{"product_id":"beckhoff-ep2816-0010-ethercat-box-16-channel-digital-output-module","title":"BECKHOFF EP2816-0010 EtherCAT Box 16-Channel Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for decentralized automation tasks requiring dense digital output distribution directly in the field, the Beckhoff \u003cstrong\u003eEP2816-0010\u003c\/strong\u003e \u003cstrong\u003eEtherCAT Box\u003c\/strong\u003e provides 16 digital outputs in a robust, space-saving enclosure. This IP65\/66\/67-rated module connects binary control signals from the EtherCAT network directly to actuators and devices, eliminating the need for protective control cabinets and minimizing complex field cabling.\u003c\/p\u003e\n\n\u003cp\u003eFeaturing two 9-pin D-sub socket connections, this module is specifically optimized for direct, hassle-free interfaces with multi-pin connector valve terminals and pneumatic manifold systems. The outputs support ohmic, inductive, and lamp loads with integrated short-circuit protection and electrical isolation up to 500 V, making it highly reliable in demanding manufacturing and process environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e16 digital output channels in a highly compact, direct-to-field mountable housing.\u003c\/li\u003e\n  \u003cli\u003eEquipped with two 9-pin D-sub socket connectors tailored for multi-pin valve manifolds.\u003c\/li\u003e\n  \u003cli\u003eIndividually short-circuit proof outputs with 0.5 A maximum output current per channel.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Distributed Clocks functionality for precise synchronization across the EtherCAT network.\u003c\/li\u003e\n  \u003cli\u003eRugged environmental design with IP65, IP66, and IP67 ingress protection ratings.\u003c\/li\u003e\n  \u003cli\u003eEtherCAT communication interface utilizing shielded, screw-type M8 sockets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect integration with pneumatic valve terminals and manifold systems.\u003c\/li\u003e\n  \u003cli\u003eDecentralized actuator control in automotive assembly and robotic lines.\u003c\/li\u003e\n  \u003cli\u003eField-level I\/O processing in material handling and packaging systems.\u003c\/li\u003e\n  \u003cli\u003eGeneral manufacturing automation requiring direct, cabinet-free mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBeckhoff\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\/Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEP2816-0010\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5 A per channel (individually short-circuit proof, total limit 4.0 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShort-Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMax. 1.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLoad Types\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOhmic, inductive, lamp load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSwitching Times (Typical)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eT ON: 60 us, T OFF: 300 us\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption (Us)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e120 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAuxiliary Power Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTyp. 20 mA + load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDistributed Clocks\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration \/ Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity \/ Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP65 \/ IP66 \/ IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApprox. 165 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection Type\u003c\/th\u003e\n      \u003cth\u003eInterface Style\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBus Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 x M8 socket, shielded, screw type\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT input and downstream extension\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Connections\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 x D-sub socket, 9-pin\u003c\/td\u003e\n      \u003ctd\u003e16 digital outputs for actuator\/valve terminals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Feed\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 male socket, 4-pin\u003c\/td\u003e\n      \u003ctd\u003eIncoming control and auxiliary power (Us\/Up)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Downstream\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 female socket, 4-pin\u003c\/td\u003e\n      \u003ctd\u003ePower distribution loop-through to adjacent modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install directly onto flat machine structures or profiles using integrated mounting holes. Variable mounting positions are supported.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding \u0026amp; Grounding:\u003c\/strong\u003e Ensure proper connection of the shielded M8 EtherCAT cables to achieve reliable grounding and maintain full EMC compliance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Keep communication cabling and high-power actuator lines separated where possible to avoid electrical interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e To maintain the IP65\/66\/67 protection rating, ensure all unused M8 and D-sub ports are sealed with appropriate protective caps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106488705387,"sku":"EP2816-0010","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ep2816-0010-5t4zqzrro3b.png?v=1776244665","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ep2816-0010-ethercat-box-16-channel-digital-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}