{"product_id":"beckhoff-ej3058-ethercat-plug-in-module","title":"BECKHOFF EJ3058 EtherCAT Plug-In Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF EJ3058\u003c\/strong\u003e is an 8-channel analog input plug-in module designed for direct installation on application-specific signal distribution boards. Part of the compact EJ series, this module is optimized for mass production machinery, enabling quick assembly and reducing point-to-point wiring errors. It is configured to acquire single-ended analog current signals in the standard 4 to 20 mA range with high density and accuracy.\u003c\/p\u003e\n\u003cp\u003eThe module processes raw analog signals with a 12-bit physical resolution, which is transmitted to the higher-level controller in a 16-bit representation including the sign. Configurable process parameters, including selectable digital filters (FIR\/IIR) and limit value monitoring, allow control engineers to fine-tune signal acquisition for specific mechanical systems. The module remains electrically isolated up to 500 V between the internal E-bus and the field-side potential to maintain signal integrity in demanding industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEight single-ended analog input channels for 4 to 20 mA standard current loops.\u003c\/li\u003e\n  \u003cli\u003eDirect plug-in design for application-specific signal distribution boards, eliminating manual DIN-rail terminal wiring.\u003c\/li\u003e\n  \u003cli\u003e12-bit physical analog-to-digital conversion resolution (presented as a 16-bit integer).\u003c\/li\u003e\n  \u003cli\u003eConfigurable signal processing with activatable digital FIR and IIR filters to suppress high-frequency noise.\u003c\/li\u003e\n  \u003cli\u003eIntegrated limit value monitoring for proactive system diagnostics and fault prevention.\u003c\/li\u003e\n  \u003cli\u003eE-bus powered internal electronics, drawing a typical current consumption of 130 mA.\u003c\/li\u003e\n  \u003cli\u003eElectrical isolation of 500 V between the internal E-bus communication lines and the field potential.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-volume series machine building requiring customized, PCB-based distribution wiring.\u003c\/li\u003e\n  \u003cli\u003eMulti-channel analog signal acquisition from industrial pressure, level, and temperature transmitters.\u003c\/li\u003e\n  \u003cli\u003eSpace-constrained control cabinets where traditional terminal block architectures are impractical.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003eGeneral Specs\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEJ3058\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT plug-in module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 (single-ended)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eSignal and Electrical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSignal Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInternal Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 85 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Filter Limit Frequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 kHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConversion Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.25 ms (default setting, configurable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 bit (16 bit presentation including sign)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasurement Error\/Uncertainty\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; ±0.3% (relative to full scale value)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003emax. 30 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 V (E-bus \/ field potential)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption E-bus\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 130 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupply Voltage Electronics\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003evia E-bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMechanical and Environmental Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eapprox. 30 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration\/Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity\/Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the system and all external supply lines are fully de-energized before mounting or servicing.\u003c\/li\u003e\n  \u003cli\u003eInspect the plug-in connection pins on the rear of the EJ3058 module for straightness and cleanliness before insertion.\u003c\/li\u003e\n  \u003cli\u003eAlign the module carefully with the pin sockets on the custom-designed signal distribution board.\u003c\/li\u003e\n  \u003cli\u003ePress the module down evenly until the mechanical retaining elements seat properly to ensure a reliable electrical connection.\u003c\/li\u003e\n  \u003cli\u003eConfigure the signal parameters, filters, and limit values within the TwinCAT System Manager software environment.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106500272491,"sku":"EJ3058","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ej3058-bb04zlscobf.png?v=1776244340","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ej3058-ethercat-plug-in-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}