{"product_id":"b-r-x20ao2622-analog-output-module-2-channel","title":"B\u0026R X20AO2622 Analog Output Module 2-Channel","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20AO2622 (X20 AO 2622)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision 2-channel analog output module within the B\u0026amp;R X20 System, engineered for versatile signal interfacing in complex industrial automation architectures. This module provides the capability to drive both voltage (\u003cspan class=\"math-inline\"\u003e$\\pm10$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eV) and current (\u003cspan class=\"math-inline\"\u003e$0$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eto\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$20$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003emA \/\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$4$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eto\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$20$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003emA) signals, allowing engineers to interface with a wide variety of actuators, such as proportional valves, frequency inverters, and process controllers. With its\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$13$\u003c\/span\u003e-bit resolution and integrated electrical isolation between the channel and the bus, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20AO2622\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures signal integrity and noise immunity in harsh electrical environments common in chemical processing, water treatment, and motion control applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe module architecture is designed for flexibility and rapid signal processing, utilizing a software-configurable setup for channel types.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Signal Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsers can switch between voltage and current outputs simply by utilizing different terminal connections, eliminating the need for separate hardware modules for different signal types.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Conversion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a conversion time of\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$200$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\mu$\u003c\/span\u003es for all outputs, paired with a first-order low-pass filter (cutoff frequency\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$10$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ekHz) to provide smooth, stable analog signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe outputs are short-circuit proof with current limiting up to\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\pm40$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003emA, and the module incorporates an internal enable relay to manage startup behavior and prevent erratic signals during system power-up.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$500$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$V_{eff}$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eelectrical isolation between the output channels and the internal system bus, protecting the backplane from field-side transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20AO2622\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R Industrial Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eID Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0x1BA2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Analog (Voltage or Current)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e$\\pm10$\u003c\/span\u003e V, \u003cspan class=\"math-inline\"\u003e$0$\u003c\/span\u003e to \u003cspan class=\"math-inline\"\u003e$20$\u003c\/span\u003e mA, \u003cspan class=\"math-inline\"\u003e$4$\u003c\/span\u003e to \u003cspan class=\"math-inline\"\u003e$20$\u003c\/span\u003e mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13-bit (including sign)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConversion Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 \u003cspan class=\"math-inline\"\u003e$\\mu$\u003c\/span\u003es\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLoad Resistance (Voltage)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e$\\ge 1$\u003c\/span\u003e k$\\Omega$\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLoad Resistance (Current)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax. \u003cspan class=\"math-inline\"\u003e$600$\u003c\/span\u003e \u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e (Rev. \u003cspan class=\"math-inline\"\u003e$\\ge$\u003c\/span\u003e J0)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp (Horizontal)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation (Internal)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.1 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I select between voltage and current output on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe selection is handled through physical wiring to specific terminals on the X20 terminal block. Software configuration is also required to set the channel type and range (\u003cspan class=\"math-inline\"\u003e$\\pm10$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eV,\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$4-20$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003emA, etc.) to match the physical connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat terminal blocks and bus modules are compatible with this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe X20AO2622 is designed for use with the X20TB06 (6-pin) or X20TB12 (12-pin) terminal blocks. It must be mounted on an X20BM11 bus module to interface with the X20 system backplane. These must be ordered separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the resolution differ between voltage and current modes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe digital converter resolution is\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$13$\u003c\/span\u003e-bit including the sign. Specifically, for voltage, it is\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\pm12$\u003c\/span\u003e-bit (\u003cspan class=\"math-inline\"\u003e$1$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eLSB =\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$2.441$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003emV). For current, it is\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$12$\u003c\/span\u003e-bit (\u003cspan class=\"math-inline\"\u003e$1$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eLSB =\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$4.883$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\mu$\u003c\/span\u003eA).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Guidelines and Environmental Considerations\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Block Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that signals are connected to the correct terminals according to the B\u0026amp;R wiring diagram. Using the wrong terminal for a current loop when configured for voltage (or vice versa) may prevent signal output or trigger a module error.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Derating at Elevation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor installations exceeding\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$2000$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003emeters above sea level, the maximum ambient operating temperature must be reduced by\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$0.5$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003edeg C per every\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$100$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003emeters of additional elevation to ensure adequate heat dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStartup Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal enable relay ensures the outputs remain in a safe state during the module's boot-up phase. Verify that the \"Module Run\" LED is steady green before relying on the analog output signal for critical process control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFilter Characteristics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$10$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ekHz low-pass filter is sufficient for most industrial applications; however, for high-speed motion loops, the\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$1$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ems settling time must be factored into the controller's PID loop tuning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086376427883,"sku":"X20AO2622","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20ao2622-g2vnqrmmp0k.png?v=1776138126","url":"https:\/\/www.plcprotech.com\/products\/b-r-x20ao2622-analog-output-module-2-channel","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}