{"product_id":"allen-bradley-2711p-rp8d-panelview-plus-6-700-1500-logic-module","title":"Allen-Bradley 2711P-RP8D PanelView Plus 6 700-1500 Logic Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e2711P-RP8D\u003c\/strong\u003e is a DC-powered \u003cstrong\u003elogic module\u003c\/strong\u003e for \u003cstrong\u003ePanelView Plus 6 700-1500 terminals\u003c\/strong\u003e. It provides the processing, memory, operating system, communication, and storage functions required by the operator interface terminal.\u003c\/p\u003e\n\u003cp\u003eThe module attaches to a compatible 700, 1000, 1250, or 1500 display module. The modular construction supports field installation, component replacement, and terminal configuration without replacing the complete operator interface.\u003c\/p\u003e\n\u003cp\u003eThe logic module runs FactoryTalk View Machine Edition applications under Windows CE 6.0. It supports FactoryTalk ViewPoint for browser-based access to a running HMI application.\u003c\/p\u003e\n\u003cp\u003eBuilt-in communication resources include Ethernet, RS-232, and two USB host ports. A separate network interface accepts optional communication modules for additional network connections.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModular field-replaceable logic module\u003c\/li\u003e\n\u003cli\u003eCompatible with separately ordered display modules\u003c\/li\u003e\n\u003cli\u003eSupports 700, 1000, 1250, and 1500 terminal configurations\u003c\/li\u003e\n\u003cli\u003eRuns FactoryTalk View Machine Edition HMI applications\u003c\/li\u003e\n\u003cli\u003eSupports FactoryTalk ViewPoint remote access\u003c\/li\u003e\n\u003cli\u003eNetwork interface for optional communication modules\u003c\/li\u003e\n\u003cli\u003eSecure Digital card storage support\u003c\/li\u003e\n\u003cli\u003eBattery-backed real-time clock\u003c\/li\u003e\n\u003cli\u003eCommunication and fault status indicators\u003c\/li\u003e\n\u003cli\u003eReset switch for terminal restart\u003c\/li\u003e\n\u003cli\u003eDefault switch for maintenance operations\u003c\/li\u003e\n\u003cli\u003eCompatible with the 1250 high-bright display module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachine-level HMI applications\u003c\/li\u003e\n\u003cli\u003eOperator monitoring and control\u003c\/li\u003e\n\u003cli\u003eProcess status visualization\u003c\/li\u003e\n\u003cli\u003eProduction equipment interfaces\u003c\/li\u003e\n\u003cli\u003ePanelView Plus 6 terminal repair\u003c\/li\u003e\n\u003cli\u003eExisting terminal component replacement\u003c\/li\u003e\n\u003cli\u003eHMI system configuration and upgrades\u003c\/li\u003e\n\u003cli\u003eRockwell Automation controller visualization\u003c\/li\u003e\n\u003cli\u003eRemote HMI monitoring through FactoryTalk ViewPoint\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eInformation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e2711P-RP8D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnique Product Identifier\u003c\/td\u003e\n\u003ctd\u003e2711P-RP8D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e612598876877\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Description\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus 6 700-1500 Logic Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeature Configuration\u003c\/td\u003e\n\u003ctd\u003eWindows CE 6.0, no extended feature options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEstimated Lead Time\u003c\/td\u003e\n\u003ctd\u003e11 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Warranty Duration\u003c\/td\u003e\n\u003ctd\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscontinued Date\u003c\/td\u003e\n\u003ctd\u003eSeptember 30, 2023\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Category\u003c\/td\u003e\n\u003ctd\u003eEngineering Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e2711P-RP8D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHMI Logic Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Terminal Range\u003c\/td\u003e\n\u003ctd\u003e700, 1000, 1250, and 1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Configuration\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certification\u003c\/td\u003e\n\u003ctd\u003eMarine certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eMemory and Software\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM\u003c\/td\u003e\n\u003ctd\u003e512 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonvolatile Memory\u003c\/td\u003e\n\u003ctd\u003e512 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree User Memory\u003c\/td\u003e\n\u003ctd\u003eApproximately 79 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating System\u003c\/td\u003e\n\u003ctd\u003eWindows CE 6.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHMI Runtime\u003c\/td\u003e\n\u003ctd\u003eFactoryTalk View Machine Edition runtime, version 6.0 or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote HMI Software\u003c\/td\u003e\n\u003ctd\u003eFactoryTalk ViewPoint, version 1.2 or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtended Features\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003ePower Requirements\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Type\u003c\/td\u003e\n\u003ctd\u003eIsolated DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18...32V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Terminal Power Consumption\u003c\/td\u003e\n\u003ctd\u003e70 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current at 24V DC\u003c\/td\u003e\n\u003ctd\u003e2.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse Polarity Protection\u003c\/td\u003e\n\u003ctd\u003eInternally protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eCommunication\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port\u003c\/td\u003e\n\u003ctd\u003e10\/100 BaseT, Auto MDI\/MDI-X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Function\u003c\/td\u003e\n\u003ctd\u003eController communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Port\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS-232 Functions\u003c\/td\u003e\n\u003ctd\u003eController communication, printing, and file transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Host Ports\u003c\/td\u003e\n\u003ctd\u003eTwo USB 2.0 high-speed Type A ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Module Interface\u003c\/td\u003e\n\u003ctd\u003eNetwork interface connector for an optional communication module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Network Support\u003c\/td\u003e\n\u003ctd\u003eDH+\/DH-485, ControlNet, or additional Ethernet through the appropriate communication module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eStorage and Hardware\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003eSecure Digital card slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported SD Cards\u003c\/td\u003e\n\u003ctd\u003e1784-SDx and 1784-SDHCx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal-Time Clock\u003c\/td\u003e\n\u003ctd\u003eBattery-backed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion\u003c\/td\u003e\n\u003ctd\u003eSingle PCI slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indication\u003c\/td\u003e\n\u003ctd\u003eCommunication and fault indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance Controls\u003c\/td\u003e\n\u003ctd\u003eReset switch and default switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Power Input\u003c\/td\u003e\n\u003ctd\u003eConnects the isolated 18...32V DC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port\u003c\/td\u003e\n\u003ctd\u003eProvides 10\/100 BaseT controller and network communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS-232 Port\u003c\/td\u003e\n\u003ctd\u003eSupports controller communication, printing, and file transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Host Port 1\u003c\/td\u003e\n\u003ctd\u003eConnects supported USB peripherals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Host Port 2\u003c\/td\u003e\n\u003ctd\u003eConnects supported USB peripherals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Module Interface\u003c\/td\u003e\n\u003ctd\u003eAccepts an optional network communication module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD Card Slot\u003c\/td\u003e\n\u003ctd\u003eAccepts supported Secure Digital storage cards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Module Connectors\u003c\/td\u003e\n\u003ctd\u003eConnect the logic module to the compatible display module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCI Slot\u003c\/td\u003e\n\u003ctd\u003eSupports the internal expansion arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth\/Ground Connection\u003c\/td\u003e\n\u003ctd\u003eProvides the required low-impedance earth connection through the terminal assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect terminal power before installing or replacing the logic module.\u003c\/li\u003e\n\u003cli\u003eDisconnect all power and communication cables before replacement.\u003c\/li\u003e\n\u003cli\u003eWear an approved grounding wrist strap when handling the module.\u003c\/li\u003e\n\u003cli\u003eUse a static-safe workstation when available.\u003c\/li\u003e\n\u003cli\u003eDo not touch connectors, pins, or internal circuit components.\u003c\/li\u003e\n\u003cli\u003ePlace the display module face-down on a clean, flat, stable surface.\u003c\/li\u003e\n\u003cli\u003eAlign the logic module connectors with the display module connectors.\u003c\/li\u003e\n\u003cli\u003ePush the module down until it is firmly seated.\u003c\/li\u003e\n\u003cli\u003eTighten the four captive screws to 0.58 N.m (5...7 lb.in).\u003c\/li\u003e\n\u003cli\u003eRemove an installed communication module before replacing the logic module.\u003c\/li\u003e\n\u003cli\u003eAttach the logic module before installing an optional communication module.\u003c\/li\u003e\n\u003cli\u003eDo not connect or disconnect communication cables while power is applied.\u003c\/li\u003e\n\u003cli\u003eUse a dedicated 24V DC SELV or PELV power supply where required.\u003c\/li\u003e\n\u003cli\u003eConnect the terminal assembly to a low-impedance earth ground.\u003c\/li\u003e\n\u003cli\u003eDo not connect DC+ or DC- to the earth terminal.\u003c\/li\u003e\n\u003cli\u003eStore unused modules in static-safe packaging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003cth\u003eStatus\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certification\u003c\/td\u003e\n\u003ctd\u003eMarine certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695187161451,"sku":"2711P-RP8D","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-2711p-rp8d-logic-module-jkvz0oncmrt_f536a053-568f-4a8e-bbeb-f3e9e70a40eb.jpg?v=1766114498","url":"https:\/\/www.plcprotech.com\/products\/allen-bradley-2711p-rp8d-panelview-plus-6-700-1500-logic-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}