{"product_id":"beckhoff-cx1010-n030-embedded-pc-system-interface-module","title":"Beckhoff CX1010-N030 Embedded PC System Interface Module","description":"\u003ch3\u003eSystem Functional Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBeckhoff CX1010-N030 (CX1010-N030)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dedicated dual-channel serial system interface expansion module designed for the modular CX1010 Embedded PC hardware architecture. Deployed extensively across industrial factory automation nodes, remote environmental monitoring stations, and centralized material tracking lines, this module extends the physical connectivity of the primary CPU. By providing dedicated local hardware communication ports, it offloads serial processing from the core processing unit, ensuring deterministic cycle execution times and avoiding data packet loss during high-speed data streams.\u003c\/p\u003e\n\u003ch3\u003eHardware Interconnect and Electrical Profile\u003c\/h3\u003e\n\u003cp\u003eThis compact system interface populates the local expansion bus, drawing its operational power directly from the main system bus connection via the upstream CX1100-xxxx power supply module series. The physical interface provides two independent RS232 channels designated as COM1 and COM2, routed through two rugged 9-pin D-sub male plug connectors. Capable of driving transmission rates up to a maximum baud rate of 115 kbaud, the hardware features built-in noise filters to preserve signal integrity against electromagnetic discharge. The module is engineered under strict architectural constraints and cannot be combined on the same stack with N031 or N041 interface variants.\u003c\/p\u003e\n\u003ch3\u003eTechnical Performance Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCX1010-N030\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBeckhoff Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGermany\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eComponent Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Interface Serial Expansion Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x COM1 + 1 x COM2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Interface Signaling\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS232 Serial Architecture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnection Hardware\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x D-sub plug, 9-pin male layout\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Transmission Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e115 kbaud\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBus Compatibility Limit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot combinable with N031 or N041 options\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWorking Power Infrastructure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePowered via system bus (through CX1100-xxxx modules)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 deg C (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Relative Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95 %, no condensation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIngress Protection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 Open Type Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMechanical Dimensions (W x H x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19 mm x 100 mm x 51 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Structural Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eapprox. 80 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Gross Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg (Enclosed in large-lot industrial packaging)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Diagnostics and FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do you assign the COM port numbers inside TwinCAT if the system fails to discover the serial interface?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePhysical configuration blocks are not required. Open the TwinCAT System Manager software, navigate to the I\/O Devices tree, and scan for active hardware slices linked to the CX1010 master node. Once detected, the software automatically maps COM1 and COM2 to corresponding internal serial device registers. If mapping fails, verify that the upstream CX1100 power supply module is passing adequate current and that the underlying bus contacts are free of oxide contamination.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does the system manual state that the CX1010-N030 cannot be used alongside the N031 or N041 modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe underlying internal system bus of the CX1010 controller allocates specific hardware address lines and interrupt registers for external serial interface expansions. The CX1010-N030 (RS232), N031 (RS422\/RS485), and N041 (RS232 with isolation) share identical internal address vectors. Attempting to lock these modules together on the same physical stack causes a hardware resource conflict, triggering a firmware boot fault and preventing the TwinCAT runtime from entering operational mode.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary troubleshooting protocols if data corruption occurs at the maximum speed of 115 kbaud?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRS232 signals use single-ended voltage levels which are susceptible to external electromagnetic noise over distance. First, ensure that the connection length between the 9-pin D-sub plug and the peripheral device sits well below the maximum standard length of 15 meters. Next, check that the serial line uses a high-quality shielded twisted-pair cable, and verify that the D-sub metallic hood makes low-impedance contact with the enclosure ground plate.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Commissioning and Installation Directives\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Segment Mechanical Engagement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrior to energizing the controller rack, align the side guide rails of the CX1010-N030 with the left-hand interface of the CX1010 Embedded PC or adjacent expansion module. Slide the unit straight back until the internal PC104 bus connectors seat firmly together and the mechanical locking clips latch onto the standard DIN rail. Do not force the module at an angle to prevent damaging the precision internal connection pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eD-Sub Plug Retaining Screw Torque:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen landing the 9-pin female cable connector onto the module's D-sub plug, verify pin alignment to avoid bending the interface pins. Tighten the two integrated side retaining screws evenly using a precision screwdriver. Securely locking these screws provides continuous structural strain relief, protecting the internal solder joints of the module from mechanical vibrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Enclosure Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis expansion card carries an IP20 rating and must be deployed within a clean, sealed industrial control cabinet. Maintain an open clearance gap of at least 30 mm above and below the module assembly to allow natural convective airflow. Periodically remove any accumulated non-conductive dust or environmental particles from the ventilation slits to ensure the unit operates safely within its 0 to +55 deg C thermal envelope.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106631901547,"sku":"CX1010-N030","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cx1010-n030-bu4531isemr.png?v=1776244114","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-cx1010-n030-embedded-pc-system-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}