{"product_id":"beckhoff-el3202-0010-ethercat-terminal","title":"Beckhoff EL3202-0010 EtherCAT Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eFor high-precision temperature measurements in demanding automation architectures, the \u003cstrong\u003eBeckhoff EL3202-0010\u003c\/strong\u003e delivers dual-channel analog sensor integration in a highly compact form factor. This \u003cstrong\u003eEtherCAT Terminal\u003c\/strong\u003e is engineered to handle Resistance Temperature Detectors (RTD) with high resolution and absolute measurement reliability. By utilizing direct 4-wire connection technology, the module effectively eliminates signal degradation and measurement errors caused by long sensor cables, securing accurate process data for feedback control loops.\u003c\/p\u003e\n\n\u003cp\u003eThe unit receives power directly through the standard E-bus connection. Operating with a 16-bit analog-to-digital converter, it provides process temperature values down to a resolution of 0.01 Celsius per digit. An integrated configurable low-pass filter, limit monitoring, and detailed diagnostics ensure that users can tailor the terminal's performance to match specific process dynamics and harsh electrical noise environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDual-channel analog inputs dedicated to RTD and precision resistance measurements.\u003c\/li\u003e\n  \u003cli\u003eCompatible with a wide variety of temperature sensors, including Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, and KTY elements.\u003c\/li\u003e\n  \u003cli\u003e4-wire connection method for high-accuracy compensation of lead resistance.\u003c\/li\u003e\n  \u003cli\u003e16-bit digital resolution outputting 0.01 Celsius per digit.\u003c\/li\u003e\n  \u003cli\u003eConfigurable conversion times from 2 ms up to 800 ms (default setting: 85 ms).\u003c\/li\u003e\n  \u003cli\u003eBuilt-in digital filter, limit value monitoring, and integrated diagnostic LEDs.\u003c\/li\u003e\n  \u003cli\u003eSlim 12 mm housing designed for standard 35 mm DIN rail side-by-side terminal configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal processing in chemical, petrochemical, and refining facilities.\u003c\/li\u003e\n  \u003cli\u003eCritical cooling and heating loop monitoring in power plants and boiler systems.\u003c\/li\u003e\n  \u003cli\u003eHigh-accuracy environmental and test chamber monitoring.\u003c\/li\u003e\n  \u003cli\u003eFood processing pasteurization and sterilizing system controls.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBeckhoff\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEL3202-0010\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4-wire\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Filter Limit Frequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 1 kHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Support\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, resistance (e.g. potentiometer 10 Ohm to 1\/4 kOhm), KTY sensors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-200 to +850 Celsius (Pt sensors); -60 to +250 Celsius (Ni sensors); -200 to +320 Celsius (high-precision range)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.01 Celsius per digit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConversion Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eapprox. 85 ms default setting, 2 to 800 ms configurable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasuring Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; 0.5 mA (load-dependent)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasuring Error\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; +\/-0.1 Celsius at 40 Celsius ambient temperature, 4-wire connection, Pt100 sensors (-200 to +320 Celsius range) and 50 Hz filter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 V (E-bus \/ signal voltage)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003evia the E-bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption E-bus\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 190 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProcess Image Bit Width\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 x 32 bit RTD input\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e95 %, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration \/ Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity \/ Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolycarbonate\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 mm x 100 mm x 68 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eapprox. 60 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection Property\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWiring Mechanism\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSpring actuation by screwdriver\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSolid Conductor (s)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.08 to 2.5 mm² (AWG 28 to 14)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStranded Conductor (st)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.08 to 2.5 mm² (AWG 28 to 14)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFlexible Conductor with Ferrule (f)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.14 to 1.5 mm² (AWG 26 to 16)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStripping Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 to 9 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Load Power Contacts\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eImax: 10 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount securely on a standard 35 mm DIN rail (conforming to EN 60715) using the built-in locking mechanism.\u003c\/li\u003e\n  \u003cli\u003eEnsure double slot and key connection segments are properly aligned when mating adjacent terminal modules.\u003c\/li\u003e\n  \u003cli\u003eRemove power from the E-bus assembly before inserting or extracting any terminal card to protect internal communications hardware.\u003c\/li\u003e\n  \u003cli\u003eEnsure environmental guidelines are respected by installing the module in a suitable control cabinet with an IP54 or better enclosure rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n  \u003cli\u003eATEX (Ex marking: II 3 G Ex nA IIC T4 Gc)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106532647275,"sku":"EL3202-0010","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/el3202-0010-wsjnsylzbh0.png?v=1776244458","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-el3202-0010-ethercat-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}