{"product_id":"beckhoff-el4114-0020-ethercat-terminal","title":"BECKHOFF EL4114-0020 EtherCAT Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF EL4114-0020\u003c\/strong\u003e is a high-precision, 4-channel analog output EtherCAT Terminal designed for generating accurate current signals within industrial control systems. Operating in the range of 0 to 20 mA, this specialized terminal features 16-bit resolution and comes factory calibrated to ensure exceptional signal fidelity and minimal output error.\u003c\/p\u003e\n\n\u003cp\u003eCompared to standard analog output models, the \u003cstrong\u003eBECKHOFF EL4114-0020\u003c\/strong\u003e variant is optimized for demanding automation and testing environments where high-precision control loop feedback is mandatory. Its integration into the EtherCAT system allows for fast, deterministic signal transmission, making it a reliable component in multi-axis machinery and distributed process systems.\u003c\/p\u003e\n\n\u003cp\u003eWith built-in support for Distributed Clocks (DC), the terminal enables synchronized output actions across the entire network with sub-microsecond precision. The 2-wire connection layout allows for a clean, space-saving arrangement within standard terminal boxes and electrical enclosures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e4 analog output channels delivering current signals from 0 to 20 mA\u003c\/li\u003e\n  \u003cli\u003eEnhanced 16-bit signal resolution for high-accuracy setpoint adjustment\u003c\/li\u003e\n  \u003cli\u003eFactory calibrated with an individual calibration certificate included\u003c\/li\u003e\n  \u003cli\u003eDistributed Clocks (DC) compatibility for highly synchronized output updates\u003c\/li\u003e\n  \u003cli\u003eShort-circuit proof current outputs supporting loads up to 350 Ohms\u003c\/li\u003e\n  \u003cli\u003eParameterizable watchdog function to handle communication interruptions safely\u003c\/li\u003e\n  \u003cli\u003eCompact 12 mm terminal housing with integrated status LEDs\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-precision control valve and actuator positioning\u003c\/li\u003e\n  \u003cli\u003eCurrent-loop feedback signal generation for variable frequency drives\u003c\/li\u003e\n  \u003cli\u003eTest benches and simulation environments requiring precise physical signal emulation\u003c\/li\u003e\n  \u003cli\u003eProcess engineering systems requiring continuous and synchronized setpoint signals\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ch4\u003eGeneral Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eEL4114-0020\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT Terminal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Channels\u003c\/td\u003e\n      \u003ctd\u003e4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSignal Current\u003c\/td\u003e\n      \u003ctd\u003e0 to 20 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Technology\u003c\/td\u003e\n      \u003ctd\u003e2-wire, single-ended\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply\u003c\/td\u003e\n      \u003ctd\u003e24 V DC via power contacts\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption (E-Bus)\u003c\/td\u003e\n      \u003ctd\u003etyp. 160 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption (Power Contacts)\u003c\/td\u003e\n      \u003ctd\u003etyp. 15 mA + load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003e500 V (E-bus \/ signal voltage)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Load Power Contacts\u003c\/td\u003e\n      \u003ctd\u003emax. 10 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003ePerformance Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResolution\u003c\/td\u003e\n      \u003ctd\u003e16-bit (including sign)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Resistance\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; 350 Ohm (short-circuit proof)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Error\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; 0.1% (relative to end value)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Rate\u003c\/td\u003e\n      \u003ctd\u003emax. 4 ksps\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDistributed Clocks (DC)\u003c\/td\u003e\n      \u003ctd\u003eYes (precision \u0026lt;\u0026lt; 1 µs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCalibration\u003c\/td\u003e\n      \u003ctd\u003eFactory calibrated with calibration certificate\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003ePhysical and Environmental Data\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e12 mm x 100 mm x 68 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eapprox. 65 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Class\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting\u003c\/td\u003e\n      \u003ctd\u003e35 mm DIN rail (EN 60715) with lock\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the system is completely de-energized before mounting or removing the EtherCAT terminal.\u003c\/li\u003e\n  \u003cli\u003eMount the terminal on a standard 35 mm DIN rail conforming to EN 60715. Use the integrated locking mechanism and slot-and-key connection for side-by-side terminal mounting.\u003c\/li\u003e\n  \u003cli\u003eEnsure secure electrical connection via the gold-plated E-bus power contacts. Do not clean contacts with abrasive tools.\u003c\/li\u003e\n  \u003cli\u003eStrip conductors to a length of 8 to 9 mm. Terminate using solid wire, stranded wire, or wire-end ferrules through the spring actuation mechanism.\u003c\/li\u003e\n  \u003cli\u003ePerform electrical and functional testing on the signal lines before energizing the control system.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003cp\u003eWhen replacing an existing terminal with the \u003cstrong\u003eBECKHOFF EL4114-0020\u003c\/strong\u003e, verify that the 16-bit configuration and mapping match your TwinCAT process image settings, particularly if replacing a standard 12-bit output terminal. Ensure that the individual calibration requirements of your application are verified and documented with the newly supplied factory certificate details.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals\u003c\/td\u003e\n      \u003ctd\u003eCE, UL, ATEX\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEx Marking\u003c\/td\u003e\n      \u003ctd\u003eII 3 G Ex nA IIC T4 Gc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Standards\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 and EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106452595051,"sku":"EL4114-0020","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/el4114-0020-5cfz5yptcm0.png?v=1776244522","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-el4114-0020-ethercat-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}