{"product_id":"b-r-0cfcrd-2048e-02-industrial-slc-compact-flash-2gb-card","title":"B\u0026R 0CFCRD.2048E.02 Industrial SLC Compact Flash 2GB Card","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0CFCRD.2048E.02 (0CFCRD2048E02)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a professional-grade storage solution specifically engineered for the high-availability demands of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eB\u0026amp;R Industrial PCs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAutomation Panel\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems. Unlike standard consumer-grade storage, this\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2048 MB (2 GB)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompact Flash card utilizes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSLC (Single-Level Cell)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eflash technology. This architecture is the gold standard for industrial automation, providing the extreme write endurance and thermal stability required for logging critical process data, hosting real-time operating systems (RTOS), and maintaining system integrity in \"lights-out\" manufacturing environments. With an extended temperature range from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-40 to 85 deg C\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0CFCRD.2048E.02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures deterministic performance where standard storage media would fail.\u003c\/p\u003e\n\u003ch3\u003eStorage Architecture and Data Integrity\u003c\/h3\u003e\n\u003cp\u003eThe core value of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0CFCRD.2048E.02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elies in its internal flash management and hardware-level reliability features, designed to prevent data corruption during power loss or high-frequency write operations.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSLC Flash Advantage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOffers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100,000 guaranteed erase\/write cycles\u003c\/strong\u003e, providing up to 10x the lifespan of MLC and 30x that of TLC alternatives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Wear Leveling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eImplements global, dynamic, and static algorithms to ensure every memory cell is utilized evenly, preventing premature \"hot spot\" failure in frequently updated log files.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Bus Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCapable of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUDMA6 \/ MDMA4 \/ PIO6\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodes, delivering a continuous reading speed of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32.2 MB\/s\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand writing speed of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e19.9 MB\/s\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor rapid system boot-up and data buffering.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eError Correction \u0026amp; Health Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eECC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS.M.A.R.T. support\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallow for proactive maintenance, enabling the PLC or IPC to flag the card for replacement before it reaches its end-of-service life.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; height: 235.126px;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\" style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8912%; height: 19.5938px;\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.2516%; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8912%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.2516%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003e0CFCRD.2048E.02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8912%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.2516%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8912%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.2516%; height: 19.5938px;\"\u003e\u003cspan\u003e2048 MB (2 GB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8912%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eMemory Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.2516%; height: 19.5938px;\"\u003e\u003cspan\u003eSLC (Single-Level Cell)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8912%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eErase\/Write Cycles\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.2516%; height: 19.5938px;\"\u003e\u003cspan\u003e100,000 cycles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8912%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eData Retention\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.2516%; height: 19.5938px;\"\u003e\u003cspan\u003e10 years (when new)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8912%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.2516%; height: 19.5938px;\"\u003e\u003cspan\u003e-40 to 85 deg C (Industrial Grade)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8912%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.2516%; height: 19.5938px;\"\u003e\u003cspan\u003e1500 g peak\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8912%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.2516%; height: 19.5938px;\"\u003e\u003cspan\u003e20 g peak (10 to 2000 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8912%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.2516%; height: 19.5938px;\"\u003e\u003cspan\u003eCE, UKCA, UL, DNV (Marine), ABS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8912%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.2516%; height: 19.5938px;\"\u003e\u003cspan\u003e1.0 kg (including protective packaging)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is SLC memory critical for my B\u0026amp;R Automation Studio project?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIndustrial controllers frequently perform small, repetitive write operations (cycle counters, alarm logs, and recipe changes).\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSLC (Single-Level Cell)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ememory is required because it stores only 1 bit per cell, resulting in significantly lower bit-error rates and the ability to withstand these high-frequency writes for decades, whereas consumer cards often fail within months.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this Compact Flash card suitable for maritime or offshore use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0CFCRD.2048E.02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eholds\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDNV (Det Norske Veritas)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecertifications. It is tested for Temperature Class B, Humidity Class B, and Vibration Class B (4 g), making it compliant for installation on ships’ bridges and open deck equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if I use a standard 2 GB CF card instead of this industrial version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA consumer card lacks the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eECC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGlobal Wear Leveling\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enecessary for industrial file systems. Using a non-industrial card increases the risk of \"Read-Only\" lockouts, file system corruption during a sudden power loss, and unpredictable system crashes that can lead to expensive production downtime.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHandling Precautions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEven though the card is rated for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1500 g shock\u003c\/strong\u003e, the internal controller is sensitive to Static Discharge (ESD). Always use an ESD wrist strap when inserting or removing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0CFCRD.2048E.02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom the IPC slot.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Formatting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor maximum reliability, only format the card using the utilities provided within\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eB\u0026amp;R Automation Studio\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor the target hardware's BIOS. Avoid formatting via standard Windows Disk Management unless specified, as this can affect the alignment of the wear-leveling clusters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHealth Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLeverage the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS.M.A.R.T.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edata. In your B\u0026amp;R PLC logic, you can monitor the \"Remaining Life\" registers of the card to trigger a preventative maintenance alarm on the HMI when the card's endurance reaches 10% remaining.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0CFCRD.2048E.02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis more than a storage device; it is a critical system component. With its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10-year data retention\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegration capability, it provides the peace of mind required for remote installations where physical access is limited. Its certification for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHazardous Locations (cULus E115267)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand Marine environments ensures it can be deployed in the most aggressive atmospheres, from engine rooms to chemical refineries, without compromising the integrity of the mission-critical software it hosts.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086378983787,"sku":"0CFCRD.2048E.02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/0cfcrd2048e02-trcbofn1jik.png?v=1776064682","url":"https:\/\/www.plcprotech.com\/products\/b-r-0cfcrd-2048e-02-industrial-slc-compact-flash-2gb-card","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}