{"product_id":"allen-bradley-2094-bm02-m-kinetix-6200-multi-axis-servo-drive","title":"Allen-Bradley 2094-BM02-M Kinetix 6200 Multi-axis Servo Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 2094-BM02-M\u003c\/strong\u003e is a Kinetix 6200 modular multi-axis servo drive designed to provide Integrated Motion capability for motor or drive applications. As an Axis Module (AM), it operates with 460V three-phase nominal drive voltage (360–480V AC input) and features a 15A inverter section. This module requires one control module and operates in conjunction with an Integrated Axis Module (IAM) power module on a shared power rail system.\u003c\/p\u003e\n\u003cp\u003eEngineered for seamless architectural transitions, the \u003cstrong\u003e2094-BM02-M\u003c\/strong\u003e allows systems to transition smoothly from Safe Torque Off to Safe Speed Monitor functionalities, and migrate from SERCOS interfaces to EtherNet\/IP networks. It maintains full compatibility with the Kinetix 6000 servo drive family, enabling clean hardware migration whenever application requirements advance. The embedded safety design eliminates the need for an external safety monitor, reducing hardware layout footprints and simplifying wiring architectures. Crucially, the Safe Speed Monitor feature permits crucial machine maintenance work without necessitating a complete machine shutdown, maximizing uptime, minimizing energy and production waste, and boosting overall operating efficiency.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Multi-Axis Architecture:\u003c\/strong\u003e Integrates easily onto a shared 2094 power rail alongside an IAM module, minimizing spare parts inventory and wiring complexity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Embedded Safety:\u003c\/strong\u003e Integrated safety functions eliminate external safety modules while providing comprehensive personnel protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Safety Suite:\u003c\/strong\u003e Supports Safe Torque Off, Safe Speed Monitor, Safe Maximum Speed, Safe Maximum Acceleration Monitoring, Safe Direction Monitoring, Zero Speed Monitoring, Enabling Switch Control, and Door Monitoring and Control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork \u0026amp; Interface Flexibility:\u003c\/strong\u003e Enables direct migration path between SERCOS interface and EtherNet\/IP communication networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Diagnostics:\u003c\/strong\u003e Features an onboard diagnostic display that communicates the exact nature of system faults via descriptive error messages.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-axis industrial servo motor controls\u003c\/li\u003e\n\u003cli\u003eAutomated assembly lines and packaging systems\u003c\/li\u003e\n\u003cli\u003eMaterial handling and continuous production machinery\u003c\/li\u003e\n\u003cli\u003eIntegrated motion control over SERCOS and EtherNet\/IP networks\u003c\/li\u003e\n\u003cli\u003eMaintenance-heavy automated zones requiring Safe Speed monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKinetix 6200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2094-BM02-M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUPC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e884951092549\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Module Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAxis Module (AM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Drive Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e360–480 Volts AC (3-Phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e460 Volts AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 Amperes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWattage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.6 kWatts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 to 122 F (0 to 50 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Bus Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.00 lbs (3.18 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.76 x 11.9 x 13.2 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Rail Mounting:\u003c\/strong\u003e The module must be installed on a compatible Bulletin 2094 power rail. Hang the module's mounting bracket from the slot on the power rail and align the rear guide pins carefully before tightening the mounting screws to 2.26 N•m (20 lb•in) torque.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Frequency (HF) Bonding:\u003c\/strong\u003e Ensure proper HF bonding of the power rail and enclosures to a central subpanel ground point to mitigate electromagnetic interference (EMI) and radio frequency interference (RFI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Requirements:\u003c\/strong\u003e Utilize the provided 100 mm (3.9 in.) braided copper ground strap to connect the power rail or mounting brackets to the bonded cabinet chassis ground bus. All electrical ground paths must conform strictly to local regulations and the National Electrical Code (NEC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Management \u0026amp; Shielding:\u003c\/strong\u003e Copper wires with a minimum rating of 75 degC must be used for power connections. Securely fasten all motor power cable shields using the designated shield clamp assembly to minimize stray electrical noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Clearance:\u003c\/strong\u003e Maintain recommended structural clearances around the drive power rail assembly to allow adequate vertical air flow and thermal cooling within the cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695182180715,"sku":"2094-BM02-M","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-2094-bm02-m-axis-module-wf2khydrov5_cf5e5886-6de6-4422-91df-fc9c315c1f6c.jpg?v=1766114331","url":"https:\/\/www.plcprotech.com\/products\/allen-bradley-2094-bm02-m-kinetix-6200-multi-axis-servo-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}