{"product_id":"beckhoff-epi2339-0022-io-link-box-module","title":"BECKHOFF EPI2339-0022 IO-Link Box Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF EPI2339-0022\u003c\/strong\u003e is a field-level IO-Link box module equipped with 16 digital channels that can be individually configured as inputs or outputs. This Class B IO-Link device facilitates high-speed data transmission up to 230.4 kbaud (COM 3) based on the IO-Link V1.1 specification. Designed for decentralized installation in demanding environmental conditions, it eliminates the need for protective control cabinets by providing high ingress protection directly on the machine frame.\u003c\/p\u003e\n\u003cp\u003eEach of the 16 channels can be adapted dynamically to function either as a Type 3 digital input or as a 0.5 A digital output. The inputs feature adjustable filter settings, while the short-circuit proof outputs are rated to handle resistive, inductive, and lamp loads. Power is distributed through the L+ and P24 supplies with integrated electrical isolation to maintain safe operational boundaries between logic and actuator lines.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e16 digital channels individually configurable as inputs or outputs\u003c\/li\u003e\n  \u003cli\u003eIO-Link V1.1 Class B compliance for higher power availability and communication\u003c\/li\u003e\n  \u003cli\u003eSupports COM 3 communication rate of 230.4 kbaud\u003c\/li\u003e\n  \u003cli\u003eAdjustable input filter time from 0 to 20 ms to suppress signal noise\u003c\/li\u003e\n  \u003cli\u003e0.5 A output current per channel with short-circuit protection and 4 A maximum total sum current\u003c\/li\u003e\n  \u003cli\u003eM12 screw-type connections for reliable field-level wiring\u003c\/li\u003e\n  \u003cli\u003eElectrical isolation between logic supply (L+) and actuator\/load supply (P24)\u003c\/li\u003e\n  \u003cli\u003eConstructed from durable polyamide (PA6) housing material\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized input\/output collection on field-level machinery\u003c\/li\u003e\n  \u003cli\u003eConnection of sensors and actuators in packaging and assembly systems\u003c\/li\u003e\n  \u003cli\u003eDistributed digital control in material handling and conveyor setups\u003c\/li\u003e\n  \u003cli\u003eSpace-constrained installations requiring fieldbus-independent I\/O expansion\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEPI2339-0022\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 plug, A-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIO-Link V1.1, Class B\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Transfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e230.4 kbaud (COM 3)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16 digital inputs or outputs, configurable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eI\/O Connection Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM12, screw type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Filter Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.0 ms (default), adjustable from 0 to 20 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e\"0\" Signal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-3 to +5 V (EN 61131-2, type 3)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e\"1\" Signal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e11 to 30 V (EN 61131-2, type 3)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 3 mA (EN 61131-2, type 3)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFrom P24, max. 0.5 A total, short-circuit proof\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLoad Type Support\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOhmic, inductive, lamp load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Load Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5 A per channel from P24, individually short-circuit proof, total max. 4 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShort-Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003emax. 1.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLogic Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 100 mA from L+\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAuxiliary Power Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 20 mA + load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eYes (between L+ and P24)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyamide (PA6)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e60 mm x 126 mm x 26.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eapprox. 250 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM12 Plug (A-coded)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIO-Link connection, including logic supply (L+) and auxiliary power (P24)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM12 Sockets\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDigital input and output channel connections for sensors and actuators\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure all electrical power sources are safely disconnected and locked out before starting the physical installation.\u003c\/li\u003e\n  \u003cli\u003eInspect the BECKHOFF EPI2339-0022 unit for any signs of physical damage before mounting.\u003c\/li\u003e\n  \u003cli\u003eMount the module directly to the machine structure using the integrated 3.5 mm mounting holes (for M3 screws) or the 4.5 mm mounting holes (for M4 screws).\u003c\/li\u003e\n  \u003cli\u003eConnect the IO-Link interface using a compatible, shielded M12 A-coded cable.\u003c\/li\u003e\n  \u003cli\u003eSecurely tighten all M12 field connections to preserve the IP65\/66\/67 rating. Install protective sealing caps on any unused ports.\u003c\/li\u003e\n  \u003cli\u003eApply power and configure the module directions (inputs vs. outputs) and filter parameters in your system configuration software.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106500043115,"sku":"EPI2339-0022","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/epi2339-0022-dloguix2fdq.png?v=1776244704","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-epi2339-0022-io-link-box-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}