{"product_id":"beckhoff-el6614-ethercat-terminal","title":"BECKHOFF EL6614 EtherCAT Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF EL6614\u003c\/strong\u003e is a 4-port Ethernet switch terminal designed for use within an EtherCAT Terminal system. It serves as an active, decentral communication interface that routes standard Ethernet-based traffic transparently through the terminal network without disrupting the performance or cyclic precision of the underlying EtherCAT communication. Utilizing a store-and-forward switching architecture, it ensures reliable packet delivery across all connected nodes.\u003c\/p\u003e\n\n\u003cp\u003eThis compact unit integrates external Ethernet-enabled field devices, such as industrial PCs, printers, vision sensors, and programming adapters, directly into the control environment. The \u003cstrong\u003eBECKHOFF EL6614\u003c\/strong\u003e enables a highly decentralized network layout, minimizing the need for standalone switch components in the control cabinet and streamlining localized wiring topologies.\u003c\/p\u003e\n\n\u003cp\u003eThe terminal draws its operating power entirely from the internal E-bus connection, eliminating the requirement for separate field-side load supply lines. Robust electrical isolation of 500 V between the internal E-bus and the external Ethernet lines provides reliable signal decoupling, protecting the upstream PLC system from potential field-side disturbances and ground loops.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFour RJ45 physical ports supporting 10BASE-T\/100BASE-TX Ethernet connections.\u003c\/li\u003e\n  \u003cli\u003eAutomatic setting capabilities via IEEE 802.3u auto-negotiation, enabling half or full-duplex operation at 10 or 100 Mbit\/s.\u003c\/li\u003e\n  \u003cli\u003eStore-and-forward switching mode for structured and reliable packet distribution.\u003c\/li\u003e\n  \u003cli\u003eFull, transparent compatibility with all Ethernet (IEEE 802.3)-based communication protocols.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in hardware diagnostics powered by clear status LEDs located on the front face.\u003c\/li\u003e\n  \u003cli\u003eIntegrated software features including an onboard DHCP and BootP server.\u003c\/li\u003e\n  \u003cli\u003eInherent support for Real-Time (RT) Ethernet and publisher\/subscriber network structures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized integration of standard Ethernet nodes within space-restricted control enclosures.\u003c\/li\u003e\n  \u003cli\u003eDirect network interfacing for vision systems, diagnostic terminals, and barcode scanners.\u003c\/li\u003e\n  \u003cli\u003eTemporary or permanent connection of programming adapters and engineering PCs directly to the I\/O terminal segment.\u003c\/li\u003e\n  \u003cli\u003eStandard network distribution within EtherCAT control topologies without auxiliary DIN rail switches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eEL6614\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT Terminal (Ethernet switch port)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDesign Form\u003c\/td\u003e\n      \u003ctd\u003eCompact terminal housing with diagnostic LEDs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaterial\u003c\/td\u003e\n      \u003ctd\u003ePolycarbonate\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eInterface and Communication\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Ports\u003c\/td\u003e\n      \u003ctd\u003e4 x RJ45\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePhysical Layer\u003c\/td\u003e\n      \u003ctd\u003e10BASE-T\/100BASE-TX Ethernet\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSupported Protocols\u003c\/td\u003e\n      \u003ctd\u003eAll Ethernet (IEEE 802.3)-based protocols\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003e10\/100 Mbit\/s (half or full duplex, auto-negotiation)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSwitching Architecture\u003c\/td\u003e\n      \u003ctd\u003eStore and forward switching mode\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Cable Length\u003c\/td\u003e\n      \u003ctd\u003eUp to 100 m (twisted pair)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDistributed Clocks\u003c\/td\u003e\n      \u003ctd\u003eNo\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical and Power\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply\u003c\/td\u003e\n      \u003ctd\u003eVia the E-bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption E-bus\u003c\/td\u003e\n      \u003ctd\u003eTypically 310 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption Power Contacts\u003c\/td\u003e\n      \u003ctd\u003eNone\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003e500 V (E-bus \/ Ethernet interfaces)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eEnvironmental and Mechanical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e24 mm x 100 mm x 52 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003eApprox. 95 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e95 %, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration and Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity and Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eCompliance and Safety\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals and Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL, ATEX\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEx Marking\u003c\/td\u003e\n      \u003ctd\u003eII 3 G Ex nA IIC T4 Gc\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInterface\u003c\/td\u003e\n      \u003ctd\u003eFunction\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePort 1 (RJ45)\u003c\/td\u003e\n      \u003ctd\u003eEthernet channel \/ standard network node connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePort 2 (RJ45)\u003c\/td\u003e\n      \u003ctd\u003eEthernet channel \/ standard network node connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePort 3 (RJ45)\u003c\/td\u003e\n      \u003ctd\u003eEthernet channel \/ standard network node connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePort 4 (RJ45)\u003c\/td\u003e\n      \u003ctd\u003eEthernet channel \/ standard network node connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the entire industrial control cabinet and terminal assembly are completely de-energized before mounting.\u003c\/li\u003e\n  \u003cli\u003eInstall the terminal onto a standard 35 mm DIN rail (conforming to EN 60715). Ensure the double slot and key connection with adjacent terminals is fully interlocked.\u003c\/li\u003e\n  \u003cli\u003eSecure the terminal block using appropriate mechanical end anchors to prevent lateral shifting.\u003c\/li\u003e\n  \u003cli\u003eConnect standard, shielded twisted-pair Ethernet cables equipped with RJ45 plugs directly to the physical ports, verifying that cable segments do not exceed 100 m.\u003c\/li\u003e\n  \u003cli\u003eRe-apply power to the EtherCAT network. Monitor the integrated diagnostic LEDs on the front panel to verify proper communication and power routing through the E-bus.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the system is safely shut down and power supplies to the E-bus and adjacent modules are completely isolated.\u003c\/li\u003e\n  \u003cli\u003eLabel and disconnect the Ethernet lines from the four RJ45 ports.\u003c\/li\u003e\n  \u003cli\u003eRelease the locking mechanism and dismount the terminal from the DIN rail.\u003c\/li\u003e\n  \u003cli\u003eSlide the replacement terminal onto the DIN rail, verifying clean bus contact connections.\u003c\/li\u003e\n  \u003cli\u003eReinsert the RJ45 cables into their designated ports and restore system power. Verify diagnostic LED behavior to confirm active network routing.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106469831019,"sku":"EL6614","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/el6614-e3ahehk441w.png?v=1776244551","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-el6614-ethercat-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}