{"product_id":"beckhoff-ep2028-0002-ethercat-box-8-channel-digital-output-module","title":"BECKHOFF EP2028-0002 EtherCAT Box 8-Channel Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF EP2028-0002\u003c\/strong\u003e is an industrial-grade, IP67-rated EtherCAT Box designed for decentralized automation architectures. It features eight digital outputs that switch electrical loads up to 24 V DC. Engineered for direct machine mounting outside of traditional control cabinets, this module streamlines field wiring by placing digital output controls closer to the operational process.\u003c\/p\u003e\n\u003cp\u003eEach of the eight output channels in the \u003cstrong\u003eBECKHOFF EP2028-0002\u003c\/strong\u003e is individually short-circuit proof, offering enhanced field-side safety and simplified diagnostics. With a switching capacity of up to 2 A per channel (limited to a total sum current of 4 A), this EtherCAT Box is designed to drive actuators, contactors, solenoid valves, and indication lamps in demanding industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEight digital output channels supporting 24 V DC nominal voltage.\u003c\/li\u003e\n  \u003cli\u003eHigh current capacity of up to 2 A per output channel (4 A total cumulative limit).\u003c\/li\u003e\n  \u003cli\u003eIndividually short-circuit proof outputs to isolate localized wiring faults.\u003c\/li\u003e\n  \u003cli\u003eIndustrial-grade M12 (5-pin, A-coded) connectors for secure actuator interfaces.\u003c\/li\u003e\n  \u003cli\u003eEtherCAT bus interface utilizing dual shielded, screw-type M8 sockets.\u003c\/li\u003e\n  \u003cli\u003ePower feed and downstream loop-through connections via 4-pin M8 sockets.\u003c\/li\u003e\n  \u003cli\u003eHighly durable IP65, IP66, and IP67 protection rated enclosure.\u003c\/li\u003e\n  \u003cli\u003eATEX Zone 2 hazardous area compliance for explosive environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized switching of high-current solenoids, contactor coils, and valves.\u003c\/li\u003e\n  \u003cli\u003eMachine-mount control environments lacking protective electrical cabinets.\u003c\/li\u003e\n  \u003cli\u003eDistributed packaging, sorting, and material handling systems.\u003c\/li\u003e\n  \u003cli\u003eExplosion-protected industrial operations requiring ATEX-certified field devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel Number\u003c\/td\u003e\n      \u003ctd\u003eEP2028-0002\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT Box (Digital Output)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n      \u003ctd\u003e8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax. Output Current\u003c\/td\u003e\n      \u003ctd\u003e2 A per channel (individually short-circuit proof, total sum 4 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Types Supported\u003c\/td\u003e\n      \u003ctd\u003eOhmic, inductive, lamp load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTypical Short-Circuit Current\u003c\/td\u003e\n      \u003ctd\u003e15 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTypical Switching Times\u003c\/td\u003e\n      \u003ctd\u003eTON: 200 microseconds, TOFF: 200 microseconds\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface Connection\u003c\/td\u003e\n      \u003ctd\u003e2 x M8 sockets, shielded, screw type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Connections\u003c\/td\u003e\n      \u003ctd\u003eM12, 5-pin, A-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Feed\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 male socket, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDownstream Power Connection\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 female socket, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption (from US)\u003c\/td\u003e\n      \u003ctd\u003e120 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAuxiliary Power Current (from UP)\u003c\/td\u003e\n      \u003ctd\u003eTyp. 20 mA + load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003e500 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration\/Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\/Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Class\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals and Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL, ATEX\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEx Marking\u003c\/td\u003e\n      \u003ctd\u003eII 3 G Ex nA IIC T4 Gc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eApprox. 165 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the system power supply is completely de-energized before mounting or handling the module.\u003c\/li\u003e\n  \u003cli\u003eMount the EtherCAT Box securely to a flat surface using the integrated mounting holes to prevent mechanical stress or vibration issues.\u003c\/li\u003e\n  \u003cli\u003eConnect the EtherCAT incoming and outgoing network lines to the shielded M8 screw connectors. Secure the screw-type connections to maintain the specified IP protection level.\u003c\/li\u003e\n  \u003cli\u003eWire the 24 V DC power supply feed to the 4-pin male M8 connector. If feeding downstream boxes, connect the downstream cable to the 4-pin female M8 connector.\u003c\/li\u003e\n  \u003cli\u003eAttach the actuator cables to the A-coded, 5-pin M12 sockets. Use protective caps on any unused ports to prevent environmental ingress.\u003c\/li\u003e\n  \u003cli\u003eEnsure proper grounding practices are followed to prevent electromagnetic interference.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eDisconnect all electrical power sources and control signals from the module before starting the replacement process.\u003c\/li\u003e\n  \u003cli\u003eCarefully record the port assignments and physical cabling layout of all M8 and M12 connections prior to removal.\u003c\/li\u003e\n  \u003cli\u003eReplace the faulty module with an identical \u003cstrong\u003eBECKHOFF EP2028-0002\u003c\/strong\u003e module.\u003c\/li\u003e\n  \u003cli\u003eReconnect the cables to their designated ports, ensuring all screw locks are tightened securely.\u003c\/li\u003e\n  \u003cli\u003eVerify the EtherCAT configuration matches the device's revision in TwinCAT before resuming live operations.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106541265259,"sku":"EP2028-0002","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ep2028-0002-dsazqrpkeaf.png?v=1776244646","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ep2028-0002-ethercat-box-8-channel-digital-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}