{"product_id":"beckhoff-elm9410-power-supply-terminal","title":"BECKHOFF ELM9410 Power Supply Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF ELM9410\u003c\/strong\u003e is a high-performance power supply terminal designed to refresh the E-bus (EtherCAT bus) current in demanding industrial applications. Housed in a robust zinc die-cast metal enclosure, this terminal supplies up to 2 A of E-bus current (5 V DC), allowing for the extension and reliable operation of large-scale EtherCAT terminal segments. It is specifically optimized to maintain signal integrity and power stability in environments that utilize ELM-series measurement modules.\u003c\/p\u003e\n\n\u003cp\u003eTo ensure high operational reliability, the \u003cstrong\u003eBECKHOFF ELM9410\u003c\/strong\u003e features electrical isolation of up to 500 V between the E-bus, US, and UP potentials. The terminal also integrates reverse polarity protection on inputs alongside active diagnostics. Operating and supply voltage levels are monitored continuously, with diagnostic data directly written into the PLC process image for real-time status evaluation and preventive maintenance.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eReplenishes the E-bus current with an output capacity of up to 2 A (5 V DC).\u003c\/li\u003e\n  \u003cli\u003eIntegrated diagnostic monitoring of supply and output voltages reported directly in the process image.\u003c\/li\u003e\n  \u003cli\u003eRobust zinc die-cast metal housing providing high mechanical stability and signal shielding.\u003c\/li\u003e\n  \u003cli\u003eElectrical isolation of 500 V between the E-bus and field potentials.\u003c\/li\u003e\n  \u003cli\u003eReverse polarity protection to prevent damage from incorrect field wiring.\u003c\/li\u003e\n  \u003cli\u003eDirect plug-in push-in wiring for solid conductors, with easy spring actuation for stranded wires.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRefreshing the E-bus current in complex, multi-terminal EtherCAT systems.\u003c\/li\u003e\n  \u003cli\u003eSegmenting potential groups in high-accuracy ELM measurement terminal installations.\u003c\/li\u003e\n  \u003cli\u003eIndustrial test stands and automation systems requiring robust shielded enclosures and detailed power diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eELM9410\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003ePower supply terminal for refreshing the E-bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003eZinc die-cast with integrated signal LEDs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDesign Form\u003c\/td\u003e\n      \u003ctd\u003eMetal housing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation Position\u003c\/td\u003e\n      \u003ctd\u003eVariable\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical Data\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 % \/ +20 %)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Voltage\u003c\/td\u003e\n      \u003ctd\u003e5 V DC (for E-bus supply)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE-Bus Current Supply\u003c\/td\u003e\n      \u003ctd\u003e2000 mA (2 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption from US\u003c\/td\u003e\n      \u003ctd\u003e50 mA + (total E-bus current \/ 4)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption from UP\u003c\/td\u003e\n      \u003ctd\u003e50 mA + load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Contacts\u003c\/td\u003e\n      \u003ctd\u003eMax. 24 V DC \/ Max. 2 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003e500 V (E-bus \/ field potential \/ US \/ UP)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShort-Circuit Proof\u003c\/td\u003e\n      \u003ctd\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDiagnostics\u003c\/td\u003e\n      \u003ctd\u003eYes (supply and output voltage monitoring in process image)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eConnection and Wiring\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWiring Technology\u003c\/td\u003e\n      \u003ctd\u003eSolid conductors: direct plug-in; Fine-stranded: spring actuation by screwdriver\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConductor Cross-Section (Solid)\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm² (AWG 24 to 14)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConductor Cross-Section (Stranded)\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm² (AWG 24 to 14)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConductor Cross-Section (Ferrule)\u003c\/td\u003e\n      \u003ctd\u003e0.25 to 0.75 mm² (AWG 24 to 14)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStripping Length\u003c\/td\u003e\n      \u003ctd\u003e8 to 9 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMechanical and Environmental\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e30 mm x 100 mm x 95 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eApprox. 450 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting\u003c\/td\u003e\n      \u003ctd\u003e35 mm DIN rail (conforming to EN 60715) with lock\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSide-by-Side Mounting\u003c\/td\u003e\n      \u003ctd\u003eDouble slot and key connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e95 %, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\/Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem De-energization:\u003c\/strong\u003e Completely isolate and turn off all power sources supplying the terminal segment and the E-bus prior to installation or maintenance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Snap the terminal securely onto a standard 35 mm DIN rail (EN 60715). Use the integrated locking latch to fix it in place.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSide-by-Side Connection:\u003c\/strong\u003e Ensure proper engagement of the double slot and key connections when mounting adjacent ELM-series modules.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Insert solid conductors directly into the plug-in terminal connection. For fine-stranded wires or ferrules, depress the orange spring actuator using a standard flat-head screwdriver before inserting the wire. Strip wires strictly to 8–9 mm.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e Confirm that the DIN rail is properly grounded to ensure effective EMC shielding through the zinc die-cast housing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommissioning:\u003c\/strong\u003e Power on the system and verify the statuses of the diagnostic signal LEDs. Verify that the correct voltage diagnostics are visible within the TwinCAT system manager or process image.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106451743083,"sku":"ELM9410","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/elm9410-o0mxykpvecm.png?v=1776244610","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-elm9410-power-supply-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}