{"product_id":"beckhoff-c9900-e897-push-button-extension-for-cp6xxx-and-cp7xxx-control-panels-and-panel-pcs","title":"BECKHOFF C9900-E897 Push-Button Extension for CP6xxx and CP7xxx Control Panels and Panel PCs","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF C9900-E897\u003c\/strong\u003e is a push-button extension designed for CP6x23-00xx and CP7x23-00xx Control Panels and Panel PCs. It is installed on the right side of compatible 15-inch units without a keyboard.\u003c\/p\u003e\n\u003cp\u003eThe extension provides 20 Siemens Signum square push-button keys with integrated signal lamps. Each push-button measures 30 x 30 mm. Individual labels can be inserted into the push-button caps for application-specific identification.\u003c\/p\u003e\n\u003cp\u003eAll push-buttons provide one normally-open contact transmitted through USB. A second normally-open contact is available for direct wiring through a terminal row. The signal lamps are controlled exclusively through USB.\u003c\/p\u003e\n\u003cp\u003eThe assembly also includes one Siemens Signum emergency stop key designed for direct wiring. The C9900-E897 is identified as a service-phase product.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePush-button extension for CP6x23-00xx and CP7x23-00xx devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for 15-inch Control Panels and Panel PCs without keyboard\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRight-side installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e20 Siemens Signum square push-button keys\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e30 x 30 mm push-button format\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated signal lamps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplaceable labels for individual push-button identification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne normally-open contact per push-button transmitted through USB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecond normally-open contact available through a terminal row\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal lamp control transmitted through USB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne directly wireable Siemens Signum emergency stop key\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMachine operator stations using CP6xxx or CP7xxx panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLocal machine command and status indication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperator interfaces requiring physical push-button controls\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApplications combining touchscreen operation with dedicated hardware keys\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControl stations requiring a directly wired emergency stop function\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBECKHOFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eC9900-E897\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePush-button extension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Models\u003c\/td\u003e\n\u003ctd\u003eCP6x23-00xx and CP7x23-00xx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e15-inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Position\u003c\/td\u003e\n\u003ctd\u003eRight side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePush-button Quantity\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePush-button Type\u003c\/td\u003e\n\u003ctd\u003eSiemens Signum square\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePush-button Size\u003c\/td\u003e\n\u003ctd\u003e30 x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Lamps\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePush-button USB Contact\u003c\/td\u003e\n\u003ctd\u003e1 normally-open contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect-Wiring Contact\u003c\/td\u003e\n\u003ctd\u003eSecond normally-open contact via terminal row\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Lamp Communication\u003c\/td\u003e\n\u003ctd\u003eUSB only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Stop\u003c\/td\u003e\n\u003ctd\u003e1 Siemens Signum emergency stop key\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Stop Wiring\u003c\/td\u003e\n\u003ctd\u003eDirectly wireable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Lifecycle\u003c\/td\u003e\n\u003ctd\u003eService phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003ctd\u003eTransmission of push-button states and signal lamp control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal row\u003c\/td\u003e\n\u003ctd\u003eDirect wiring of the second normally-open contact for each push-button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect wiring\u003c\/td\u003e\n\u003ctd\u003eEmergency stop connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm that the target device is a compatible CP6x23-00xx or CP7x23-00xx unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify that the panel uses the supported 15-inch configuration without keyboard.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect the extension and connection terminals before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMount the extension on the designated right side of the Control Panel or Panel PC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the USB interface required for push-button transmission and signal lamp operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWire the secondary normally-open contacts only where the machine design requires direct signal connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the emergency stop circuit according to the machine safety design and applicable electrical documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify all push-button, lamp, and emergency stop functions before normal machine operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCommissioning Recommendations\u003c\/h3\u003e\n\u003cp\u003eCheck each push-button individually after installation to verify correct USB signal transmission.\u003c\/p\u003e\n\u003cp\u003eWhere direct-wired secondary contacts are used, verify each circuit independently at the terminal row.\u003c\/p\u003e\n\u003cp\u003eTest all signal lamps through the associated USB-controlled system before releasing the operator station for service.\u003c\/p\u003e\n\u003cp\u003eThe emergency stop circuit should be validated according to the machine's approved safety architecture before operation.\u003c\/p\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106451546475,"sku":"C9900-E897","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/c9900-e897-l55li53wjjd.png?v=1776243645","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-c9900-e897-push-button-extension-for-cp6xxx-and-cp7xxx-control-panels-and-panel-pcs","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}