{"product_id":"beckhoff-el1889-ethercat-terminal","title":"BECKHOFF EL1889 EtherCAT Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF EL1889 digital input terminal is designed to acquire binary control signals from the physical field level and transmit them to the higher-level automation controller via the EtherCAT network. Featuring a highly compact High Density (HD) housing, this terminal provides sixteen distinct input points within a 12 mm physical width to optimize control cabinet space utilization.\u003c\/p\u003e\n\n\u003cp\u003eThis terminal is built for 1-wire connection technology and operates with ground-switching (sinking) sensors. The BECKHOFF EL1889 processes 24 V DC signals, identifying a logical \"1\" status at low voltage levels (0 to 7 V) and a logical \"0\" status at higher voltage levels (18 to 30 V). High-density connection terminals allow direct wiring of solid-wire conductors without additional tools, facilitating efficient high-density installations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides 16 digital input points in a compact 12 mm housing width\u003c\/li\u003e\n  \u003cli\u003eEngineered for ground-switching (sinking) input characteristics\u003c\/li\u003e\n  \u003cli\u003eUtilizes space-saving 1-wire connection technology\u003c\/li\u003e\n  \u003cli\u003eEquipped with integrated signal status LEDs for each input channel\u003c\/li\u003e\n  \u003cli\u003eHigh Density (HD) terminal design with toolless direct plug-in connection for solid conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-density distributed input\/output configurations within automated machine environments\u003c\/li\u003e\n  \u003cli\u003eDirect integration with ground-switching (sinking) proximity sensors, limit switches, and photoelectric sensors\u003c\/li\u003e\n  \u003cli\u003eEtherCAT-based control systems demanding high-density signal acquisition within limited cabinet space\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eEL1889\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT Terminal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDesign Form\u003c\/td\u003e\n      \u003ctd\u003eHD (High Density) housing with signal LEDs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003ePolycarbonate\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\"0\" Signal Voltage\u003c\/td\u003e\n      \u003ctd\u003e18 to 30 V (Sinking Logic)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\"1\" Signal Voltage\u003c\/td\u003e\n      \u003ctd\u003e0 to 7 V (Sinking Logic)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Current\u003c\/td\u003e\n      \u003ctd\u003etyp. 3.0 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Filter Delay\u003c\/td\u003e\n      \u003ctd\u003etyp. 3.0 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption E-bus\u003c\/td\u003e\n      \u003ctd\u003etyp. 110 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption Power Contacts\u003c\/td\u003e\n      \u003ctd\u003etyp. 35 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Load Power Contacts (Imax)\u003c\/td\u003e\n      \u003ctd\u003e10 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003e500 V (E-bus\/field potential)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eConnection and Mechanical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Technology\u003c\/td\u003e\n      \u003ctd\u003e1-wire\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e16\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSolid Wire Connection Cross-Section\u003c\/td\u003e\n      \u003ctd\u003e0.08 to 1.5 mm² (AWG 28 to 16)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStranded Wire Connection Cross-Section\u003c\/td\u003e\n      \u003ctd\u003e0.25 to 1.5 mm² (AWG 22 to 16)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFine-Stranded Wire (with Ferrule)\u003c\/td\u003e\n      \u003ctd\u003e0.14 to 0.75 mm² (AWG 26 to 19)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStripping Length\u003c\/td\u003e\n      \u003ctd\u003e8 to 9 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e12 mm x 100 mm x 68 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting\u003c\/td\u003e\n      \u003ctd\u003e35 mm DIN rail (conforming to EN 60715) with lock\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eEnvironmental and Regulatory\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e95%, no condensation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration\/Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\/Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Class\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals\u003c\/td\u003e\n      \u003ctd\u003eCE, UL, ATEX (II 3 G Ex nA IIC T4 Gc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the entire industrial control system and power supplies are completely de-energized before mounting or wiring the terminal.\u003c\/li\u003e\n  \u003cli\u003eMount the terminal onto a standard 35 mm DIN rail conforming to EN 60715, securing it using the integrated locking mechanism.\u003c\/li\u003e\n  \u003cli\u003eSlide successive terminals together using the double slot-and-key design to ensure correct E-bus and power contact engagement.\u003c\/li\u003e\n  \u003cli\u003eConnect the solid wiring by pushing the conductor directly into the plug-in terminal point. For fine-stranded conductors, press the spring actuator down with a screwdriver before inserting the wire.\u003c\/li\u003e\n  \u003cli\u003eEnsure field power voltage is correctly configured within the nominal 24 V DC tolerance range before turning on the power.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106532483435,"sku":"EL1889","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/el1889-1nms5ac3exs.png?v=1776244393","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-el1889-ethercat-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}