{"product_id":"b-r-x20ps2100-x20-internal-i-o-power-supply-module","title":"B\u0026R X20PS2100 X20 Internal I\/O Power Supply Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20PS2100 (X20PS2100)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance power supply module engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eB\u0026amp;R X20 System\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebackplane. This module is specifically designed to provide the internal supply for the I\/O power bus, serving as the electrical foundation for downstream digital and analog modules. Operating on a nominal\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einput, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20PS2100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a wide tolerance range (\u003cstrong\u003e-15% \/ +20%\u003c\/strong\u003e), ensuring stable system performance even in industrial environments prone to voltage fluctuations. With integrated status indicators for real-time diagnostics, this module minimizes troubleshooting time and prevents costly system downtime by ensuring the I\/O bus remains powered within strict operational parameters.\u003c\/p\u003e\n\u003ch3\u003ePower Management and Diagnostic Logic\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20PS2100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the gateway between the external power source and the sensitive internal I\/O circuitry. Its architecture is focused on electrical stability and preventative monitoring.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal I\/O Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module feeds the internal supply lines of the X20 station, allowing a segment of I\/O modules to function without overloading the CPU's primary power capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVisual Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures front-facing status indicators for \"Operating State\" and \"Module Status,\" allowing field technicians to instantly verify power health without external meters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to handle an input range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20.4 VDC to 28.8 VDC\u003c\/strong\u003e, making it compatible with various global industrial power standards and battery-backed systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eX20PS2100\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (-15 % \/ +20 %)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRequired Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax. 10 A (Slow-blow fuse)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.5 mm Width (Standard X20 single-width)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 kg (including bulk protection\/packaging)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the X20PS2100 within an X20 station?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20PS2100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis used to \"refresh\" or initially supply the I\/O power bus. If the cumulative power consumption of your I\/O modules exceeds the capacity provided by the bus controller, this module is inserted to provide additional current to the segment to its right.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is a 10 A \"slow-blow\" fuse specified for the input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIndustrial power supplies often experience inrush current upon startup. A\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10 A slow-blow fuse\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprevents nuisance tripping during the initial charging of the module's internal capacitors while still providing robust short-circuit protection for the system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module provide power to the X2X Link (Communication) bus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20PS2100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis dedicated to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einternal I\/O supply\u003c\/strong\u003e. For powering the X2X Link communication bus, a specialized bus controller or a dedicated communication power supply module must be used.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePotential Grouping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20PS2100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto create independent potential groups. By placing this module in the middle of a rack, you can isolate the power supply of a specific group of modules (e.g., isolating sensitive analog inputs from noisy digital outputs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the input power cables are sized correctly for the 10 A capacity. Use high-quality ferrules to ensure a gas-tight connection at the terminal block, preventing resistive heating at the power entry point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Consideration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlthough the module is highly efficient, multiple power supply modules in a single rack can generate significant heat. Maintain the standard vertical orientation to allow for natural convection through the X20 housing vents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20PS2100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built for the rigors of heavy industry. Its wide input voltage tolerance makes it an ideal choice for mobile automation and maritime applications where engine-driven alternators can cause voltage swings. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5.0 kg\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eshipping weight (reflecting the robust protective packaging required for sensitive power electronics) ensures the module arrives in factory-calibrated condition. Native integration into\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eB\u0026amp;R Automation Studio\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for software-based monitoring of the module status, enabling proactive maintenance alerts before a power failure impacts the entire production line.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086378754411,"sku":"X20PS2100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/X20PS2100-sc3dzapyg1s.png?v=1776064839","url":"https:\/\/www.plcprotech.com\/products\/b-r-x20ps2100-x20-internal-i-o-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}