{"product_id":"beckhoff-el3144-ethercat-terminal","title":"BECKHOFF EL3144 EtherCAT Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF EL3144\u003c\/strong\u003e is a 4-channel analog input EtherCAT Terminal designed to acquire and process current signals in the range of 0 to 20 mA. Operating with single-ended technology, this module provides high-resolution 16-bit measurement for demanding industrial control and instrumentation tasks.\u003c\/p\u003e\n\u003cp\u003eAs part of the modular BECKHOFF I\/O system, the \u003cstrong\u003eEL3144\u003c\/strong\u003e integrates into EtherCAT networks, delivering rapid signal conversion with a time of approximately 40 µs. The integration of Distributed Clocks (DC) allows high-precision, synchronized measurement across complex setups, making it ideal for synchronized control applications.\u003c\/p\u003e\n\u003cp\u003eHoused in a compact 12 mm terminal enclosure, the device features 500 V electrical isolation between the E-bus and the signal channels. This isolation protects the control system from electromagnetic interference and electrical noise common in field environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFour single-ended analog inputs configured for 0 to 20 mA current loops\u003c\/li\u003e\n  \u003cli\u003eHigh measurement resolution of 16 bits for accurate signal representation\u003c\/li\u003e\n  \u003cli\u003eFast conversion time of approximately 40 µs\u003c\/li\u003e\n  \u003cli\u003eDistributed Clocks (DC) support with synchronization precision under 1 µs\u003c\/li\u003e\n  \u003cli\u003eIntegrated 5 kHz input filter limit frequency to suppress high-frequency noise\u003c\/li\u003e\n  \u003cli\u003eCompact 12 mm DIN rail mountable housing with standard status indication LEDs\u003c\/li\u003e\n  \u003cli\u003eElectrical isolation of 500 V (E-bus to signal voltage) for improved field reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProcess measurement and continuous monitoring systems\u003c\/li\u003e\n  \u003cli\u003eInterfacing with industrial current sensors, including flow meters and pressure transmitters\u003c\/li\u003e\n  \u003cli\u003eClosed-loop feedback systems in machine automation\u003c\/li\u003e\n  \u003cli\u003eHigh-speed, multi-channel analog data acquisition setups\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eEL3144\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT Terminal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e4 (single-ended)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSignal Current\u003c\/td\u003e\n      \u003ctd\u003e0 to 20 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTechnology\u003c\/td\u003e\n      \u003ctd\u003eSingle-ended\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003ePerformance and Signal Processing\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResolution\u003c\/td\u003e\n      \u003ctd\u003e16 bit (including sign)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConversion Time\u003c\/td\u003e\n      \u003ctd\u003eApprox. 40 µs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMeasuring Error\u003c\/td\u003e\n      \u003ctd\u003eLess than ±0.3% (relative to full scale value)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Filter Limit Frequency\u003c\/td\u003e\n      \u003ctd\u003e5 kHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInternal Resistance\u003c\/td\u003e\n      \u003ctd\u003eTyp. 85 ohms + diode voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDistributed Clocks\u003c\/td\u003e\n      \u003ctd\u003eYes (precision under 1 µs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply\u003c\/td\u003e\n      \u003ctd\u003eVia the E-bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption E-bus\u003c\/td\u003e\n      \u003ctd\u003eTyp. 130 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDielectric Strength\u003c\/td\u003e\n      \u003ctd\u003eMax. 30 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003e500 V (E-bus \/ signal voltage)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBit Width in Process Image\u003c\/td\u003e\n      \u003ctd\u003e16 bytes input\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003ePhysical and Mechanical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e12 mm x 100 mm x 68 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eApprox. 60 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting\u003c\/td\u003e\n      \u003ctd\u003e35 mm DIN rail (conforming to EN 60715) with lock\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaterial\u003c\/td\u003e\n      \u003ctd\u003ePolycarbonate\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Type\u003c\/td\u003e\n      \u003ctd\u003eSpring actuation by screwdriver (solid, flexible, or ferrule)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConductor Cross-section (Solid\/Stranded)\u003c\/td\u003e\n      \u003ctd\u003e0.08 to 2.5 mm² (AWG 28 to 14)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConductor Cross-section (Ferrule)\u003c\/td\u003e\n      \u003ctd\u003e0.14 to 1.5 mm² (AWG 26 to 16)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStripping Length\u003c\/td\u003e\n      \u003ctd\u003e8 to 9 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eEnvironmental and Compliance\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e95%, no condensation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration\/Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\/Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals\/Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL, ATEX\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEx Marking\u003c\/td\u003e\n      \u003ctd\u003eII 3 G Ex nA IIC T4 Gc\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the entire automation system and power contacts are fully de-energized before mounting or removing any modules.\u003c\/li\u003e\n  \u003cli\u003eInspect the terminal for physical damage or debris prior to assembly on the mounting rail.\u003c\/li\u003e\n  \u003cli\u003eMount the module onto a standard 35 mm DIN rail (EN 60715), securing the lock mechanism and ensuring standard slot-and-key connection integrity with adjacent units.\u003c\/li\u003e\n  \u003cli\u003eCheck that E-bus contacts align correctly with adjacent terminals to maintain proper electrical continuity.\u003c\/li\u003e\n  \u003cli\u003eStrip field cables to the recommended 8 to 9 mm. Insert conductors into the terminal connections by activating the spring mechanism with a suitable screwdriver.\u003c\/li\u003e\n  \u003cli\u003eProperly ground and shield current loop signals to minimize industrial noise influence on the analog measurements.\u003c\/li\u003e\n  \u003cli\u003eRe-energize the system and run configuration steps via TwinCAT to map the process image and verify channel functionality.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106505711979,"sku":"EL3144","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/el3144-njmd2uhmfgv.png?v=1776244447","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-el3144-ethercat-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}