{"product_id":"b-r-8bvi0028hcd0-000-1-acoposmulti-2-axis-inverter-module","title":"B\u0026R 8BVI0028HCD0.000-1 ACOPOSmulti 2-Axis Inverter Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8BVI0028HCD0.000-1 (8BVI0028HCD0.000-1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density 2-axis inverter module developed for the modular ACOPOSmulti drive platform, engineered specifically for cold plate or feed-through mounting environments. By housing two fully independent power inverter stages within a single physical enclosure, this module maximizes power density for multi-axis synchronization in demanding applications such as high-speed robotic assembly, precision packaging arrays, and complex textile machinery. The unit utilizes the modular ACOPOSmulti backplane to integrate directly into the DC bus architecture, facilitating efficient regenerative energy sharing and optimal thermal management in space-constrained industrial control cabinets.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThis module provides advanced power control through high-speed switching and integrated logic monitoring, suitable for high-demand motion control sequences requiring functional safety.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe cold plate or feed-through design allows for direct mounting to liquid-cooled heat sinks or external cabinet surfaces, drastically improving heat dissipation compared to standard air-cooled modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith two independent inverter stages, the module supports complex multi-axis motion, while the \"AS\" (Advanced Safety) configuration provides integrated, dual-channel functional safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt features a robust input capacitance of 23.5 microfarads to mitigate voltage ripple, while the internal logic is powered by a stable 25 VDC input feed, ensuring consistent control signal integrity during high-load transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Expansion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with 2 dedicated slots for plug-in modules, allowing for customized fieldbus, feedback, or technology function integration without increasing the physical footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8BVI0028HCD0.000-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eACOPOSmulti 2-Axis Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCold plate or feed-through\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAxis Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Independent Inverters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.8 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLogic Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 VDC +\/- 1.6%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Capacitance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e23.5 microfarads\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePlug-in Slots\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDischarge Capacitance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 microfarads\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Hardware Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 2.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Hardware FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the functional benefit of the \"cold plate or feed-through\" mounting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis mounting method is intended for high-density cabinets or environments with high ambient temperatures where natural air convection is insufficient. By transferring heat directly to a liquid circuit or outside the cabinet enclosure, you can achieve higher current density and extended hardware service life, protecting internal components from heat-related premature failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the integrated \"AS\" designation impact machine safety?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"AS\" designation denotes Advanced Safety capabilities. This allows the drive to execute safety functions like Safe Torque Off (STO) directly on the drive level, eliminating the need for external safety contactors and reducing the complexity of hard-wired safety logic while maintaining SIL 3 \/ PL e compliance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the 2 slots for plug-in modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese slots offer scalability. Depending on your machine requirements, you can insert specific modules to handle different encoder feedback types (like EnDat 2.2 or SSI) or additional communication interfaces, allowing the base inverter to adapt to various automation requirements without replacing the entire drive unit.\u003c\/p\u003e\n\u003ch3\u003eField Commissioning and Safety Guidelines\u003c\/h3\u003e\n\u003ch3\u003eThermal Interface Preparation\u003c\/h3\u003e\n\u003cp\u003eWhen utilizing cold plate mounting, ensure the mating surface of the heat sink is perfectly flat and free of debris. Apply a high-thermal-conductivity interface material (TIM) or thermal grease to ensure maximum heat transfer. Tighten all mounting fasteners to the torque specifications provided in the B\u0026amp;R installation manual to prevent air gaps that could cause local hotspots.\u003c\/p\u003e\n\u003ch3\u003eDC Bus Connectivity and Torque\u003c\/h3\u003e\n\u003cp\u003eThe shared DC bus connection is critical for multi-axis performance. Use the factory-specified bus connectors and ensure all bolts are torqued to the correct Nm rating. Loose connections here will lead to increased impedance, voltage drops, and potential DC bus error trips during high-acceleration phases.\u003c\/p\u003e\n\u003ch3\u003eMaintenance of Feed-Through Seals\u003c\/h3\u003e\n\u003cp\u003eIf using feed-through mounting to isolate the power section from the control section (for instance, to pass heat through a cabinet wall), ensure the gasket seals remain intact and airtight. Compromised seals allow conductive dust or moisture into the drive’s internal electronics, which can lead to short circuits or premature module failure.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086369644907,"sku":"8BVI0028HCD0.000-1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8bvi0028hcd0.000-1-ykbjtmf2144.png?v=1776137179","url":"https:\/\/www.plcprotech.com\/products\/b-r-8bvi0028hcd0-000-1-acoposmulti-2-axis-inverter-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}