{"product_id":"allen-bradley-2094-bmp5-m-kinetix-6200-and-kinetix-6500-axis-module","title":"Allen-Bradley 2094-BMP5-M Kinetix 6200 and Kinetix 6500 Axis Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e2094-BMP5-M\u003c\/strong\u003e is a Bulletin 2094 axis module for \u003cstrong\u003eKinetix 6200\u003c\/strong\u003e and \u003cstrong\u003eKinetix 6500\u003c\/strong\u003e modular multi-axis servo drives. It contains the inverter power section required to operate an individual servo axis.\u003c\/p\u003e\n\u003cp\u003eThe module uses a nominal 650V DC input and provides 1.8 kW nominal continuous output power. Its current and velocity control loops regulate the inverter output according to the configured motion application.\u003c\/p\u003e\n\u003cp\u003eAn internal shunt circuit manages regenerative energy returned to the DC bus. The same inverter section is incorporated within the 2094-BC01-MP5-M integrated axis module.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBulletin 2094 axis-module inverter section\u003c\/li\u003e\n\u003cli\u003eCompatible with Kinetix 6200 modular multi-axis servo drives\u003c\/li\u003e\n\u003cli\u003eCompatible with Kinetix 6500 modular multi-axis servo drives\u003c\/li\u003e\n\u003cli\u003eSeparate velocity-loop and current-loop control\u003c\/li\u003e\n\u003cli\u003eIntegrated internal shunt circuit\u003c\/li\u003e\n\u003cli\u003eCorresponding inverter section used in the 2094-BC01-MP5-M IAM\u003c\/li\u003e\n\u003cli\u003eSelected according to application inverter power requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModular multi-axis servo drive systems\u003c\/li\u003e\n\u003cli\u003eIndividual servo-axis power control\u003c\/li\u003e\n\u003cli\u003eCoordinated machine motion\u003c\/li\u003e\n\u003cli\u003eAutomated positioning equipment\u003c\/li\u003e\n\u003cli\u003ePackaging machinery\u003c\/li\u003e\n\u003cli\u003eMaterial handling systems\u003c\/li\u003e\n\u003cli\u003eAssembly machinery\u003c\/li\u003e\n\u003cli\u003eConverting equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2094-BMP5-M\u003c\/td\u003e\n\u003ctd\u003eBulletin 2094 460V Axis Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2094-BC01-MP5-M\u003c\/td\u003e\n\u003ctd\u003eIAM power module containing the corresponding inverter section\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eDrive and Control\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e2094-BMP5-M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAxis Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Function\u003c\/td\u003e\n\u003ctd\u003eInverter power section\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Drive Families\u003c\/td\u003e\n\u003ctd\u003eKinetix 6200 and Kinetix 6500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBulletin\u003c\/td\u003e\n\u003ctd\u003e2094\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Class\u003c\/td\u003e\n\u003ctd\u003e460V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity Loop Bandwidth\u003c\/td\u003e\n\u003ctd\u003e500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Loop Bandwidth\u003c\/td\u003e\n\u003ctd\u003e1300 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWM Frequency\u003c\/td\u003e\n\u003ctd\u003e8 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eElectrical Ratings\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e650V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current, rms\u003c\/td\u003e\n\u003ctd\u003e2.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current, sine 0-pk\u003c\/td\u003e\n\u003ctd\u003e4.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Current, rms\u003c\/td\u003e\n\u003ctd\u003e7.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Current, 0-pk\u003c\/td\u003e\n\u003ctd\u003e9.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Continuous Output Power\u003c\/td\u003e\n\u003ctd\u003e1.8 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e98%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Current Rating\u003c\/td\u003e\n\u003ctd\u003e200,000 A rms symmetrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eInternal Shunt\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Shunt Power\u003c\/td\u003e\n\u003ctd\u003e50 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Shunt Power\u003c\/td\u003e\n\u003ctd\u003e5.6 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Shunt Resistance\u003c\/td\u003e\n\u003ctd\u003e115 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShunt Turn-On Voltage\u003c\/td\u003e\n\u003ctd\u003e805V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShunt Turn-Off Voltage\u003c\/td\u003e\n\u003ctd\u003e765V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eDC Bus Energy Storage\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e75 uF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitive Energy Absorption\u003c\/td\u003e\n\u003ctd\u003e10 J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the catalog number before installing the axis module.\u003c\/li\u003e\n\u003cli\u003eSelect the module according to the application inverter power requirements.\u003c\/li\u003e\n\u003cli\u003eInstall the module only within a compatible Bulletin 2094 drive system.\u003c\/li\u003e\n\u003cli\u003eVerify Kinetix 6200 or Kinetix 6500 system compatibility.\u003c\/li\u003e\n\u003cli\u003eConfirm the power rail and adjacent module arrangement before installation.\u003c\/li\u003e\n\u003cli\u003eMaintain sufficient connector clearance for the required cable bend radius.\u003c\/li\u003e\n\u003cli\u003eVerify motor power and feedback connections before applying power.\u003c\/li\u003e\n\u003cli\u003eFollow the applicable drive user manual during installation and commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695191126379,"sku":"2094-BMP5-M","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-2094-bmp5-m-power-module-dhv25r3ddqy_c7fc1e25-2c6a-468a-b36f-68db63a54b0b.jpg?v=1766114633","url":"https:\/\/www.plcprotech.com\/products\/allen-bradley-2094-bmp5-m-kinetix-6200-and-kinetix-6500-axis-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}