{"product_id":"beckhoff-el3162-ethercat-terminal","title":"BECKHOFF EL3162 EtherCAT Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF EL3162 is an EtherCAT Terminal featuring two analog input channels designed for voltage signals ranging from 0 to 10 V. Engineered with a 16-bit resolution in a single-ended configuration, this terminal processes analog field signals and transmits them directly to the automation controller via the high-speed EtherCAT network.\u003c\/p\u003e\n\u003cp\u003eIntegrated within the modular BECKHOFF I\/O system, the EL3162 provides advanced signal processing capabilities including activatable FIR and IIR filters, limit value monitoring, and support for distributed clocks to ensure precise time synchronization across the industrial network. Power for the internal electronics is supplied via the E-bus, while standard compact process imagery optimizes data exchange with the master controller.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e2-channel analog input terminal for voltage measurement in the 0 to 10 V range\u003c\/li\u003e\n  \u003cli\u003e16-bit resolution including sign for high-precision data acquisition\u003c\/li\u003e\n  \u003cli\u003eSingle-ended input technology with an internal resistance greater than 200 kOhm\u003c\/li\u003e\n  \u003cli\u003eDistributed clocks support for synchronous data acquisition across the network\u003c\/li\u003e\n  \u003cli\u003eActivatable FIR and IIR filters for adjustable signal conditioning\u003c\/li\u003e\n  \u003cli\u003eIntegrated limit value monitoring for threshold-based event handling\u003c\/li\u003e\n  \u003cli\u003eElectrical isolation of 500 V between the E-bus and signal voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial analog sensor data acquisition and monitoring\u003c\/li\u003e\n  \u003cli\u003eProcess control systems requiring precise voltage measurement\u003c\/li\u003e\n  \u003cli\u003eMachine automation for position, pressure, or flow feedback\u003c\/li\u003e\n  \u003cli\u003eSynchronized data logging applications utilizing distributed clocks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eEL3162\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT Terminal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e2 (single-ended)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply\u003c\/td\u003e\n      \u003ctd\u003eVia the E-bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption E-bus\u003c\/td\u003e\n      \u003ctd\u003eTyp. 170 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption Power Contacts\u003c\/td\u003e\n      \u003ctd\u003e-\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDielectric Strength\u003c\/td\u003e\n      \u003ctd\u003eMax. 30 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003e500 V (E-bus \/ signal voltage)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Load Power Contacts\u003c\/td\u003e\n      \u003ctd\u003eImax: 10 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eSignal and Performance\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSignal Type\u003c\/td\u003e\n      \u003ctd\u003eSingle-ended voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSignal Voltage\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInternal Resistance\u003c\/td\u003e\n      \u003ctd\u003e\u0026gt; 200 kOhm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResolution\u003c\/td\u003e\n      \u003ctd\u003e16 bit (incl. sign)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConversion Time\u003c\/td\u003e\n      \u003ctd\u003e~ 50 us\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMeasuring Error\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; ±0.3 % (relative to full scale value)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Filter Limit Frequency\u003c\/td\u003e\n      \u003ctd\u003e5 kHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDistributed Clocks\u003c\/td\u003e\n      \u003ctd\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBit Width in the Process Image\u003c\/td\u003e\n      \u003ctd\u003e2 x 16 bit input, 2 x 8 bit status\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eConnection and Mechanical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Technology\u003c\/td\u003e\n      \u003ctd\u003eSpring actuation by screwdriver\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Cross-Section Solid Conductor (s)\u003c\/td\u003e\n      \u003ctd\u003e0.08 to 2.5 mm² (AWG 28 to 14)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Cross-Section Stranded Conductor (st)\u003c\/td\u003e\n      \u003ctd\u003e0.08 to 2.5 mm² (AWG 28 to 14)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Cross-Section with Ferrule (f)\u003c\/td\u003e\n      \u003ctd\u003e0.14 to 1.5 mm² (AWG 26 to 16)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStripping Length\u003c\/td\u003e\n      \u003ctd\u003e8 to 9 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePluggable Wiring\u003c\/td\u003e\n      \u003ctd\u003eFor all ESxxxx terminals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e12 mm x 100 mm x 68 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003eApprox. 60 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaterial\u003c\/td\u003e\n      \u003ctd\u003ePolycarbonate\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation\u003c\/td\u003e\n      \u003ctd\u003eOn 35 mm DIN rail conforming to EN 60715 with lock\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eEnvironmental and Approvals\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e95 %, no condensation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration\/Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\/Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals\/Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL, ATEX\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEx Marking\u003c\/td\u003e\n      \u003ctd\u003eII 3 G Ex nA IIC T4 Gc\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the entire control system is de-energized and locked out before performing any mechanical or electrical work.\u003c\/li\u003e\n  \u003cli\u003eInspect the terminal housing and connection points for any visible transit damage.\u003c\/li\u003e\n  \u003cli\u003eMount the BECKHOFF EL3162 onto a standard 35 mm DIN rail (EN 60715) alongside existing terminals using the double slot and key connection.\u003c\/li\u003e\n  \u003cli\u003eStrip field conductors to the specified length (8 to 9 mm) and insert solid, stranded, or ferrule-equipped wires into the spring-actuated connection points using a suitable screwdriver.\u003c\/li\u003e\n  \u003cli\u003eVerify correct potential distribution, field-side supply, and E-bus connection integrity across adjacent terminals.\u003c\/li\u003e\n  \u003cli\u003ePower on the system and verify operational status via the onboard diagnostic LEDs before initiating software configuration in TwinCAT.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106460655979,"sku":"EL3162","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/el3162-xwsymztst4l.png?v=1776244450","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-el3162-ethercat-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}