{"product_id":"beckhoff-cx2020-0112-embedded-pc-basic-cpu-module","title":"BECKHOFF CX2020-0112 Embedded PC Basic CPU Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF CX2020-0112\u003c\/strong\u003e is an Embedded PC basic CPU module designed for high-performance DIN rail mounting. Equipped with an Intel Celeron 827E single-core processor running at 1.4 GHz, this industrial controller provides dependable processing capabilities for medium-to-high complexity PLC and motion control tasks. Currently in its service phase, this module is a stable and mature automation component ideal for system maintenance, direct machine replacements, and legacy line retrofits.\u003c\/p\u003e\n\u003cp\u003eThis controller features 2 GB of DDR3 RAM as standard and 128 kB of integrated, non-volatile NOVRAM for persistent data storage without requiring an external UPS. The basic CPU module connects directly to a system power supply module from the CX2100 series, allowing automatic detection and adaptation to either E-bus (EtherCAT Terminals) or K-bus (Bus Terminals) I\/O systems. Interface options include dual independent Gigabit Ethernet ports, a DVI-I video output, four USB 2.0 ports, and a factory-configurable option slot for flexible interface expansion.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSingle-core Intel Celeron 827E processor operating at 1.4 GHz for reliable, deterministic control.\u003c\/li\u003e\n  \u003cli\u003e2 GB DDR3 RAM main memory for robust application handling.\u003c\/li\u003e\n  \u003cli\u003e128 kB integrated NOVRAM for reliable storage of critical variables and status data during power loss.\u003c\/li\u003e\n  \u003cli\u003eDual RJ45 10\/100\/1000 Mbit\/s independent Ethernet interfaces to segregate control and corporate networks.\u003c\/li\u003e\n  \u003cli\u003eSupport for automatic recognition and execution of E-bus (EtherCAT) and K-bus (Bus Terminal) I\/O structures.\u003c\/li\u003e\n  \u003cli\u003eModular hardware design allowing the addition of fieldbus, serial, or network expansion interfaces.\u003c\/li\u003e\n  \u003cli\u003ePassive cooling design under standard environmental conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial PLC execution and multi-axis motion control applications.\u003c\/li\u003e\n  \u003cli\u003eDirect replacement of existing machine controllers in legacy installations.\u003c\/li\u003e\n  \u003cli\u003eDistributed control systems needing localized processing power with dual-network segment architecture.\u003c\/li\u003e\n  \u003cli\u003eData logging and HMI integration utilizing local high-speed processing and display outputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eProcessor and Memory\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eCX2020-0112\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProcessor Type\u003c\/td\u003e\n      \u003ctd\u003eIntel Celeron 827E (1.4 GHz, single-core)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Memory (RAM)\u003c\/td\u003e\n      \u003ctd\u003e2 GB DDR3 RAM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePersistent Memory\u003c\/td\u003e\n      \u003ctd\u003e128 kB NOVRAM integrated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFlash Memory Slot\u003c\/td\u003e\n      \u003ctd\u003eCFast card slot (supports 20 GB or 40 GB depending on OS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eInterfaces and Diagnostics\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEthernet Ports\u003c\/td\u003e\n      \u003ctd\u003e2 x RJ45 (10\/100\/1000 Mbit\/s, independent)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVideo Output\u003c\/td\u003e\n      \u003ctd\u003e1 x DVI-I\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUSB Ports\u003c\/td\u003e\n      \u003ctd\u003e4 x USB 2.0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOptional Slot Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x slot for factory-configured optional interface\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDiagnostic LEDs\u003c\/td\u003e\n      \u003ctd\u003e1 x Power, 1 x TC Status, 1 x Flash Access, 2 x Bus Status\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Clock\u003c\/td\u003e\n      \u003ctd\u003eInternal battery-backed clock (battery exchangeable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical and Mechanical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n      \u003ctd\u003eVia CX power supply module (24 V DC, -15 percent \/ +20 percent)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax. Power Consumption\u003c\/td\u003e\n      \u003ctd\u003e21 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eI\/O Connection System\u003c\/td\u003e\n      \u003ctd\u003eDirect E-bus or K-bus connection with automatic detection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e144 mm x 99 mm x 91 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eApprox. 1160 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Class\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eEnvironmental and Safety\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e95 percent, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity \/ Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals and Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eSoftware and Platform Integration\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Systems\u003c\/td\u003e\n      \u003ctd\u003eWindows Embedded Compact 7, Windows Embedded Standard 7 P, Windows 10 IoT Enterprise, TwinCAT\/BSD\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Software Compatibility\u003c\/td\u003e\n      \u003ctd\u003eTwinCAT 2 runtime, TwinCAT 3 runtime (XAR)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTwinCAT 3 Platform Level\u003c\/td\u003e\n      \u003ctd\u003ePerformance Plus (50)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Type\u003c\/th\u003e\n      \u003cth\u003eFunction and Configuration\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLAN 1 \/ LAN 2\u003c\/td\u003e\n      \u003ctd\u003eIndependent Gigabit RJ45 connection points for fieldbus and corporate communication.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDVI-I\u003c\/td\u003e\n      \u003ctd\u003eDirect video connection supporting analog or digital monitors for visualization.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUSB 2.0 (4 Ports)\u003c\/td\u003e\n      \u003ctd\u003eConnection for input peripherals, license dongles, and external diagnostic media.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePC-Cartridge Connection\u003c\/td\u003e\n      \u003ctd\u003eInternal connection bus linking the module directly to power supply and I\/O units.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure all electrical power is completely switched off before mounting or servicing the system.\u003c\/li\u003e\n  \u003cli\u003eMount the CX2020-0112 CPU module onto a standard 35 mm DIN rail (EN 60715) with an integrated CX power supply unit.\u003c\/li\u003e\n  \u003cli\u003eAlign the slide mechanism with the DIN rail and push the module firmly until the latch snaps securely in place.\u003c\/li\u003e\n  \u003cli\u003eEnsure that adjacent system modules (such as I\/O terminals and power supplies) are properly aligned and their lateral contact rails engage seamlessly.\u003c\/li\u003e\n  \u003cli\u003eConnect the ground \/ functional earth wire to the power supply unit terminal to prevent electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003eVerify that the ventilation slots on the top and bottom of the housing remain clear to allow passive cooling.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003cp\u003eWhen replacing a \u003cstrong\u003eBECKHOFF CX2020-0112\u003c\/strong\u003e unit in an existing control system, it is highly recommended to perform a full system backup before hardware removal. Ensure that the configuration, licenses, and variables stored on the CFast card are documented or backed up. Verify that the system's TwinCAT platform level (Level 50) and runtime version match the software configuration of your application before restoring power.\u003c\/p\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106397774187,"sku":"CX2020-0112","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cx2020-0112-jgxixlxkctn.png?v=1776244159","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-cx2020-0112-embedded-pc-basic-cpu-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}