{"product_id":"alr121-s51-s1-yokogawa-centum-vp-serial-communication-module","title":"ALR121-S51 S1 Yokogawa CENTUM VP Serial Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eALR121-S51 S1 \u003c\/strong\u003eis a high-reliability, 2-port serial communication module designed for the CENTUM VP Distributed Control System (DCS). Operating as a key data exchange bridge, this module is widely used in refineries, power stations, and chemical processing facilities to integrate subsystems—such as PLCs, safety systems, and analytical instruments—directly into the Field Control Station (FCS). By supporting both point-to-point RS-422 (4-wire) and multipoint RS-485 serial communication protocols, the module allows seamless connection to Modbus, MELSEC, or Allen-Bradley SLC500 subsystems. Featuring an ISA Standard G3 corrosion protection coating, this Style 1 module ensures continuous, uninterrupted process monitoring. This high-availability data link actively prevents signal blackouts and eliminates communication bottlenecks, directly protecting critical operational runtimes and reducing unplanned plant downtime.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe system ordering code for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eALR121-S51 S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule defines its hardware durability, environmental protections, and production style revision:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eALR121\u003c\/strong\u003e: Base model designator for the 2-Port Serial Communication Module (RS-422\/RS-485).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-S\u003c\/strong\u003e: Standard type module designed for standard industrial networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e5\u003c\/strong\u003e: Configured with no specialized explosion protection (suitable for standard control room or purged rack installations).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1\u003c\/strong\u003e: Equipped with ISA Standard G3 conformal coating for superior protection against corrosive gases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eS1\u003c\/strong\u003e: Style 1 design revision, indicating the physical hardware build standard for FIO slot compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertified Specification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eALR121-S51 S1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePorts\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 ports (RS-422 or RS-485 4-wire system)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterface Speed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1200 \/ 2400 \/ 4800 \/ 9600 \/ 19200 \/ 38400 bps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection Topologies\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePoint-to-point (RS-422); Multipoint (RS-485)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHalf-duplex\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSynchronizing Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStart-stop synchronization\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData Word Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000 words per module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Definitions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 128 definitions per module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Transmission Distance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1200 m (total extended cable length)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Current Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 A at 5 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Wiring Interfaces\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCable with 3-pair shield, AKB161, or AKB162 cables\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.30 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the two ports on the ALR121-S51 S1 run different communication protocols simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. A single communication module selects only one communication function at a time. Both port 1 and port 2 must be configured with identical communication functions (for example, both ports running Modbus RTU). You cannot configure port 1 for Modbus and port 2 for MELSEC-A on the same module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the ALR121-S51 S1 compatible with dual-redundant communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Dual-redundant communication is fully supported when utilizing FA-M3, Modbus, or MELSEC-A communication functions. This requires installing a matched pair of ALR121 modules in adjacent slots of a compatible FCS node unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the significance of the \"Lag time after data transmission\" parameter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 1 ms lag time is the mandatory hardware delay the module enforces to transition from transmitter mode to receiver mode. This precise delay prevents transceiver signal collision, ensuring that the module only begins scanning for incoming subsystem data after its own transmission is completely clear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding and Cable Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways use a high-quality 3-pair shielded cable (such as Yokogawa AKB161 or AKB162) for serial links. Connect the overall cable shield to the cabinet frame ground at the FCS end only. Keep the shield isolated at the field device end to prevent hazardous ground loops from introducing noise onto the RS-422\/RS-485 communication line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Block Connection Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure the field wires directly to the module's 5-poles-by-2 terminal block using M4 ring terminal lugs. Tighten the terminal screws to the recommended standard torque to prevent loose connections in high-vibration control environments, which can cause intermittent CRC errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLine Termination Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor long-distance RS-485 multipoint networks (approaching the 1200 m maximum), always install a 120 Ohm terminating resistor across the RX+ and RX- terminal lines at the physically last device on the bus. This prevents signal reflections from distorting the start-stop data bits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52695400972651,"sku":"ALR121-S51 S1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/yokogawa-alr121-s51-s1-communication-module-gf105nqv5uu_ba1ddeac-00ea-4e03-b5ec-7a331d3bedb7.jpg?v=1766133734","url":"https:\/\/www.plcprotech.com\/products\/alr121-s51-s1-yokogawa-centum-vp-serial-communication-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}