{"product_id":"b-r-8bvi0055hwd0-000-1-acoposmulti-inverter-module","title":"B\u0026R 8BVI0055HWD0.000-1 ACOPOSmulti Inverter Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8BVI0055HWD0.000-1 (8BVI0055HWD0.0001)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision inverter module belonging to the B\u0026amp;R ACOPOSmulti series, designed for advanced motion control and energy-efficient drive solutions. This unit is engineered to manage power conversion within multi-axis drive systems, commonly deployed in high-speed packaging, CNC machining, and automated assembly lines. By utilizing the ACOPOSmulti platform, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8BVI0055HWD0.000-1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtributes to a reduced cabinet footprint and optimized power distribution via a common DC bus. Its robust design ensures stable operation in demanding industrial sectors such as textile manufacturing and metal processing, where precise torque and speed control are critical to maintaining production uptime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eAs an integral component of the ACOPOSmulti ecosystem, this inverter drive is characterized by its modular hardware architecture and high-voltage DC bus compatibility.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDC Bus Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for operation within a shared DC bus environment, supporting voltages up to 900 VDC to maximize energy recovery and distribution between motoring and braking axes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Control Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperates on a stabilized 25 VDC input voltage (plus or minus 1.6%) for internal logic and control circuits, ensuring immunity against fluctuations in the primary power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Circuit Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a low internal resistance (0.5 Ohm) and a defined extinction potential (approx. 30 V) to safeguard sensitive electronic components during rapid switching cycles or power-down sequences.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal and Environmental Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRated at IP20 (front side), the module is designed for installation in control cabinets with controlled ambient conditions, providing protection against solid foreign objects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8BVI0055HWD0.000-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R Industrial Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInverter Drive \/ Inverter Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax. DC Bus Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e900 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 VDC (plus or minus 1.6 percent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.1 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExtinction Potential\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 30 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 25 VDC input for this drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 8BVI0055HWD0.000-1 requires a specific 25 VDC supply for its internal electronics. This slightly higher-than-standard voltage (compared to 24 VDC) accounts for potential voltage drops across the backplane and ensures the drive logic remains active even during heavy load transients on the DC bus.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be used in a standalone configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the ACOPOSmulti inverter modules are designed to be part of a larger drive system. They must be mounted on the appropriate backplane and connected to a common DC bus supplied by a power supply module (8BVP series).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the cooling handled for this specific inverter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 4.5 kg weight reflects a substantial heat sink and internal thermal management system. Depending on the backplane configuration, cooling is typically achieved through forced air within the cabinet or cold-plate mounting.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Guidelines and Safety Protocols\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDC Bus Safety Discharge:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWARNING: High voltage (up to 900 VDC) may remain present on the DC bus terminals long after the main power is disconnected. Always use a calibrated multimeter to verify that the DC bus voltage has dropped below 50 V before performing any wiring or maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Alignment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installing the module into the ACOPOSmulti rack, ensure that the power and signal connectors are perfectly aligned before applying pressure. Misalignment can damage the high-current DC bus contacts, leading to arcing and localized overheating during operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo minimize electromagnetic interference (EMI), ensure that motor cables are properly shielded and that the shield is clamped to the grounding plate at the bottom of the drive. Maintain separation between high-voltage DC bus cables and low-voltage communication lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTightening Torque:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAll power terminals must be tightened to the manufacturer's specified torque settings. Loose connections on the DC bus or motor phases can result in catastrophic failure of the inverter bridge due to contact resistance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086376526187,"sku":"8BVI0055HWD0.000-1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8bvi0055hwd0000-1-cfzcglujy12.png?v=1776137181","url":"https:\/\/www.plcprotech.com\/products\/b-r-8bvi0055hwd0-000-1-acoposmulti-inverter-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}