{"product_id":"beckhoff-cx5020-0110-embedded-pc-cpu-module","title":"BECKHOFF CX5020-0110 Embedded PC CPU Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF CX5020-0110\u003c\/strong\u003e is a DIN-rail-mountable Embedded PC designed for low-to-medium performance industrial control and automation tasks. Equipped with an Intel Atom Z530 processor running at 1.6 GHz, this modular controller integrates the central processing unit, power supply, and direct I\/O interfaces within a single compact housing. It is engineered to deliver reliable automation control for systems requiring precise real-time operations.\u003c\/p\u003e\n\n\u003cp\u003eA key capability of the \u003cstrong\u003eBECKHOFF CX5020-0110\u003c\/strong\u003e is its dual-bus system integration. The hardware automatically detects and interfaces with either K-bus (standard Bus Terminals) or E-bus (high-speed EtherCAT Terminals) connection technologies on the right-hand side, providing immense flexibility when scaling or configuring local I\/O configurations. The integrated 1-second UPS ensures that up to 1 MB of critical persistent application data is written to the Compact Flash card in the event of an unexpected power failure.\u003c\/p\u003e\n\n\u003cp\u003eFor communication and expansion, the module features dual independent Gigabit Ethernet ports, four USB 2.0 ports, a DVI-D video output, and a dedicated slot for an optional interface module. This allows the controller to adapt to specific fieldbus protocols or additional communication networks while maintaining a highly compact physical footprint on the DIN rail.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIntel Atom Z530 processor (1.6 GHz clock frequency, single-core execution)\u003c\/li\u003e\n  \u003cli\u003eAutomatic recognition and hardware-level switching between E-bus (EtherCAT) and K-bus (Bus Terminals)\u003c\/li\u003e\n  \u003cli\u003eIntegrated 1-second UPS for up to 1 MB of persistent data preservation on the Compact Flash card\u003c\/li\u003e\n  \u003cli\u003eTwo independent RJ45 10\/100\/1000 Mbit\/s Ethernet interfaces for high-speed networking and integration\u003c\/li\u003e\n  \u003cli\u003eCompact Flash card slot for persistent storage and operating system files, equipped with a 128 MB card\u003c\/li\u003e\n  \u003cli\u003eInternal exchangeable battery-backed clock for precise system date and time synchronization\u003c\/li\u003e\n  \u003cli\u003eBuilt-in diagnostic LEDs for power, TwinCAT status, flash card access, and bus communication statuses\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eModular machine control systems utilizing localized E-bus or K-bus I\/O layouts\u003c\/li\u003e\n  \u003cli\u003eDistributed industrial networks requiring localized TwinCAT runtime control\u003c\/li\u003e\n  \u003cli\u003eProcess monitoring and edge-computing applications with DVI-D diagnostic display setups\u003c\/li\u003e\n  \u003cli\u003eEmbedded automation environments subject to extended operating temperatures from -25 to +60 degC\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003eGeneral and Processor\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel Number\u003c\/td\u003e\n      \u003ctd\u003eCX5020-0110\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProcessor\u003c\/td\u003e\n      \u003ctd\u003eIntel Atom Z530 (1.6 GHz clock speed, 1 core)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMain Memory\u003c\/td\u003e\n      \u003ctd\u003e512 MB RAM (expandable ex factory to 1 GB)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFlash Memory\u003c\/td\u003e\n      \u003ctd\u003eCompact Flash slot (128 MB card included, expandable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePersistent Memory\u003c\/td\u003e\n      \u003ctd\u003e1-second UPS (1 MB on Compact Flash card)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTwinCAT 3 Platform Level\u003c\/td\u003e\n      \u003ctd\u003ePerformance (40)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003eElectrical and I\/O Performance\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Type\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20% tolerance)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax. Power Consumption\u003c\/td\u003e\n      \u003ctd\u003e13 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Supply E-bus\/K-bus\u003c\/td\u003e\n      \u003ctd\u003e2 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eI\/O Connection System\u003c\/td\u003e\n      \u003ctd\u003eDirect E-bus (EtherCAT Terminals) or K-bus (Bus Terminals), automatic switching\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003eInterfaces and Connectivity\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNetwork Interfaces\u003c\/td\u003e\n      \u003ctd\u003e2 x RJ45 10\/100\/1000 Mbit\/s (independent)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDisplay Port\u003c\/td\u003e\n      \u003ctd\u003e1 x DVI-D\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUSB Interfaces\u003c\/td\u003e\n      \u003ctd\u003e4 x USB 2.0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExpansion Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x Optional slot for custom interface expansion\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDiagnostics LEDs\u003c\/td\u003e\n      \u003ctd\u003e1 x Power, 1 x TC Status, 1 x Flash Access, 2 x Bus Status\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003eMechanical and Environmental\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e106 mm x 100 mm x 92 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eApprox. 575 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration and Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIP Protection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Type\u003c\/th\u003e\n      \u003cth\u003eFunction and Configuration\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRJ45 Ports\u003c\/td\u003e\n      \u003ctd\u003eDual independent gigabit network interfaces for fieldbus connections or host networks\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDVI-D Port\u003c\/td\u003e\n      \u003ctd\u003eDigital video display output for operator interface connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUSB Ports (4x)\u003c\/td\u003e\n      \u003ctd\u003eConnection of external storage, diagnostic tools, or input peripherals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOptional Slot\u003c\/td\u003e\n      \u003ctd\u003eAccepts interface modules for additional fieldbus protocols or expansions\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLocal Bus Terminal\u003c\/td\u003e\n      \u003ctd\u003eRight-side direct extension for BECKHOFF K-bus or E-bus I\/O modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure that the power supply to the entire control cabinet is completely de-energized before mounting, removing, or wiring the controller.\u003c\/li\u003e\n  \u003cli\u003ePosition the controller on a standard 35 mm DIN rail (EN 60715) with vertical mounting orientation to facilitate proper convective cooling airflow.\u003c\/li\u003e\n  \u003cli\u003eVerify that the external DC power supply aligns with the 24 V DC requirements, incorporating proper terminal polarity and wire routing.\u003c\/li\u003e\n  \u003cli\u003eSecure functional grounding (PE) connections to the DIN rail or backplate to ensure stable electromagnetic compatibility (EMC) performance.\u003c\/li\u003e\n  \u003cli\u003eInsert terminal modules (E-bus or K-bus) into the right-hand interface slot. The unit will automatically detect the terminal platform on initial startup boot sequences.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106446532971,"sku":"CX5020-0110","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cx5020-0110-fdqrdkzisa3.png?v=1776244242","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-cx5020-0110-embedded-pc-cpu-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}