{"product_id":"beckhoff-ej1859-ethercat-plug-in-module","title":"Beckhoff EJ1859 EtherCAT Plug-in Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEJ1859\u003c\/strong\u003e is a \u003cstrong\u003ecombi plug-in module\u003c\/strong\u003e from the \u003cstrong\u003eEtherCAT\u003c\/strong\u003e range, designed to provide efficient signal management with a combined configuration of \u003cstrong\u003e8 digital inputs and 8 digital outputs\u003c\/strong\u003e. This module operates at a nominal voltage of \u003cstrong\u003e24 V DC\u003c\/strong\u003e and is engineered for high-density, space-saving applications. Featuring a compact 30 g design, it supports ohmic, inductive, and lamp loads, with outputs capable of handling a maximum current of 0.5 A per channel, ensuring versatile performance in industrial automation tasks.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCombined configuration: 8 inputs and 8 outputs\u003c\/li\u003e\n\u003cli\u003e24 V DC nominal operating voltage\u003c\/li\u003e\n\u003cli\u003e0.5 A output current capacity per channel\u003c\/li\u003e\n\u003cli\u003eSupports ohmic, inductive, and lamp loads\u003c\/li\u003e\n\u003cli\u003eReverse voltage protection included\u003c\/li\u003e\n\u003cli\u003eEtherCAT plug-in design for high-density integration\u003c\/li\u003e\n\u003cli\u003eElectrical isolation of 500 V between E-bus and field potential\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed industrial automation\u003c\/li\u003e\n\u003cli\u003eHigh-density sensor and actuator interfacing\u003c\/li\u003e\n\u003cli\u003eCompact machine control cabinets\u003c\/li\u003e\n\u003cli\u003eMotion and process control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBeckhoff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 inputs + 8 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Output Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A (per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Filter\u003c\/td\u003e\n\u003ctd\u003etyp. 3.0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd\u003e500 V (E-bus\/field potential)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003etyp. 90 mA (E-bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eapprox. 30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure proper placement in the designated slot for plug-in modules. Consult the system documentation for required installation positions to maintain IP20 rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect field devices according to the terminal mapping provided in the documentation; ensure polarity is respected for the 24 V DC supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Utilize the integrated reverse voltage protection to safeguard against accidental miswiring during installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure the ambient temperature remains within the -25 to +60 deg C range; avoid environments with condensation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Verify that the total load connected does not exceed the power supply limitations of the module or the backplane power rail.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106590548331,"sku":"EJ1859","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ej1859-vbb4kelxway.png?v=1776244335","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ej1859-ethercat-plug-in-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}