{"product_id":"beckhoff-ep9224-0037-ethercat-box-power-distributor","title":"BECKHOFF EP9224-0037 EtherCAT Box Power Distributor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF EP9224-0037\u003c\/strong\u003e is an IP67-rated EtherCAT Box designed for robust power distribution, branching, and diagnostics within EtherCAT P networks. It serves as an active EtherCAT P junction, enabling the safe feed-in, loop-through, and branch routing of Us (system and sensor power) and Up (peripheral voltage for actuators). By utilizing robust B17 ENP connectors with a secure bayonet fitting, this module distributes incoming power to downstream devices while continuously monitoring the electrical parameters of each branch.\u003c\/p\u003e\n\n\u003cp\u003eIntegrated measurement circuitry in the \u003cstrong\u003eBECKHOFF EP9224-0037\u003c\/strong\u003e tracks the input voltages, input currents, and individual output currents for all channels. This diagnostic information is transmitted directly via process data to the master controller, allowing for rapid overload detection and localized isolation. In the event of a system fault or power failure, internal data logging capabilities record relevant diagnostic data to simplify troubleshooting and maintenance workflows.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eActive EtherCAT P power distribution and topology junction.\u003c\/li\u003e\n  \u003cli\u003eB17 ENP shielded connections featuring a secure bayonet fitting.\u003c\/li\u003e\n  \u003cli\u003eOne ENP B17 input, one ENP B17 feedthrough, and four M8 P-coded EtherCAT P output channels.\u003c\/li\u003e\n  \u003cli\u003eContinuous voltage and current monitoring for Us and Up paths.\u003c\/li\u003e\n  \u003cli\u003eInternal data logging functionality for capturing event data during electrical failures.\u003c\/li\u003e\n  \u003cli\u003eReal-time diagnostic feedback transmitted directly through standard process data.\u003c\/li\u003e\n  \u003cli\u003eIP67-rated enclosure suitable for cabinet-free field installations in demanding environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized power routing and branch topology creation in modular machinery.\u003c\/li\u003e\n  \u003cli\u003eFieldbus system distribution requiring high-current power transmission and localized diagnostic feedback.\u003c\/li\u003e\n  \u003cli\u003eStar-topology configuration adjustments within complex EtherCAT P industrial networks.\u003c\/li\u003e\n  \u003cli\u003eCabinet-free machine setups requiring IP67 protection against liquids and dust.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eEP9224-0037\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT P Junction and Power Distributor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtocol\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Channels\u003c\/td\u003e\n      \u003ctd\u003e1 x ENP IN, 1 x ENP OUT (Feedthrough), 4 x EtherCAT P OUT\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical Data\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInfeed Connector\u003c\/td\u003e\n      \u003ctd\u003eENP B17, 5-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Infeed Current\u003c\/td\u003e\n      \u003ctd\u003e15.5 A per Us \/ Up at 45 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Feedthrough Connector\u003c\/td\u003e\n      \u003ctd\u003eENP B17, 5-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Feedthrough Current\u003c\/td\u003e\n      \u003ctd\u003e15.5 A per Us \/ Up at 45 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Rating per Output Port\u003c\/td\u003e\n      \u003ctd\u003eMax. 3.0 A per Us and Up (M8 P-coded)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDiagnostic Features\u003c\/td\u003e\n      \u003ctd\u003eInput voltages\/currents, individual output currents via process data\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Logging\u003c\/td\u003e\n      \u003ctd\u003eFailure-related status recording\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003ePhysical and Environmental\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e2 x B17 ENP, shielded, bayonet fitting\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIP Protection Class\u003c\/td\u003e\n      \u003ctd\u003eIP67\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity and Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 and EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals and Markings\u003c\/td\u003e\n      \u003ctd\u003eCE\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface \/ Connector\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eENP IN (B17, 5-pin)\u003c\/td\u003e\n      \u003ctd\u003ePower infeed (Us \/ Up) and incoming EtherCAT communication link\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eENP OUT (B17, 5-pin)\u003c\/td\u003e\n      \u003ctd\u003eHigh-current power feedthrough loop and outgoing EtherCAT communication link\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEtherCAT P OUT 1 to 4 (M8, P-coded)\u003c\/td\u003e\n      \u003ctd\u003eDistributed EtherCAT P outputs with independent monitoring (Max. 3.0 A per port)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the supply power to all feed cables is fully de-energized before beginning installation.\u003c\/li\u003e\n  \u003cli\u003eVerify that the physical mounting location is clean, flat, and allows appropriate cable bend radiuses for the B17 and M8 connectors.\u003c\/li\u003e\n  \u003cli\u003eSecurely mount the module using the integrated mounting holes on the outer casing.\u003c\/li\u003e\n  \u003cli\u003eConnect the incoming B17 ENP power and communication cable to the ENP IN port. Tighten the bayonet coupling fully to ensure an IP67 seal.\u003c\/li\u003e\n  \u003cli\u003eConnect the feedthrough or branched M8 P-coded cables to the respective downstream devices. Ensure unused ports are fitted with appropriate IP67 protection caps.\u003c\/li\u003e\n  \u003cli\u003eEstablish continuous grounding and shield connections across all connected interfaces.\u003c\/li\u003e\n  \u003cli\u003eEnergize the system and verify the status LEDs illuminate, indicating correct bus communication and power distribution states.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003cp\u003eWhen replacing a \u003cstrong\u003eBECKHOFF EP9224-0037\u003c\/strong\u003e module, document and label all connected M8 and B17 cabling before removal to prevent mismating during reinstallation. Ensure that downstream load profiles do not exceed the 3.0 A per-port limit or the aggregate 15.5 A limit on the replacement unit. Verify that the correct hardware revision and configuration profiles are active in your TwinCAT system manager after mounting the replacement unit.\u003c\/p\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106449514859,"sku":"EP9224-0037","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ep9224-0037-hawajbimuyc.png?v=1776244695","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ep9224-0037-ethercat-box-power-distributor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}