{"product_id":"beckhoff-c9900-f700-dvi-usb-extended-interface-module","title":"BECKHOFF C9900-F700 DVI\/USB Extended Interface Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF C9900-F700\u003c\/strong\u003e is an integrated DVI\/USB Extended interface module designed for BECKHOFF Control Panels. This connection interface enables the remote operation of physical operator terminals at a distance of up to 50 meters from the controlling Industrial PC. By utilizing DVI-E and USB-E 2.0 technologies, it maintains high-speed data integrity and high-resolution video signals across extended distances without requiring active intermediate repeaters.\u003c\/p\u003e\n\u003cp\u003eThis module acts as the physical receiver interface within the Control Panel, receiving the DVI-E video signal and transmitting bidirectional USB-E 2.0 signals. It is compatible with standard industrial PC outputs when paired with matching transmitter hardware or integrated PC interfaces, making it a reliable solution for distributed machine control architectures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnables remote Control Panel installation up to 50 meters from the Industrial PC.\u003c\/li\u003e\n  \u003cli\u003eDVI-E technology for transmission of standard digital video signals.\u003c\/li\u003e\n  \u003cli\u003eUSB-E 2.0 connection facilitating high-speed USB data transfer up to 480 Mbit\/s.\u003c\/li\u003e\n  \u003cli\u003eIntegrated RJ45 port for the USB-E 2.0 connection line.\u003c\/li\u003e\n  \u003cli\u003eSupports the direct operation of standard USB 2.0 peripherals at the operator terminal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDistributed machine control topologies requiring remote operator interfaces.\u003c\/li\u003e\n  \u003cli\u003eIndustrial environments where the control computer must be isolated from the physical display point.\u003c\/li\u003e\n  \u003cli\u003eMulti-axis machine systems requiring a local display panel connected to a centralized electrical cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eC9900-F700\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eDVI\/USB Extended Interface Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Technology\u003c\/td\u003e\n      \u003ctd\u003eDVI-E, USB-E 2.0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Transmission Distance\u003c\/td\u003e\n      \u003ctd\u003e50 m\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUSB Transmission Rate\u003c\/td\u003e\n      \u003ctd\u003eUp to 480 Mbit\/s (USB 2.0)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Interfaces\u003c\/td\u003e\n      \u003ctd\u003e1 x DVI-E, 1 x RJ45 (USB-E 2.0)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Interfaces\u003c\/td\u003e\n      \u003ctd\u003e2 x USB 2.0 downstream ports\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (via host Control Panel)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to 55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure all electrical power supplies are fully disconnected and locked out before beginning installation or maintenance on the Control Panel.\u003c\/li\u003e\n  \u003cli\u003eInspect the interface connectors on the BECKHOFF C9900-F700 for any physical damage or dust contamination prior to integration.\u003c\/li\u003e\n  \u003cli\u003eMount the interface within the designated slot of the compatible BECKHOFF Control Panel housing, securing all physical clamping mechanisms.\u003c\/li\u003e\n  \u003cli\u003eConnect the specified high-quality DVI-E and USB-E 2.0 cables, ensuring the RJ45 connection is securely locked into place.\u003c\/li\u003e\n  \u003cli\u003eObserve the maximum 50-meter cable limit to prevent signal degradation or communication faults during operation.\u003c\/li\u003e\n  \u003cli\u003eRe-energize the host panel and configure the PC-side transmitter to verify video output and touch\/USB peripheral functionality.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003cp\u003eWhen replacing an existing connection module with the \u003cstrong\u003eBECKHOFF C9900-F700\u003c\/strong\u003e, ensure that the transmitter side connected to the Industrial PC matches the USB-E 2.0 and DVI-E specifications. Check that the current supply voltage of 24 V DC matches the requirements of the host Control Panel assembly. Record the physical cable routing and connection points before removing the legacy unit to prevent incorrect wiring on the new interface module.\u003c\/p\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106463605099,"sku":"C9900-F700","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/c9900-f700-hdc32s3vy1x.png?v=1776243664","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-c9900-f700-dvi-usb-extended-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}