{"product_id":"beckhoff-epp3314-0002-ethercat-p-box","title":"BECKHOFF EPP3314-0002 EtherCAT P Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF \u003cstrong\u003eEPP3314-0002\u003c\/strong\u003e is a 4-channel thermocouple EtherCAT P Box designed for precise temperature measurement in industrial automation environments. This robust IP65\/66\/67 rated module acquires signals directly from industrial thermocouples and millivolt sources, transmitting the digitized data via the high-speed EtherCAT network. It integrates into decentralized machine topologies without requiring a control cabinet.\u003c\/p\u003e\n\u003cp\u003eEquipped with M12 connection technology for 2-wire thermocouple sensors and M8 sockets for EtherCAT P communication, the EPP3314-0002 combines power supply and communication in a single cable. It supports a wide array of thermocouple types and features configurable input filters and open-circuit recognition to ensure reliable process monitoring.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFour thermocouple input channels supporting multiple sensor types and mV measurements\u003c\/li\u003e\n  \u003cli\u003eEtherCAT P communication interface combining real-time Ethernet data transmission and 24 V DC system\/sensor supply in one cable\u003c\/li\u003e\n  \u003cli\u003eConfigurable input filter settings for optimized signal processing\u003c\/li\u003e\n  \u003cli\u003eIntegrated open-circuit recognition for enhanced diagnostic capability\u003c\/li\u003e\n  \u003cli\u003eRugged industrial housing with IP65, IP66, and IP67 protection ratings for direct machine mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDistributed temperature acquisition in machine building and factory automation\u003c\/li\u003e\n  \u003cli\u003eThermal process monitoring and environmental testing systems\u003c\/li\u003e\n  \u003cli\u003eConveyor and handling equipment requiring cabinet-free I\/O architecture\u003c\/li\u003e\n  \u003cli\u003eIndustrial machinery operating in harsh environments exposed to dust, moisture, and cleaning agents\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eEPP3314-0002\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT P Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtocol\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eSignal and I\/O\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e4 channels (thermocouple or mV measurement)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Types\u003c\/td\u003e\n      \u003ctd\u003eTypes J, K, L, B, E, N, R, S, T, U (default setting type K), mV measurement\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMeasuring Range\u003c\/td\u003e\n      \u003ctd\u003eDepending on sensor type; preset value is type K, -100 to +1370 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResolution\u003c\/td\u003e\n      \u003ctd\u003e0.1 degC per digit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMeasurement Error \/ Uncertainty\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; ±0.3 % for type K (relative to full scale value)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConversion Time\u003c\/td\u003e\n      \u003ctd\u003e2.5 s down to 20 ms (default: approx. 250 ms)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Filter\u003c\/td\u003e\n      \u003ctd\u003e5 variations, configurable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSpecial Features\u003c\/td\u003e\n      \u003ctd\u003eOpen-circuit recognition\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 % \/ +20 %)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption from US\u003c\/td\u003e\n      \u003ctd\u003eTyp. 100 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003e500 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eConnection\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e2 x M8 socket, shielded, screw type, P-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Method (Sensors)\u003c\/td\u003e\n      \u003ctd\u003eM12 screw type for 2-wire connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMechanical and Environmental\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation Position\u003c\/td\u003e\n      \u003ctd\u003eVariable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration \/ Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity \/ Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003eApprox. 165 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the system is completely de-energized before mounting or wiring the module.\u003c\/li\u003e\n  \u003cli\u003eVerify that the mounting surface is clean and mechanically stable to support the module and connected cables.\u003c\/li\u003e\n  \u003cli\u003eMount the EPP3314-0002 securely using appropriate fasteners in the desired installation position.\u003c\/li\u003e\n  \u003cli\u003eConnect the EtherCAT P line using shielded P-coded M8 cables to ensure proper data communication and power supply.\u003c\/li\u003e\n  \u003cli\u003eConnect the thermocouple sensors to the M12 ports using correct polarity and compatible 2-wire cabling.\u003c\/li\u003e\n  \u003cli\u003eCheck all connections, cable shielding, and potential grounding before restoring power to the system.\u003c\/li\u003e\n  \u003cli\u003eConfigure the input channels and sensor types within the TwinCAT engineering environment prior to commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106473140587,"sku":"EPP3314-0002","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/epp3314-0002-pbb2yyksf1d.png?v=1776244751","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-epp3314-0002-ethercat-p-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}