{"product_id":"b-r-3dm476-6-system-2005-digital-mixed-i-o-module-1","title":"B\u0026R 3DM476.6 System 2005 Digital Mixed I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3DM476.6 (3DM4766)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density digital mixed module from the B\u0026amp;R System 2005 series, engineered to provide versatile interfacing for both 24 VDC and 24 VAC signal environments. Featuring 16 digital inputs and a high-current output stage rated at 0.4 A per channel, this module is an ideal solution for mid-to-large scale automation tasks requiring a hybrid of sensing and actuation in a single slot. Its ability to handle AC\/DC voltages makes it particularly valuable for legacy plant upgrades and complex machinery where different control voltages coexist. Built to an IP20 protection standard, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3DM476.6\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures stable performance in centralized control cabinets for applications ranging from industrial HVAC systems to automated assembly lines.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3DM476.6\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is designed with robust electrical isolation to protect the central processing unit and maintain signal integrity. While there is no channel-to-channel isolation, the module features comprehensive group isolation between input groups and output groups. Power management is split between an internal 2.5 W consumption at 5 VDC (logic side) and an external 24 V supply consuming 2.0 W. The output stage is specifically rated for 0.4 A, providing sufficient power to drive industrial solenoids, contactors, and signaling lamps directly. Its mechanical design follows the System 2005 standard, ensuring a secure fit and reliable backplane communication within the rack.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3DM476.6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem 2005\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Mixed I\/O Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC \/ 24 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.4 A per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Power Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 W at 5 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Power Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 W at 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGroup Isolation (Input-Input \/ Input-Output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 3DM476.6 support independent isolation for each channel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the module utilizes group isolation. This means while the input groups are isolated from each other and the output groups, individual channels within the same group share a common reference point. This design optimizes space while providing sufficient protection against high-voltage surges between different functional sections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module to switch both DC and AC loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe inputs are rated for both 24 VDC and 24 VAC signals, providing excellent flexibility for field sensors. However, always verify that the output load does not exceed the 0.4 A rating per channel to prevent thermal stress on the output drivers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power supplies are required for this module to operate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module requires two power sources: the internal 5 VDC supplied by the System 2005 backplane for logic operations and an external 24 V supply for the I\/O circuits and actuator power.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management in High-Load Scenarios:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen driving multiple outputs at the 0.4 A limit simultaneously, the total power dissipation can increase. Ensure the control cabinet has adequate ventilation. If the module is mounted in an area with restricted airflow, consider de-rating the output current or leaving a small gap between high-power modules to prevent localized overheating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Isolation Practices:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBecause the module lacks channel-to-channel isolation, ensure that all sensors connected to a single input group share a compatible ground or common potential. Mixing incompatible power sources within a single isolated group can lead to ground loops or equipment damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Seating and Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor System 2005 modules, ensure the module is fully inserted and the retaining screws are properly engaged. The module relies on the rack's grounding system for EMI shielding; ensure the DIN rail or rack frame is bonded to the main functional earth of the machine.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53102125711723,"sku":"3DM476.6","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3dm476.6-ex5fzonuaox.png?v=1776137118","url":"https:\/\/www.plcprotech.com\/products\/b-r-3dm476-6-system-2005-digital-mixed-i-o-module-1","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}