{"product_id":"allen-bradley-2711p-rp1x-panelview-plus-700-to-1500-logic-module","title":"Allen-Bradley 2711P-RP1X PanelView Plus 700 to 1500 Logic Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e2711P-RP1X\u003c\/strong\u003e is a logic module family for Allen-Bradley PanelView Plus 700 to 1500 terminals. It attaches to the rear of the display module and provides the terminal processing, memory, communication, firmware, and operating-system functions.\u003c\/p\u003e\n\u003cp\u003eThe logic module includes 64 MB internal CompactFlash memory and 64 MB RAM. Its external connections include an Ethernet port, a serial port, two USB ports, and a CompactFlash card slot. Status indicators provide operating information for the installed terminal.\u003c\/p\u003e\n\u003cp\u003eThe official installation document uses \u003cstrong\u003e2711P-RP1x\u003c\/strong\u003e as the family designation. Individual module revisions are identified by their series suffix.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for PanelView Plus 700 to 1500 terminals\u003c\/li\u003e\n\u003cli\u003e64 MB internal CompactFlash memory\u003c\/li\u003e\n\u003cli\u003e64 MB RAM\u003c\/li\u003e\n\u003cli\u003eEthernet communication port\u003c\/li\u003e\n\u003cli\u003eSerial communication port\u003c\/li\u003e\n\u003cli\u003eTwo USB ports\u003c\/li\u003e\n\u003cli\u003eCompactFlash card slot\u003c\/li\u003e\n\u003cli\u003eIntegrated status indicators\u003c\/li\u003e\n\u003cli\u003eReplaceable RAM module\u003c\/li\u003e\n\u003cli\u003eReplaceable internal CompactFlash card\u003c\/li\u003e\n\u003cli\u003eRear-mounted connection to the display module\u003c\/li\u003e\n\u003cli\u003eField-installable module construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePanelView Plus terminal logic-module replacement\u003c\/li\u003e\n\u003cli\u003eIndustrial machine operator interfaces\u003c\/li\u003e\n\u003cli\u003eManufacturing HMI stations\u003c\/li\u003e\n\u003cli\u003eProduction-line visualization terminals\u003c\/li\u003e\n\u003cli\u003eProcess equipment operator panels\u003c\/li\u003e\n\u003cli\u003eExisting PanelView Plus system maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Family\u003c\/td\u003e\n\u003ctd\u003e2711P-RP1x\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLogic Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Terminal Range\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus 700 to 1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Location\u003c\/td\u003e\n\u003ctd\u003eRear of the display module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eMemory\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal CompactFlash\u003c\/td\u003e\n\u003ctd\u003e64 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM\u003c\/td\u003e\n\u003ctd\u003e64 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM Type\u003c\/td\u003e\n\u003ctd\u003eSODIMM RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware Storage\u003c\/td\u003e\n\u003ctd\u003eInternal CompactFlash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating System Storage\u003c\/td\u003e\n\u003ctd\u003eInternal CompactFlash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eModule Series\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003cth\u003eModule Designation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries A\u003c\/td\u003e\n\u003ctd\u003e2711P-RP1x\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries B\u003c\/td\u003e\n\u003ctd\u003e2711P-RP1x\/B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries C\u003c\/td\u003e\n\u003ctd\u003e2711P-RP1x\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries D\u003c\/td\u003e\n\u003ctd\u003e2711P-RP1x\/D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries E\u003c\/td\u003e\n\u003ctd\u003e2711P-RP1x\/E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries F\u003c\/td\u003e\n\u003ctd\u003e2711P-RP1xx\/F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries G\u003c\/td\u003e\n\u003ctd\u003e2711P-RP1xxx\/G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port\u003c\/td\u003e\n\u003ctd\u003eEthernet network connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Port\u003c\/td\u003e\n\u003ctd\u003eSerial communication connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Ports\u003c\/td\u003e\n\u003ctd\u003eTwo USB device connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompactFlash Card Slot\u003c\/td\u003e\n\u003ctd\u003eExternal CompactFlash card access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal CompactFlash Interface\u003c\/td\u003e\n\u003ctd\u003eFirmware and operating-system storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Module Connectors\u003c\/td\u003e\n\u003ctd\u003eConnection between the logic module and display module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eModule operating-status indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all power from the terminal before installing or replacing the module.\u003c\/li\u003e\n\u003cli\u003eDisconnect all power and communication cables before module removal.\u003c\/li\u003e\n\u003cli\u003eWear a properly grounded ESD wristband.\u003c\/li\u003e\n\u003cli\u003eWork in a static-free environment.\u003c\/li\u003e\n\u003cli\u003eAvoid touching exposed electronic components.\u003c\/li\u003e\n\u003cli\u003eInstall the RAM and internal CompactFlash before attaching the logic module when supplied separately.\u003c\/li\u003e\n\u003cli\u003ePlace the display module face-down on a clean, flat, stable surface.\u003c\/li\u003e\n\u003cli\u003eAlign the two logic-module connectors with the display-module connectors.\u003c\/li\u003e\n\u003cli\u003ePress the logic module down until it is firmly seated.\u003c\/li\u003e\n\u003cli\u003eTighten the six captive screws to 0.58 N m (5 to 7 lb in).\u003c\/li\u003e\n\u003cli\u003eRemove any attached communication module before replacing the logic module.\u003c\/li\u003e\n\u003cli\u003eReinstall the communication module after the logic module is securely mounted.\u003c\/li\u003e\n\u003cli\u003eVerify the logic-module series before transferring RAM or internal CompactFlash components.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695173824875,"sku":"2711P-RP1X","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-2711p-rp1x-logic-module-nvmgpk0hmmd_e77851a3-1ed7-4c37-8c67-5a3b6e11ba81.jpg?v=1766114149","url":"https:\/\/www.plcprotech.com\/products\/allen-bradley-2711p-rp1x-panelview-plus-700-to-1500-logic-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}