{"product_id":"b-r-8bvr0440h000-100-2-acoposmulti-regeneration-choke","title":"B\u0026R 8BVR0440H000.100-2 ACOPOSmulti Regeneration Choke","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8BVR0440H000.100-2 (8BVR0440H0001002)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-capacity industrial regeneration choke specifically engineered for the B\u0026amp;R ACOPOSmulti drive system. This critical electromagnetic component is designed to work in conjunction with active power supply modules to facilitate the return of regenerative braking energy back to the mains supply. By filtering and smoothing current during energy recovery, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8BVR0440H000.100-2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eminimizes harmonic distortion and enhances the overall energy efficiency of multi-axis motion control systems. It is an essential element for high-inertia applications such as heavy-duty centrifuges, elevators, and large-scale printing presses where frequent deceleration phases would otherwise result in wasted thermal energy.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThis regeneration choke is optimized for high-power throughput and robust thermal management within industrial power grids.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Current Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports a continuous current of 45 A, making it suitable for demanding motor loads and high-torque applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWide Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for three-phase systems ranging from 220 VAC to 480 VAC (plus or minus 10 percent), providing global compatibility for various industrial power standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eACOPOSmulti Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically tuned to the switching frequencies of the ACOPOSmulti series, ensuring maximum electromagnetic compatibility (EMC) and reducing stress on the DC bus capacitors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Terminal Blocks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures heavy-duty terminal blocks for secure, vibration-resistant electrical connections capable of handling the 17 kg mass of the inductive core.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8BVR0440H000.100-2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R Industrial Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMains Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3x 220 to 3x 480 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 \/ 60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 to 40 deg C (up to 55 deg C with derating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 17 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the 8BVR0440H000.100-2?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis choke is used during regenerative braking. When a motor decelerates, it acts as a generator. The choke filters this generated energy so it can be safely and efficiently fed back into the power grid instead of being dissipated as heat through a braking resistor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this choke be mounted in any orientation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDue to its significant weight (17 kg) and the need for convective cooling, the choke should be mounted according to the manufacturer's specified orientation (typically vertical) to ensure heat is effectively dissipated from the windings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this component compatible with third-party drives?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the electrical characteristics (inductance and saturation levels) of the 8BVR0440H000.100-2 are specifically matched to the B\u0026amp;R ACOPOSmulti active power supply modules. Use with non-B\u0026amp;R hardware may lead to inefficient energy recovery or damage to the power electronics.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Installation and Thermal Management\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 17 kg weight of the unit requires a reinforced mounting plate within the control cabinet. Use all provided mounting holes and ensure the cabinet structure can support the static load and any dynamic forces caused by industrial vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRegeneration chokes generate significant heat during heavy braking cycles. Maintain the minimum specified clearance distances (top and bottom) to ensure unobstructed airflow. If the ambient temperature exceeds 40 deg C, forced ventilation or a reduction in duty cycle may be required to prevent thermal cutout.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Standards:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse high-temperature rated industrial cabling for the connections to the 45 A terminal blocks. Ensure all connections are torqued to the official B\u0026amp;R specifications to prevent contact resistance, which can lead to localized overheating and fire hazards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMC Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo minimize interference with sensitive control signals, keep the power leads between the regeneration choke and the power supply module as short as possible. Use shielded cables where necessary and ensure a low-impedance ground connection to the mounting plate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086376231275,"sku":"8BVR0440H000.100-2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8bvr0440h000.100-2-a2sa0ob4oxb.png?v=1776137186","url":"https:\/\/www.plcprotech.com\/products\/b-r-8bvr0440h000-100-2-acoposmulti-regeneration-choke","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}