{"product_id":"beckhoff-el2014-ethercat-terminal","title":"BECKHOFF EL2014 EtherCAT Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF EL2014\u003c\/strong\u003e is a 4-channel digital output terminal designed for the EtherCAT I\/O system. It outputs binary 24 V DC control signals to field-level actuators with a maximum output current of 0.5 A per channel. Built with an integrated electronic diagnostics system, this terminal ensures high system availability by continuously monitoring operating parameters and status.\u003c\/p\u003e\n\u003cp\u003eUtilizing 2-wire connection technology, the \u003cstrong\u003eBECKHOFF EL2014\u003c\/strong\u003e allows direct connection of actuators without requiring additional external potential distribution. Actuators such as solenoid valves, contactors, and indicator lamps can be wired directly, optimizing control cabinet space and simplifying overall system architecture.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFour digital output channels for 24 V DC field actuators\u003c\/li\u003e\n  \u003cli\u003e2-wire connection technology for direct wiring of actuators\u003c\/li\u003e\n  \u003cli\u003eShort-circuit proof outputs with reverse voltage protection\u003c\/li\u003e\n  \u003cli\u003eComprehensive channel-specific diagnostics including overtemperature, PowerFail, and short circuit\u003c\/li\u003e\n  \u003cli\u003eDiagnostic communication integrated directly into the process data (20-bit diagnostic image)\u003c\/li\u003e\n  \u003cli\u003eLocal status and diagnostic LEDs for quick physical verification\u003c\/li\u003e\n  \u003cli\u003e500 V electrical isolation between the internal E-bus and field potential\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eControl of ohmic, inductive, and lamp loads in automated machinery\u003c\/li\u003e\n  \u003cli\u003eSolenoid valve and contactor control with integrated fault monitoring\u003c\/li\u003e\n  \u003cli\u003eDistributed industrial control systems demanding localized diagnostic coverage\u003c\/li\u003e\n  \u003cli\u003eHazardous area applications requiring certified intrinsically safe-adjacent equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eEL2014\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT Terminal (Digital Output)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n      \u003ctd\u003e4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Technology\u003c\/td\u003e\n      \u003ctd\u003e2-wire\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical Data\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 % \/ +20 %)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Type\u003c\/td\u003e\n      \u003ctd\u003eOhmic, inductive, lamp load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax. Output Current\u003c\/td\u003e\n      \u003ctd\u003e0.5 A (short-circuit proof) per channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShort-Circuit Current\u003c\/td\u003e\n      \u003ctd\u003etyp. \u0026lt; 1 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eReverse Voltage Protection\u003c\/td\u003e\n      \u003ctd\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBreaking Energy\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; 150 mJ\/channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption (E-bus)\u003c\/td\u003e\n      \u003ctd\u003etyp. 60 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption (Power Contacts)\u003c\/td\u003e\n      \u003ctd\u003etyp. 15 mA + load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Load Power Contacts\u003c\/td\u003e\n      \u003ctd\u003eImax: 10 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003e500 V (E-bus \/ field potential)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003ePerformance and Diagnostics\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSwitching Times\u003c\/td\u003e\n      \u003ctd\u003etyp. TON: 50 us, typ. TOFF: 100 us\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProcess Image Bit Width\u003c\/td\u003e\n      \u003ctd\u003e4-bit output, 20-bit diagnostics\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDiagnostics Parameters\u003c\/td\u003e\n      \u003ctd\u003eOvertemperature, PowerFail, short circuit (per channel)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDiagnostic Indication\u003c\/td\u003e\n      \u003ctd\u003eProcess data and local diagnostic LEDs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConfiguration\u003c\/td\u003e\n      \u003ctd\u003eVia TwinCAT System Manager\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMechanical and Environmental\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e12 mm x 100 mm x 68 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eapprox. 70 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePluggable Wiring\u003c\/td\u003e\n      \u003ctd\u003eYes (compatible with ESxxxx terminals)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Type\u003c\/td\u003e\n      \u003ctd\u003e35 mm DIN rail (EN 60715) with lock\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSide-by-Side Mounting\u003c\/td\u003e\n      \u003ctd\u003eDouble slot and key connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConductor Types\u003c\/td\u003e\n      \u003ctd\u003eSolid, stranded, and ferruled wire\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConductor Cross-Section (Solid)\u003c\/td\u003e\n      \u003ctd\u003e0.08...2.5 mm² (AWG 28...14)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConductor Cross-Section (Stranded)\u003c\/td\u003e\n      \u003ctd\u003e0.25...2.5 mm² (AWG 28...14)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConductor Cross-Section (Ferrule)\u003c\/td\u003e\n      \u003ctd\u003e0.14...1.5 mm² (AWG 26...16)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStripping Length\u003c\/td\u003e\n      \u003ctd\u003e8...9 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e95 %, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration \/ Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity \/ Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eCompliance and Certifications\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals \/ Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, ATEX, IECEx, cFMus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eATEX Certification\u003c\/td\u003e\n      \u003ctd\u003eII 3 G Ex nA IIC T4 Gc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIECEx Certification\u003c\/td\u003e\n      \u003ctd\u003eEx nA IIC T4 Gc, Ex tc IIIC T135 degC Dc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ecFMus Certification\u003c\/td\u003e\n      \u003ctd\u003eClass I, Division 2, Groups A, B, C, D; Class I, Zone 2, AEx ec IIC T4 Gc\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure that all electrical power supplies are completely de-energized and locked out before starting installation, wiring, or removal.\u003c\/li\u003e\n  \u003cli\u003eMount the terminal onto a standard 35 mm DIN rail conforming to EN 60715, ensuring the locking mechanism engages securely.\u003c\/li\u003e\n  \u003cli\u003eAlign and join adjacent terminals side-by-side using the double slot and key system to establish E-bus and power contact continuity.\u003c\/li\u003e\n  \u003cli\u003eStrip field-side wires to the recommended 8 to 9 mm length. Actuate the spring clamp connection using a standard screwdriver to insert wire conductors.\u003c\/li\u003e\n  \u003cli\u003eCheck that all field connections are tight, ensuring proper assignment for 2-wire outputs before applying potential to the field-side power contacts.\u003c\/li\u003e\n  \u003cli\u003eInitialize and configure the terminal within the TwinCAT System Manager to map diagnostic and output process variables.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106540020075,"sku":"EL2014","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/el2014-qoxfyq3caay.png?v=1776244395","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-el2014-ethercat-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}