\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSignal\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+24V DC supply\u003c\/td\u003e\n\u003ctd\u003eIO_PWR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+24V DC common\u003c\/td\u003e\n\u003ctd\u003eIO_COM2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+24V DC supply\u003c\/td\u003e\n\u003ctd\u003eIO_PWR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+24V DC common\u003c\/td\u003e\n\u003ctd\u003eIO_COM2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+24V DC supply\u003c\/td\u003e\n\u003ctd\u003eIO_PWR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+24V DC common\u003c\/td\u003e\n\u003ctd\u003eIO_COM2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eP2L (4-pin) Auxiliary Power Output Connector\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSignal\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230V AC power supply\u003c\/td\u003e\n\u003ctd\u003eAUX2_L1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230V AC power supply\u003c\/td\u003e\n\u003ctd\u003eAUX2_L2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230V AC power supply\u003c\/td\u003e\n\u003ctd\u003eAUX1_L1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230V AC power supply\u003c\/td\u003e\n\u003ctd\u003eAUX1_L2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eCPL (2-pin) Control Power Output Connector\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSignal\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControl power output\u003c\/td\u003e\n\u003ctd\u003eCTRL_1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControl power output\u003c\/td\u003e\n\u003ctd\u003eCTRL_2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Requirements:\u003c\/strong\u003e The device must be mounted in a grounded conductive enclosure offering protection to IP55 to comply with UL and CE requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Surface:\u003c\/strong\u003e Install the module inside the enclosure on a flat, rigid, vertical surface that is free from shock, vibration, moisture, oil mist, dust, or corrosive vapors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Position:\u003c\/strong\u003e Mount the module exclusively in an upright position; do not mount the module on its side.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow Clearances:\u003c\/strong\u003e Maintain a minimum clearance of 50.8 mm (2.0 inches) above and below the module for airflow and system access. A minimum cabinet depth clearance of 250 mm (9.8 inches) is required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Performance:\u003c\/strong\u003e Mount the line interface module on the same panel as the drive and as close to the drive as possible to minimize electrical noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Requirements:\u003c\/strong\u003e Use copper wire rated for a minimum of 75 degC. Secure connections according to these explicit specifications:\n\u003cul\u003e\n\u003cli\u003e\n\u003ci\u003eIPL \/ OPL Connectors:\u003c\/i\u003e Wire size 2.5 to 25 mm² (14 to 4 AWG), strip length 16.0 mm (0.63 in), torque value 2.7 N-m (24 lb-in).\u003c\/li\u003e\n\u003cli\u003e\n\u003ci\u003eCPL \/ P2L Connectors:\u003c\/i\u003e Wire size 0.2 to 4.0 mm² (24 to 10 AWG), strip length 7.0 mm (0.28 in), torque value 0.5 to 0.6 N-m (4.4 to 5.3 lb-in).\u003c\/li\u003e\n\u003cli\u003e\n\u003ci\u003eP1L Connector:\u003c\/i\u003e Wire size 0.08 to 1.5 mm² (28 to 16 AWG), strip length 7.0 mm (0.28 in), torque value 0.22 to 0.25 N-m (1.9 to 2.2 lb-in).\u003c\/li\u003e\n\u003cli\u003e\n\u003ci\u003eIOL Connector:\u003c\/i\u003e Wire size 0.5 to 1.5 mm² (22 to 14 AWG), strip length 6.0 mm (0.25 in), torque value 1.13 N-m (10 lb-in).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the chassis earth ground connection is properly established from a grounded power configuration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695183262059,"sku":"2094-BL10S","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-2094-bl10s-line-interface-module-c2sxqi3ihu0_0596be81-774f-4c00-9d58-994959bb9ea8.jpg?v=1766114370","url":"https:\/\/www.plcprotech.com\/products\/allen-bradley-2094-bl10s-kinetix-line-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}