{"product_id":"b-r-x20if10e1-1-x20-communication-interface-module","title":"B\u0026R X20IF10E1-1 X20 Communication Interface Module","description":"\u003ch3\u003eSystem Functional Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eB\u0026amp;R X20IF10E1-1 (X20IF10E1-1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance PROFINET IO controller interface module designed for seamless integration within the standard B\u0026amp;R X20 system architecture. Deployed globally across complex industrial applications such as automotive assembly lines, high-speed packaging networks, and municipal water treatment facilities, this module establishes deterministic real-time Ethernet master connectivity. By offloading fieldbus processing from the primary CPU, it minimizes loop cycle times and guarantees rapid data throughput, significantly minimizing system latency and avoiding costly operational bottlenecks in synchronized automation lines.\u003c\/p\u003e\n\u003ch3\u003eFieldbus Architecture and Transmission Dynamics\u003c\/h3\u003e\n\u003cp\u003eEngineered as a dedicated PROFINET IO master, this module features a dual-port shielded RJ45 variant with an integrated switch layout to facilitate flexible line or ring network topologies without requiring external industrial switches. The hardware supports standard transfer rates of 100 Mbit\/s over a maximum segment length of 100 m between stations. To protect delicate internal processing units from high-voltage transients on the factory floor, the interface module incorporates complete electrical isolation between the primary PLC backplane and the PROFINET IO channels (IF1 and IF2).\u003c\/p\u003e\n\u003ch3\u003eTechnical Performance Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCharacteristic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20IF10E1-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Automation Studio Architecture)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAustria\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROFINET IO Controller (Master)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2x Shielded RJ45 (Embedded Switch)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 Mbit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Segment Distance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 m between two stations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePLC logic fully isolated from IF1 and IF2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 deg C (Standard horizontal mounting)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 x 99 x 74 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.12 kg (Net) \/ 2.0 kg (Shipping gross)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the integrated switch on the X20IF10E1-1 support PROFINET Media Redundancy Protocol (MRP)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The dual-port shielded RJ45 switch configuration allows the module to operate within a ring topology governed by PROFINET MRP parameters. This setup ensures that if a single network cable breaks, communication recovers within milliseconds to maintain continuous plant operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat action should be taken if the module fails to establish a link with a slave node over a 90-meter run?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirst, check the integrity of the shielded RJ45 connections and ensure category Cat 5e or higher industrial Ethernet cabling is utilized. Ensure that the total run does not exceed the strict 100 m segment limitation, and verify that the cable shields are securely grounded on both ends to eliminate heavy electromagnetic noise.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs separate external power wiring required to achieve the 2 W power requirement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The X20IF10E1-1 draws its 2 W operating power directly from the X20 system internal backplane bus. However, system builders must calculate the total power budget of the rack to ensure that the primary X20 system power supply module possesses sufficient capacity.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Commissioning and Safety Directives\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Grounding Framework:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen landing communication cables into the dual RJ45 ports, always utilize fully shielded industrial RJ45 plugs with metal housings. The cable shield must make direct contact with the port housing. This arrangement maintains the electrical isolation boundary between the industrial network and the internal PLC logic rails, diverting transient spikes away from the processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Cable Routing Paths:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain physical separation between the PROFINET Ethernet lines and high-voltage AC power paths or variable frequency drive (VFD) output cables. Cross these cables at 90-degree angles rather than running them parallel to prevent magnetic field coupling from corrupting the 100 Mbit\/s data packets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Insertion and Backplane Alignment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the X20 base module is securely locked onto the DIN rail before sliding the X20IF10E1-1 electronics module into place. Inspect the backplane gold-plated bus connectors for debris prior to insertion to prevent high-resistance contacts that can lead to intermittent 2 W power supply dropouts or bus communication errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086373052779,"sku":"X20IF10E1-1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20if10e1-1-gzbc1ezhn0z.png?v=1776138209","url":"https:\/\/www.plcprotech.com\/products\/b-r-x20if10e1-1-x20-communication-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}