{"product_id":"b-r-x20pd2113-x20-series-digital-output-module","title":"B\u0026R X20PD2113 X20 Series Digital Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20PD2113 (X20PD2113)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision digital output module engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eB\u0026amp;R X20 System\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture. This module features 6 high-reliability outputs specifically designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSink (NPN)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnection configurations. Operating at a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignal supply, it is a critical component for controlling specialized actuators, solenoid valves, and indicator systems in automated production lines. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20PD2113\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis frequently deployed in high-speed sorting, semiconductor manufacturing, and precision assembly applications where efficient space utilization and robust electrical switching are paramount. By integrating this module into the X20 station, engineers gain a durable interface that reduces system complexity and ensures consistent performance in 24\/7 industrial operations.\u003c\/p\u003e\n\u003ch3\u003eHardware Logic and Interface Control\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20PD2113\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for high-performance switching in distributed I\/O topologies. Its internal circuitry is designed to manage thermal loads efficiently while maintaining rapid response times across all channels.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSink (NPN) Output Topology:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module switches the negative potential (0 V) to the load, making it the ideal interface for devices that require a ground-switching signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e6-Channel Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides a balanced density for localized control zones, allowing for granular output management without overcrowding the backplane bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandardized X20 Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFully compatible with the modular X20 \"slice\" design, supporting hot-pluggable functionality when used with the appropriate B\u0026amp;R bus base.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eX20PD2113\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSink (NPN)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to +70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 to 95% (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the \"Sink\" connection in the X20PD2113 differ from \"Source\" modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20PD2113\u003c\/strong\u003e, the output acts as a switch to ground. When the output is active, it completes the circuit for a load that is already connected to the positive 24 VDC rail. This is commonly used in NPN-standard environments and for specific high-speed switching circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the power supply requirements for the output stage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module requires a stable\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignal supply. It is recommended to use a regulated industrial power supply to ensure that voltage fluctuations do not affect the switching thresholds or the longevity of the internal optocouplers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix Sink and Source modules on the same X20 backplane?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The B\u0026amp;R X20 system backplane is designed for multi-protocol and multi-logic integration. You can install the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20PD2113\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ealongside sourcing modules, provided each module is wired according to its specific electrical requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring for Sink Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways verify that your field device is connected to the +24 VDC supply. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20PD2113\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal will receive the \"return\" wire from the load to pull it to ground. Incorrect wiring can lead to a \"short circuit to supply\" condition which may trip internal protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInductive Load Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen driving solenoids or relays, ensure that external suppression (flyback diodes) is used if the load does not have integrated protection. This prevents high-voltage spikes from damaging the NPN transistors during de-energization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Seating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the module is firmly clicked into the X20 bus base. An improperly seated module can cause intermittent \"I\/O Bus Fail\" errors in the PLC CPU. Check that the locking slide is fully engaged.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20PD2113\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estands out for its reliability in environments with high electromagnetic interference. By using a sink-based switching logic, it often provides better noise immunity for specific types of industrial sensors and actuators. The rugged\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1.5 kg\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eshipping build reflects the high-quality materials used in its housing and connectors, ensuring that the module can withstand the vibrations typical of CNC machinery and automated conveyor systems. Its native integration into B\u0026amp;R Automation Studio allows for rapid commissioning and real-time channel diagnostics.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086378918251,"sku":"X20PD2113","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20pd2113-hoxrgli3n50.png?v=1776064837","url":"https:\/\/www.plcprotech.com\/products\/b-r-x20pd2113-x20-series-digital-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}