{"product_id":"allen-bradley-ek-2110-30-05-1-10-2100-series-non-contact-eddy-current-probe","title":"Allen-Bradley EK-2110-30-05-1-10 2100 Series Non-contact Eddy Current Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley EK-2110-30-05-1-10\u003c\/strong\u003e is an 8 mm (0.31 in.) tip diameter reverse mount non-contact pick-up probe belonging to the \u003cstrong\u003e2100 Series Eddy Current Probe Systems\u003c\/strong\u003e. This probe introduces eddy currents into a target material to read relative position by measuring energy loss changes as the target surface moves, supplying a modulated voltage output proportional to the gap between the probe tip and the target. Designed for non-contact measurement in speed and acceleration monitoring applications, the device features an M10x1 threaded body with a 30 mm (1.18 in.) body length and 5 mm (0.20 in.) unthreaded length, equipped with a 1.0 m (3.28 ft) standard Teflon-insulated sensor cable and a stainless steel, gold-plated SMA connector. Operating within a 2100 series system, the probe connects through an extension cable to a case-isolated, panel-mounted driver that conditions the radio frequency signal and maintains linearity over its operating range.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReverse Mount Configuration:\u003c\/strong\u003e Features reverse mount housing with an M10x1 body thread and a 30 mm (1.18 in.) body length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 mm Probe Tip:\u003c\/strong\u003e Engineered with an 8 mm (0.31 in.) tip diameter, suitable for speed and acceleration applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Cable:\u003c\/strong\u003e Integrated with a 1.0 m (3.28 ft) standard unarmored Teflon-insulated coaxial cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGold-Plated Connector:\u003c\/strong\u003e Terminated with a gold-plated stainless steel SMA connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Temperature Resistance:\u003c\/strong\u003e Rated for probe sensor operation across a temperature range of -40 to 177 degC (-40 to 350 degF).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachinery speed and acceleration measurement\u003c\/li\u003e\n\u003cli\u003eNon-contact shaft relative position sensing\u003c\/li\u003e\n\u003cli\u003e2100 Series eddy current proximity transducer measurement systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEK-2110-30-05-1-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2100 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-contact Eddy Current Pick-up Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReverse Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 mm (0.31 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM10x1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mm (1.18 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 mm (0.20 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Cable (Unarmored Teflon)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 m (3.28 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range (Approx.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 to 188 mils (0.2 to 4.7 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil (787 mV\/100 µm) (at 25 degC with -24V DC supply, 10 kΩ load, AISI 4140 steel target)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinearity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.8 mils of 200 mV\/mil (if calibrated as a system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC to 10 kHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless steel, gold-plated SMA connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Tip Diameter (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.5 mm (0.37 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 177 degC (-40 to 350 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 to 95% RH (noncondensing, nonsubmerged)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e Connect the probe via a matching 2100 series extension cable to a panel-mounted 2100 series driver; note that 2100 series drivers are not case-isolated and require an isolating pad or mounting inside an isolated enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDriver Power Supply:\u003c\/strong\u003e System operates with a driver supply voltage range of -17.5 to -26V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Wiring:\u003c\/strong\u003e Use 0.82 to 2.08 mm² (18 to 14 AWG) shielded 3-conductor instrumentation wire to connect the driver to the monitoring system. Limit total field cable distance to 300 m (984 ft) to ensure 0 to 10 kHz frequency response transmission with minimal attenuation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Ensure the cable shield is grounded at a single point, typically at the monitoring instrument.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e System Ex ia IIC T4, AEx ia IIC T4, Class I Zone 0\/1 or Class I Division 1; Groups A, B, C, D (when installed with safety barriers per drawing ETK51271-HAZ, sheet 1); Class I Division 2 Groups A, B, C, D without barriers per ETK51270-HAZ.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Union EMC Directive 2004\/108\/EC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC-Tick:\u003c\/strong\u003e Australian Radio Communications Act, compliant with AS\/NZS 2064 Industrial Emissions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e European Union ATEX Directive 94\/9\/EC II 1 G, Ex ia IIC T4 (EC certificate LCIE 07 ATEX 6051 X).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAPI Standard:\u003c\/strong\u003e API 670 compliant in all respects except for tolerance to environments containing hydrogen sulfide and ammonia.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53686545645931,"sku":"EK-2110-30-05-1-10","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/EK-2110-30-05-1-10_1200x1200_98047a15-ffd0-4cd1-8053-503602c520ff.jpg?v=1786193120","url":"https:\/\/www.plcprotech.com\/products\/allen-bradley-ek-2110-30-05-1-10-2100-series-non-contact-eddy-current-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}