{"product_id":"beckhoff-er8309-1022-ethercat-box","title":"BECKHOFF ER8309-1022 EtherCAT Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF ER8309-1022\u003c\/strong\u003e is a multi-functional EtherCAT Box designed for direct field installation in demanding industrial environments. By integrating a versatile combination of digital, analog, and specialized current-controlled pulse-width modulation (PWMi) channels into a single, compact unit, this module enables decentralized physical signal acquisition and control without requiring an electrical control cabinet.\u003c\/p\u003e\n\u003cp\u003eThe unit establishes direct communication with an EtherCAT industrial network through shielded M8 screw-type connectors, maintaining signal integrity and high transmission rates. Its specialized architecture combines digital inputs\/outputs, standard current analog inputs, an analog output, and a high-frequency PWMi output to handle complex field devices like proportional valves, sensors, and actuators from a single decentralized point.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHighly integrated multi-signal processing, minimizing the requirement for separate specialized I\/O boxes.\u003c\/li\u003e\n  \u003cli\u003e8 digital channels that are individually configurable as either inputs or outputs.\u003c\/li\u003e\n  \u003cli\u003e2 single-ended analog inputs supporting standard 0 to 20 mA or 4 to 20 mA operational ranges with 12-bit resolution.\u003c\/li\u003e\n  \u003cli\u003e1 single-ended analog output supporting 0 to 20 mA or 4 to 20 mA signals with 12-bit resolution.\u003c\/li\u003e\n  \u003cli\u003e1 current-controlled PWMi output capable of delivering up to 1.2 A at a maximum frequency of 30 kHz, optimal for proportional valve applications.\u003c\/li\u003e\n  \u003cli\u003ePhysical environmental protection rating of IP65, IP66, and IP67 when fully connected and mated.\u003c\/li\u003e\n  \u003cli\u003eDedicated sensor supply sourced from the control voltage (Us) and actuator\/load supply sourced from the auxiliary voltage (Up).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized machine mounting and remote field-level signal acquisition.\u003c\/li\u003e\n  \u003cli\u003eHydraulic and pneumatic system control utilizing current-controlled proportional valves.\u003c\/li\u003e\n  \u003cli\u003eProcess monitoring involving analog pressure, flow, and temperature transmitters.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling systems and machinery operating in wet, dusty, or high-vibration conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel Number\u003c\/td\u003e\n      \u003ctd\u003eER8309-1022\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtocol\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e2 x M8 socket, shielded, screw type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSignal Connection\u003c\/td\u003e\n      \u003ctd\u003eM12, screw type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Channels\u003c\/td\u003e\n      \u003ctd\u003e8 digital inputs or outputs (channels 6 to 13)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Input Filter\u003c\/td\u003e\n      \u003ctd\u003e3 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLimit Frequency\u003c\/td\u003e\n      \u003ctd\u003e2.5 kHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n      \u003ctd\u003e2, single-ended, 12-bit, 0\/4 to 20 mA (channels 0 and 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n      \u003ctd\u003e1, single-ended, 12-bit, 0\/4 to 20 mA (channel 15)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePWMi Outputs\u003c\/td\u003e\n      \u003ctd\u003e1 x 1.2 A, max. 30 kHz (channel 14)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMeasurement Uncertainty (Input)\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; 0.3% (relative to full scale value)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMeasurement Uncertainty (Output)\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; 0.1% (relative to full scale value)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Supply\u003c\/td\u003e\n      \u003ctd\u003eDerived from control voltage Us\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eActuator Supply\u003c\/td\u003e\n      \u003ctd\u003eDerived from auxiliary voltage Up\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003e500 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Class\u003c\/td\u003e\n      \u003ctd\u003eIP65\/66\/67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eApprox. 450 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface or Terminal\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEtherCAT Port In\u003c\/td\u003e\n      \u003ctd\u003eM8 shielded female connector, network input\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEtherCAT Port Out\u003c\/td\u003e\n      \u003ctd\u003eM8 shielded female connector, network output to next station\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUs \/ Up Feed\u003c\/td\u003e\n      \u003ctd\u003eM8 male connector for control voltage (Us) and auxiliary power (Up)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eI\/O Channels\u003c\/td\u003e\n      \u003ctd\u003eM12 screw-type female sockets for digital, analog, and PWM signal lines\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the physical part number on the unit matches your system configuration requirements.\u003c\/li\u003e\n  \u003cli\u003eEnsure all power sources, including control voltage (Us) and auxiliary load voltage (Up), are completely de-energized before mounting or connecting.\u003c\/li\u003e\n  \u003cli\u003eMount the EtherCAT Box securely onto a flat machine surface using appropriate fastening screws. Ensure the installation position aligns with your system drainage and cable routing plans.\u003c\/li\u003e\n  \u003cli\u003eConnect the incoming and outgoing EtherCAT cables to the M8 communication sockets. Hand-tighten the screw collars to ensure proper sealing.\u003c\/li\u003e\n  \u003cli\u003eWire the sensors, actuators, and analog connections to the respective M12 sockets. Use shielded cables where necessary, especially for analog input\/output and PWMi channels, to prevent electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003eEnsure all unused M8 and M12 sockets are sealed with protective caps to maintain the IP65\/66\/67 environmental rating.\u003c\/li\u003e\n  \u003cli\u003eApply Us and Up voltages, check status LEDs for correct system boot, and proceed with TwinCAT system configuration and scan.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis product conforms to the relevant European directives and standards, carrying the following markings:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106430280043,"sku":"ER8309-1022","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/er8309-1022-jh2jse4sp55.png?v=1776244812","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-er8309-1022-ethercat-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}