{"product_id":"beckhoff-cx5140-0122-cx5100-series-embedded-pc","title":"Beckhoff CX5140-0122 CX5100 Series Embedded PC","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Engineered for medium-to-high complexity automation tasks, the \u003cstrong\u003eBeckhoff CX5140-0122\u003c\/strong\u003e Embedded PC brings quad-core processing power directly to the DIN rail. This controller integrates an \u003cstrong\u003eIntel Atom E3845\u003c\/strong\u003e 1.91 GHz processor, providing high-speed execution for TwinCAT-based control systems. With native support for both \u003cstrong\u003eE-bus and K-bus\u003c\/strong\u003e I\/O terminals, the unit automatically detects connected modules, facilitating seamless migration and expansion in diverse industrial environments.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Technical Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuad-Core Processing:\u003c\/strong\u003e Intel Atom E3845 CPU running at 1.91 GHz for deterministic control loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual I\/O Interface:\u003c\/strong\u003e Automatic recognition and support for Beckhoff E-bus (EtherCAT) and K-bus (Bus Terminal) systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated 1-Second UPS:\u003c\/strong\u003e Hardware-based persistent memory protection (1 MB on CFast card) to prevent data loss during sudden power failures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Connectivity:\u003c\/strong\u003e Dual independent RJ45 Gigabit Ethernet ports, four USB 2.0 ports, and a DVI-I diagnostic interface.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePassive Thermal Design:\u003c\/strong\u003e Fanless operation across a wide temperature range from -25 to +60 degC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMachine Tool Control:\u003c\/strong\u003e High-speed PLC and motion control execution via TwinCAT 3.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProcess Automation:\u003c\/strong\u003e Distributed control systems requiring robust communication interfaces and fieldbus integration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInfrastructure \u0026amp; Energy:\u003c\/strong\u003e Remote monitoring and control in substations, water treatment plants, and wind turbines.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Environments:\u003c\/strong\u003e Deployable in Zone 2\/22 locations when configured with the optional CX2900-0107 thermal\/protection package.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eValue \/ Configuration\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBeckhoff Automation GmbH \u0026amp; Co. KG\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCX5140-0122\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIntel Atom E3845, 1.91 GHz (4 Cores)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSystem Memory\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e4 GB DDR3 RAM (Non-expandable)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eStorage Slots\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1 x CFast card slot, 1 x microSD card slot (Cards not included)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePersistent Memory\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIntegrated 1-second UPS (1 MB on CFast card)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCommunication Interfaces\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2 x RJ45 (10\/100\/1000 Mbit\/s), 1 x DVI-I, 4 x USB 2.0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eI\/O Bus Connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eE-bus (EtherCAT) or K-bus (Bus Terminal), automatic recognition\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eE-bus\/K-bus Current Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2 A maximum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePower Supply Input\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e16 W (Standard), 23 W (During UPS charging)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eTwinCAT Platform Level\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePerformance Plus (Level 50)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-25 to +60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-40 to +85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eRelative Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e95%, non-condensing\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProtection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIP20\u003c\/td\u003e\n              \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e142 mm x 100 mm x 92 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1095 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The CX5140-0122 is a quad-core alternative to the dual-core CX5130 series. It operates at TwinCAT 3 Platform Level 50 (Performance Plus), meaning any licenses transferred from lower-tier controllers (such as Level 40 Economy Plus units) must be upgraded to match this platform level. It maintains physical and electrical backplane compatibility with existing CX5010 and CX5020 installations, though software configurations must account for the updated Intel Atom E3845 architecture.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  \u003cstrong\u003eThermal Management:\u003c\/strong\u003e Although fanless, the CX5140-0122 relies on natural convection. It must be mounted vertically on a horizontal DIN rail. Maintaining a minimum clearance of 30 mm above and below the unit is mandatory to prevent thermal throttling when operating near the upper limit of 60 degC.\u003cbr\u003e\n  \u003cstrong\u003eUPS Functionality:\u003c\/strong\u003e The integrated 1-second UPS requires a functional internal capacitive storage system. This UPS is designed solely to write persistent data (up to 1 MB) to the CFast card during a power loss event; it is not a system-level runtime UPS. Ensure the TwinCAT boot project is configured to trigger the write routine on power loss.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  When wiring the 24 V DC power supply, ensure the supply line is fused externally. The E-bus\/K-bus auto-detection occurs during the initial boot phase. If changing terminal types (e.g., swapping K-bus terminals for EtherCAT E-bus terminals), a full system cold restart is required for the controller to re-map the physical backplane interface. Ensure the total current draw of connected terminals does not exceed the 2 A backplane limit; if exceeded, a power supply terminal (e.g., CX2100-0xxx) must be integrated.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cspan style=\"color: #9b2c2c;\"\u003e\n    Disconnect all electrical power sources before mounting, wiring, or removing the CX5140-0122. Verify that the 24 V DC supply is completely de-energized. Failure to isolate power can result in permanent damage to the internal processor, backplane ASIC, or connected I\/O terminals. Ensure electrostatic discharge (ESD) protection protocols are followed when handling CFast or microSD storage media.\n  \u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the CX5140-0122 onto a standard 35 mm DIN rail (EN 60715) by hooking the top of the mounting clip over the rail and pressing down until it snaps securely into place.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the functional ground (PE) wire directly to the grounding terminal of the power supply connector to ensure proper EMC shielding and noise immunity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eInsert a compatible, industrially rated CFast card containing the operating system and TwinCAT runtime into the designated slot before applying power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the 24 V DC power cables to the terminal block, verifying correct polarity, and power on the system to initiate the automatic I\/O bus scan.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106408456555,"sku":"CX5140-0122","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cx5140-0122-em2cog3male.png?v=1776244295","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-cx5140-0122-cx5100-series-embedded-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}